Miklós Szakáll

Dr. Miklós Szakáll

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2018 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
PDPaul J. DeMott
Paul J. DeMott
OMOttmar Möhler
Ottmar Möhler
DCDaniel J. Cziczo
Daniel J. Cziczo
Naruki HiranumaNaruki Hiranuma
Naruki Hiranuma
MPMarkus D. Petters
Markus D. Petters
JZJake Zenker
Jake Zenker
The second phase of the Fifth International Ice Nucleation Workshop (FIN-02) involved the gathering of a large number of researchers at the Karlsruhe Institute of Technology's Aerosol Interactions and Dynamics of the Atmosphere (AIDA) facility to promote characterization and understanding of ice nucleation measurements made by a variety of methods used worldwide. Compared to the previous workshop in 2007, participation was doubled, reflecting a vibrant research area. Experimental methods involved sampling of aerosol particles by direct processing ice nucleation measuring systems from the same volume of air in separate experiments using different ice nucleating particle (INP) types, and collections of aerosol particle samples onto filters or into liquid for sharing amongst measurement techniques that post-process these samples. In this manner, any errors introduced by differences in generation methods when samples are shared across laboratories were mitigated. Furthermore, as much as possible, aerosol particle size distribution was controlled so that the size limitations of different methods were minimized. The results presented here use data from the workshop to assess the comparability of immersion freezing measurement methods activating INPs in bulk suspensions, methods that activate INPs in condensation and/or immersion freezing modes as single particles on a substrate, continuous flow diffusion chambers (CFDCs) directly sampling and processing particles well above water saturation to maximize immersion and subsequent freezing of aerosol particles, and expansion cloud chamber simulations in which liquid cloud droplets were first activated on aerosol particles prior to freezing. The AIDA expansion chamber measurements are expected to be the closest representation to INP activation in atmospheric cloud parcels in these comparisons, due to exposing particles freely to adiabatic cooling. The different particle types used as INPs included the minerals illite NX and potassium feldspar (K-feldspar), two natural soil dusts representative of arable sandy loam (Argentina) and highly erodible sandy dryland (Tunisia) soils, respectively, and a bacterial INP (Snomax®). Considered together, the agreement among post-processed immersion freezing measurements of the numbers and fractions of particles active at different temperatures following bulk collection of particles into liquid was excellent, with possible temperature uncertainties inferred to be a key factor in determining INP uncertainties. Collection onto filters for rinsing versus directly into liquid in impingers made little difference. For methods that activated collected single particles on a substrate at a controlled humidity at or above water saturation, agreement with immersion freezing methods was good in most cases, but was biased low in a few others for reasons that have not been resolved, but could relate to water vapor competition effects. Amongst CFDC-style instruments, various factors requiring (variable) higher supersaturations to achieve equivalent immersion freezing activation dominate the uncertainty between these measurements, and for comparison with bulk immersion freezing methods. When operated above water saturation to include assessment of immersion freezing, CFDC measurements often measured at or above the upper bound of immersion freezing device measurements, but often underestimated INP concentration in comparison to an immersion freezing method that first activates all particles into liquid droplets prior to cooling (the PIMCA-PINC device, or Portable Immersion Mode Cooling chAmber–Portable Ice Nucleation Chamber), and typically slightly underestimated INP number concentrations in comparison to cloud parcel expansions in the AIDA chamber; this can be largely mitigated when it is possible to raise the relative humidity to sufficiently high values in the CFDCs, although this is not always possible operationally. Correspondence of measurements of INPs among direct sampling and post-processing systems varied depending on the INP type. Agreement was best for Snomax® particles in the temperature regime colder than −10 ∘C, where their ice nucleation activity is nearly maximized and changes very little with temperature. At temperatures warmer than −10 ∘C, Snomax® INP measurements (all via freezing of suspensions) demonstrated discrepancies consistent with previous reports of the instability of its protein aggregates that appear to make it less suitable as a calibration INP at these temperatures. For Argentinian soil dust particles, there was excellent agreement across all measurement methods; measures ranged within 1 order of magnitude for INP number concentrations, active fractions and calculated active site densities over a 25 to 30 ∘C range and 5 to 8 orders of corresponding magnitude change in number concentrations. This was also the case for all temperatures warmer than −25 ∘C in Tunisian dust experiments. In contrast, discrepancies in measurements of INP concentrations or active site densities that exceeded 2 orders of magnitude across a broad range of temperature measurements found at temperatures warmer than −25 ∘C in a previous study were replicated for illite NX. Discrepancies also exceeded 2 orders of magnitude at temperatures of −20 to −25 ∘C for potassium feldspar (K-feldspar), but these coincided with the range of temperatures at which INP concentrations increase rapidly at approximately an order of magnitude per 2 ∘C cooling for K-feldspar. These few discrepancies did not outweigh the overall positive outcomes of the workshop activity, nor the future utility of this data set or future similar efforts for resolving remaining measurement issues. Measurements of the same materials were repeatable over the time of the workshop and demonstrated strong consistency with prior studies, as reflected by agreement of...

1 September 2010 in Atmospheric Research
Verified
Journal Article
Closed access
MSMiklós Szakáll
Miklós Szakáll
SMSubir K. Mitra
Subir K. Mitra
KDKaroline Diehl
Karoline Diehl
SBStephan Borrmann
Stephan Borrmann

10 April 2019 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
Naruki HiranumaNaruki Hiranuma
Naruki Hiranuma
KAKouji Adachi
Kouji Adachi
DBDavid Bell
David Bell
FBFranco Belosi
Franco Belosi
HBHassan Beydoun
Hassan Beydoun
OMOttmar Möhler
Ottmar Möhler
We present the laboratory results of immersion freezing efficiencies of cellulose particles at supercooled temperature (T) conditions. Three types of chemically homogeneous cellulose samples are used as surrogates that represent supermicron and submicron ice-nucleating plant structural polymers. These samples include microcrystalline cellulose (MCC), fibrous cellulose (FC) and nanocrystalline cellulose (NCC). Our immersion freezing dataset includes data from various ice nucleation measurement techniques available at 17 different institutions, including nine dry dispersion and 11 aqueous suspension techniques. With a total of 20 methods, we performed systematic accuracy and precision analysis of measurements from all 20 measurement techniques by evaluating T-binned (1 ∘C) data over a wide T range (−36 ∘C <T<-4 ∘C). Specifically, we intercompared the geometric surface area-based ice nucleation active surface site (INAS) density data derived from our measurements as a function of T, ns,geo(T). Additionally, we also compared the ns,geo(T) values and the freezing spectral slope parameter (Δlog(ns,geo)/ΔT) from our measurements to previous literature results. Results show all three cellulose materials are reasonably ice active. The freezing efficiencies of NCC samples agree reasonably well, whereas the diversity for the other two samples spans ≈ 10 ∘C. Despite given uncertainties within each instrument technique, the overall trend of the ns,geo(T) spectrum traced by the T-binned average of measurements suggests that predominantly supermicron-sized cellulose particles (MCC and FC) generally act as more efficient ice-nucleating particles (INPs) than NCC with about 1 order of magnitude higher ns,geo(T).

1 March 2009 in Journal of the Atmospheric Sciences
Verified
Journal Article
Open access
MSMiklós Szakáll
Miklós Szakáll
KDKaroline Diehl
Karoline Diehl
SMSubir K. Mitra
Subir K. Mitra
SBStephan Borrmann
Stephan Borrmann
Precipitation prediction using weather radars requires detailed knowledge of the shape parameters of raindrops falling at their terminal velocities in air. Because the raindrops undergo oscillation, the most important shape parameters from the radar prediction point of view are the equilibrium drop shape, the time-averaged axis ratio, and the oscillation frequency. These parameters for individual water drops with equivalent diameter from 2.5 to 7.5 mm were investigated in a vertical wind tunnel using high-speed video imaging. A very good agreement was found between the measured and the theoretically determined raindrop shape calculated by a force balance model. A new method was developed to determine the equivalent drop diameter with the help of the oscillation frequency. The drop size determination by means of the frequency method was found to be three times more precise than by volumetric methods. The time-averaged axis ratio was found to be equal to the equilibrium axis ratio in the investigated raindrop size range. The analysis of the oscillation frequency of the raindrops revealed that the drops undergo multimode oscillations and are oscillating in a transverse mode in addition to an axisymmetric oblate–prolate mode. Experiments are included in which the internal circulation associated with drop oscillation was investigated and compared to theory.

20 October 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
RWRalf Weigel
Ralf Weigel
PSPeter Spichtinger
Peter Spichtinger
CMChristoph Mahnke
Christoph Mahnke
MKMarcus Klingebiel
Marcus Klingebiel
AAArmin Afchine
Armin Afchine
SBStephan Borrmann
Stephan Borrmann
Particle concentration measurements with underwing probes on aircraft are impacted by air compression upstream of the instrument body as a function of flight velocity. In particular, for fast-flying aircraft the necessity arises to account for compression of the air sample volume. Hence, a correction procedure is needed to invert measured particle number concentrations to ambient conditions that is commonly applicable to different instruments to gain comparable results. In the compression region where the detection of particles occurs (i.e. under factual measurement conditions), pressure and temperature of the air sample are increased compared to ambient (undisturbed) conditions in certain distance away from the aircraft. Conventional procedures for scaling the measured number densities to ambient conditions presume that the air volume probed per time interval is determined by the aircraft speed (true air speed, TAS). However, particle imaging instruments equipped with pitot tubes measuring the probe air speed (PAS) of each underwing probe reveal PAS values systematically below those of the TAS. We conclude that the deviation between PAS and TAS is mainly caused by the compression of the probed air sample. From measurements during two missions in 2014 with the German Gulfstream G-550 (HALO – High Altitude LOng range) research aircraft we develop a procedure to correct the measured particle concentration to ambient conditions using a thermodynamic approach. With the provided equation, the corresponding concentration correction factor ξ is applicable to the high-frequency measurements of the underwing probes, each of which is equipped with its own air speed sensor (e.g. a pitot tube). ξ values of 1 to 0.85 are calculated for air speeds (i.e. TAS) between 60 and 250 m s−1. For different instruments at individual wing position the calculated ξ values exhibit strong consistency, which allows for a parameterisation of ξ as a function of TAS for the current HALO underwing probe configuration. The ability of cloud particles to adopt changes of air speed between ambient and measurement conditions depends on the cloud particles' inertia as a function of particle size (diameter Dp). The suggested inertia correction factor μ (Dp) for liquid cloud drops ranges between 1 (for Dp < 70 µm) and 0.8 (for 100 µm < Dp < 225 µm) but it needs to be applied carefully with respect to the particles' phase and nature. The correction of measured concentration by both factors, ξ and μ (Dp), yields higher ambient particle concentration by about 10–25 % compared to conventional procedures – an improvement which can be considered as significant for many research applications. The calculated ξ values are specifically related to the considered HALO underwing probe arrangement and may differ for other aircraft. Moreover, suggested corrections may not cover all impacts originating from high flight velocities and from interferences between the instruments and e.g. the aircraft wings and/or fuselage. Consequently, it is important that PAS (as a function of TAS) is individually measured by each probe deployed underneath the wings of a fast-flying aircraft.

1 July 2009 in Journal of Atmospheric and Oceanic Technology
Verified
Journal Article
Open access
PDF file
Merhala ThuraiMerhala Thurai
Merhala Thurai
VBV. N. Bringi
V. N. Bringi
MSMiklós Szakáll
Miklós Szakáll
SMS. K. Mitra
S. K. Mitra
KBK. V. Beard
K. V. Beard
SBS. Borrmann
S. Borrmann
Comparisons of drop shapes between measurements made using 2D video disdrometer (2DVD) and wind-tunnel experiments are presented. Comparisons are made in terms of the mean drop shapes and the axis ratio distributions. Very close agreement of the mean shapes is seen between the two sets of measurements; the same applies to the mean axis ratio versus drop diameter. Also, in both sets of measurements, an increase in the oscillation amplitudes with increasing drop diameter is observed. In the case of the 2DVD, a small increase in the skewness was also detected. Given that the two sets of measurements were conducted in very different conditions, the agreement between the two sets of data implies a certain “robustness” in the mean shape of oscillating drops that may be extended to natural raindrop oscillations, at least in steady rainfall and above the surface layer.