Duncan Craig

Prof. Dr. Duncan Craig

School of Pharmacy, University College London (UCL), 29–39 Brunswick Square, London WC1N 1AX, UK
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Open access
SMStefania Marano
Stefania Marano
SBSusan Anne Barker
Susan Anne Barker
BRBahijja Raimi-Abraham
Bahijja Raimi-Abraham
SMShahrzad Missaghi
Shahrzad Missaghi
ARAli Rajabi-Siahboomi
Ali Rajabi-Siahboomi
Duncan CraigDuncan Craig
Duncan Craig
Solid dispersion technology represents a successful approach to addressing the bioavailability issues caused by the low aqueous solubility of many Biopharmaceutics Classification System (BCS) Class II drugs. In this study, the use of high-yield manufacture of fiber-based dispersion is explored as an alternative approach to monolith production methods. A temperature-controlled solvent-free centrifugal spinning process was used to produce sucrose-based microfibers containing the poorly water-soluble drugs olanzapine and piroxicam (both BCS Class II); these were successfully incorporated into the microfibers and the basic characteristics of fiber diameter, glassy behavior, drug loading capacity and drug-sucrose interaction assessment were measured. Scanning electron microscopy revealed that bead-free drug-loaded microfibers with homogenous morphology and diameter in the range of a few micrometers were prepared using our process. Differential scanning calorimetric and X-ray diffraction analyses showed that both drug and carrier were present in the amorphous state in the microfibers, although in the case of piroxicam-loaded microfibers, the presence of small amounts of crystalline drug was observed under polarized light microscopy and in Fourier transform infrared spectra. Drug dissolution performance was evaluated under both sink and non-sink conditions and was found to be significantly enhanced compared to the corresponding crystalline physical mixtures and pure drugs, with evidence of supersaturation behavior noted under non-sink conditions. This study has demonstrated that microfiber-based dispersions may be manufactured by the centrifugal spinning process and may possess characteristics that are favorable for the enhanced dissolution and oral absorption of drugs.

29 March 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
Francis BrakoFrancis Brako
Francis Brako
RTRichard Thorogate
Richard Thorogate
SMSuntharavathanan Mahalingam
Suntharavathanan Mahalingam
BRBahijja Raimi-Abraham
Bahijja Raimi-Abraham
Duncan CraigDuncan Craig
Duncan Craig
Mohan EdirisingheMohan Edirisinghe
Mohan Edirisinghe
Mucoadhesive delivery systems have attracted remarkable interest recently, especially for their potential to prolong dosage form resident times at sites of application such as the vagina or nasal cavity, thereby improving convenience and compliance as a result of less frequent dosage. Mucoadhesive capabilities need to be routinely quantified during the development of these systems. This is however logistically challenging due to difficulties in obtaining and preparing viable mucosa tissues for experiments. Utilizing artificial membranes as a suitable alternative for quicker and easier analyses of mucoadhesion of these systems is currently being explored. In this study, the mucoadhesive interactions between progesterone-loaded fibers (with varying carboxymethyl cellulose (CMC) content) and either artificial (cellulose acetate) or mucosa membranes are investigated by texture analysis and results across models are compared. Mucoadhesion to artificial membrane was about 10 times that of mucosa, though statistically significant (p = 0.027) association between the 2 data sets was observed. Furthermore, a hypothesis relating fiber–mucosa interfacial roughness (and unfilled void spaces on mucosa) to mucoadhesion, deduced from some classical mucoadhesion theories, was tested to determine its validity. Points of interaction between the fiber and mucosa membrane were examined using atomic force microscopy (AFM) to determine the depths of interpenetration and unfilled voids/roughness, features crucial to mucoadhesion according to the diffusion and mechanical theories of mucoadhesion. A Kendall’s tau and Goodman–Kruskal’s gamma tests established a monotonic relationship between detaching forces and roughness, significant with p-values of 0.014 and 0.027, respectively. A similar relationship between CMC concentration and interfacial roughness was also confirmed. We conclude that AFM analysis of surface geometry following mucoadhesion can be explored for quantifying mucoadhesion as data from interfacial images correlates significantly with corresponding detaching forces, a well-established function of mucoadhesion.

1 April 2014 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
PDF file
MPMaria Fátima Pina
Maria Fátima Pina
MZMin Zhao
Min Zhao
JPJoão F. Pinto
João F. Pinto
JSJoão J. Sousa
João J. Sousa
Duncan CraigDuncan Craig
Duncan Craig
The oral bioavailability enhancement of poorly soluble active pharmaceutical ingredients (APIs) continues to represent a significant issue in drug development. One strategy to overcome this obstacle is the development of amorphous solid dispersion formulations using hydrophilic polymers. The term “solid dispersion” was described by Chiou and Riegelman1 x 1. Chiou, W.L. and Riegelman, S. Pharmaceutical applications of solid dispersion systems. J Pharm Sci. 1971; 60: 1281–1302 Abstract | Full Text PDF | PubMed | Scopus (1347) | Google Scholar See all References as “the dispersion of one or more active ingredients in an inert carrier matrix at solid state prepared by melting (fusion), solvent, or melting–solvent method.” This definition is still applicable despite the field having developed considerably to include a wider range of manufacturing techniques [e.g., hot-melt extrusion (HME)] and new concepts in structural characteristics, particularly involving the recognition of complexities of molecular dispersion of drugs in polymers.

1 May 2020 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
ETEssam A. Tawfik
Essam A. Tawfik
Duncan CraigDuncan Craig
Duncan Craig
SBSusan A. Barker
Susan A. Barker

1 February 2019 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
LBLorina Bisharat
Lorina Bisharat
SBSusan Anne Barker
Susan Anne Barker
ANArjan Narbad
Arjan Narbad
Duncan CraigDuncan Craig
Duncan Craig

3 May 2024 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
RFRawan Fitaihi
Rawan Fitaihi
SAShorooq Abukhamees
Shorooq Abukhamees
SCSe Hun Chung
Se Hun Chung
Duncan CraigDuncan Craig
Duncan Craig
Microneedles (MN) have emerged as an innovative technology for drug delivery, offering a minimally invasive approach to administer therapeutic agents. Recent applications have included ocular drug delivery, requiring the manufacture of sub-millimeter needle arrays in a reproducible and reliable manner. The development of 3D printing technologies has facilitated the fabrication of MN via mold production, although there is a paucity of information available regarding how the printing parameters may influence crucial issues such as sharpness and penetration efficacy. In this study, we have developed and optimized a 3D-printed MN micro-mold using stereolithography (SLA) 3D printing to prepare a dissolving ocular MN system. The effects of a range of parameters including aspect ratio, layer thickness, length, mold shape and printing orientation have been examined with regard to both architecture and printing accuracy of the MN micro-mold, while the effects of printing angle on needle fidelity was also examined for a range of basic shapes (conical, pyramidal and triangular pyramidal). Mechanical strength and in vitro penetration of the polymeric (PVP/PVA) microneedles produced from reverse molds fabricated using MN with a range of shapes and height, and aspect ratios was assessed, followed by ex vivo studies of penetration into excised scleral and corneal tissue. The optimization process identified the parameters required to produce MN with the sharpest tips and highest dimensional fidelity, while the ex vivo studies indicated that these optimized systems would penetrate the ocular tissue with minimal applied pressure, thereby allowing ease of patient self-administration.