Chris Underwood

Prof. Chris Underwood

Department of Mechanical and Construction Engineering, Northumbria University, Newcastle upon Tyne NE1 8ST, UK

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2001 in Solar Energy
Verified
Journal Article
Closed access
AJA.D. Jones
A.D. Jones
CUChris Underwood
Chris Underwood

1 December 2002 in Building and Environment
Verified
Journal Article
Closed access
MGM.M. Gouda
M.M. Gouda
SDS. Danaher
S. Danaher
CUChris Underwood
Chris Underwood

1 July 2011 in Applied Thermal Engineering
Verified
Journal Article
Closed access
MAMathew Aneke
Mathew Aneke
BABrian Agnew
Brian Agnew
CUChris Underwood
Chris Underwood

1 August 2014 in Energy and Buildings
Verified
Journal Article
Closed access
CUChris Underwood
Chris Underwood

1 October 2014 in Applied Thermal Engineering
Verified
Journal Article
Open access
DIDraco Iyi
Draco Iyi
RHReaz Hasan
Reaz Hasan
RPRoger Penlington
Roger Penlington
CUChris Underwood
Chris Underwood
The demand to reduce building cooling load and annual energy consumption can be optimised with the use of Double Skin Facade (DSF). Computational Fluid Dynamics (CFD) methods are frequently used for the analysis of heat transfer through DSF. However, considerable uncertainty exists regarding few key parameters, such as modelling strategies and the solar heat transmitted to the indoor space as a function of the blind tilt angles and positioning within the façade channel. In this paper we have investigated four modelling strategies and the influence of blind tilt angle and their proximity to the façade walls. The DSF system used in this investigation is equipped with venetian blinds and facades that absorb and reflect the incident solar radiation and transfer the direct solar heat gain into the building. A finite volume discretization method with the SIMPLE solution algorithm of the velocity-pressure coupling involving the low-turbulence k–ε model is used. A ray-traced solar model is coupled with long wave radiation model to solve the complete solar and radiation fields along with convection and conduction fields. On the modelling strategies, three dimensional domains were cast over three computational zones; external zone with solar radiation entering the outer skin of glass; buoyancy-driven air cavity zone with convection and transmitted solar radiation; and an internal zone. Also investigated is the thermal behaviour of the DSF due to the blind tilt angles (30°, 45°, 60°, and 75°) and its position from the facade walls (104 mm, 195 mm, 287 mm and 379 mm). Validations of the results are based on experimental data from the literature and the predicted trends compared very well with the experimental measurements. The heat gain due to direct solar radiation and convection through the facades to the internal space are presented. Comparative analysis of the four modelling strategies shows little variation of the results. The implication is a reduction in complexity and cost of modelling, since the additional effort requires in the CFD modelling is not justified by a significant improvement of the results. The variations of the blinds tilt angles as well as its proximity to façade walls significantly influences the convective flow within the façade cavity and the heat gains to the indoor space

1 November 2001 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
PDF file
MGM M Gouda
M M Gouda
SDS Danaher
S Danaher
CUChris Underwood
Chris Underwood
Most heating, ventilation and air conditioning (HVAC) control systems are considered as temperature control problems. In this work, the predicted mean vote (PMV) is used to control the indoor temperature of a space by setting it at a point where the PMV index becomes zero and the predicted percentage of persons dissatisfied (PPD) achieves a maximum threshold of 5%. This is achieved through the use of a fuzzy logic controller that takes into account a range of human comfort criteria in the formulation of the control action that should be applied to the heating system to bring the space to comfort conditions. The resulting controller is free of the set up and tuning problems that hinder conventional HVAC controllers. Simulation results show that the proposed control strategy makes it possible to maximize the indoor thermal comfort and, correspondingly, a reduction in energy use of 20% was obtained for a typical 7-day winter period when compared with conventional control.