Applications of solar energy in dehydration process due to higher prices and shortages of fossil fuels, and to reduce the fuel consumption used in the dehydration processes. In addition, solar energy sources as they are freely available. So, the aim of this study was to develop and evaluate an indirect solar dryer to optimize the efficiency of solar air dryers. A solar dryer consists of a solar flat plate air collector with V corrugated-absorption plates, an insulated drying chamber, and a chimney for exhaust air. The total area of the collector’s is 1.5 m2. The size of the drying cabinet is (80 cm length, 80 cm width, and 80 cm height). The qualitative analysis for drying onions showed that the moisture content of onions was reduced from an initial value of 85% (w.b.) to the final moisture content 5.66% to 6.54% (w.b). The dryer’s efficiency per day was 39.3% and 42.3% at dryer (A) and dryer (B), respectively. Therefore, the use of the developed dryer led to an increase in the dryer’s efficiency by 7.63% for the air flow rate of 2.8 m3/min. While it was 34.1% and 38.82% at dryer (A) and dryer (B), respectively, the use of the developed dryer led to an increase in the dryer’s efficiency by 13.84% for the air flow rate of 1.8 m3/min.
1 July 2019 in Misr Journal of Agricultural Engineering
Three mathematical models were used to determine the coefficient of performance COP of the diffusion absorption refrigeration system DAR. These models give different results of COP because it depends upon various scientific bases. Therefore, in this study used the three models to compare between the values of COP. The first model from viewpoint of temperature thermodynamic ideal cycle, the second model using mass flow rate thermodynamic and the last model employing the cooling capacity of refrigerator. The highest value of COP by (model 1) was 1.26 while the lowest value was 0.77. Model 2 gave 0.671 as highest value and the lowest value was 0.475, respectively. The highest value of COP by (model 3) was 0.155 while the lowest value was 0106. The exponential function behavior showed the relation between the generator temperature (Tg) and the circulation ratio(f) which can be described by the equation f = 629.52e-0.0193Tg, R2 =1.The statistical indicators to select the actual COP indicated to the majority of values for three models by harmonic mean (HM) were 1.118, 0.567 and 0.124, respectively. The study concluded that using second model is the best way to use for judgment of cycle performance because it depend upon the temperatures of refrigeration cycle parts and mass flow rate of working fluids in each part of this cycle.