Alexandre Baudet

Dr. Alexandre Baudet

Faculty of Dentistry, University of Lorraine, 54505 Vandœuvre-lès-Nancy, France
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2022 in Toxics
Verified
Journal Article
Open access
PDF file
Alexandre BaudetAlexandre Baudet
Alexandre Baudet
EBEstelle Baurès
Estelle Baurès
OBOlivier Blanchard
Olivier Blanchard
PCPIERRE LE CANN
PIERRE LE CANN
Jean-pierre GangneuxJean-pierre Gangneux
Jean-pierre Gangneux
AFArnaud Florentin
Arnaud Florentin
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations. The aim of this study was to measure the concentrations of dioxide carbon (CO2), fine particulate matter (PM2.5) and total volatile organic compounds (TVOCs) in situ in private healthcare and elderly care facilities. These pollutants were continuously measured in two rooms of six private healthcare facilities (general practitioner’s offices, dental offices and pharmacies) and four elderly care facilities (nursing homes) in two French urban areas during two seasons: summer and winter. The mean CO2 concentrations ranged from 764 ± 443 ppm in dental offices to 624 ± 198 ppm in elderly care facilities. The mean PM2.5 concentrations ranged from 13.4 ± 14.4 µg/m3 in dental offices to 5.7 ± 4.8 µg/m3 in general practitioner offices. The mean TVOC concentrations ranged from 700 ± 641 ppb in dental offices to 143 ± 239 ppb in general practitioner offices. Dental offices presented higher levels of indoor air pollutants, associated with the dental activities. Increasing the ventilation of these facilities by opening a window is probably an appropriate method for reducing pollutant concentrations and maintaining good indoor air quality.

15 February 2020 in European Journal of Clinical Microbiology & Infectious Diseases
Verified
Journal Article
Closed access
PDF file
Alexandre BaudetAlexandre Baudet
Alexandre Baudet
CKC Kichenbrand
C Kichenbrand
CPC Pulcini
C Pulcini
VDV Descroix
V Descroix
PLP Lesclous
P Lesclous
JGJulie GUILLET
Julie GUILLET

13 October 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Alexandre BaudetAlexandre Baudet
Alexandre Baudet
EBEstelle Baurès
Estelle Baurès
HGHélène Guegan
Hélène Guegan
OBOlivier Blanchard
Olivier Blanchard
MGMonique Guillaso
Monique Guillaso
AFArnaud Florentin
Arnaud Florentin
The indoor air quality of healthcare and care facilities is poorly studied. The aim of this study was to qualitatively and quantitatively describe the chemical pollution and the microbiological contaminations of the indoor environment of these facilities. Methods: A wide range of chemical compounds (39 volatile and 13 semi-volatile organic compounds, carbon dioxide, fine particulate matter) and microorganisms (fungi and bacteria) were studied. Sampling campaigns were conducted in two French cities in summer 2018 and winter 2019 in six private healthcare facilities (general practitioner’s offices, dental offices, pharmacies) and four care facilities (nursing homes). Results: The highest median concentrations of chemical compounds (μg/m3) were measured for alcohols (ethanol: 378.9 and isopropanol: 23.6), ketones (acetone: 18.8), aldehydes (formaldehyde: 11.4 and acetaldehyde: 6.5) and terpenes (limonene: 4.3). The median concentration of PM2.5 was 9.0 µg/m3. The main bacteria of these indoor environments were Staphylococcus, Micrococcus and Bacillus genera, with median bacterial concentrations in the indoor air of 14 cfu/m3. The two major fungal genera were Cladosporium and Penicillium, with median fungal concentrations of 7 cfu/m3. Conclusions: Indoor air in healthcare and care facilities contains a complex mixture of many pollutants found in higher concentrations compared to the indoor air in French hospitals in a previous study.

Alexandre BaudetAlexandre Baudet
Alexandre Baudet
JLJulie Lizon
Julie Lizon
JMJean-Marc Martrette
Jean-Marc Martrette
Frédéric CamelotFrédéric Camelot
Frédéric Camelot
AFArnaud Florentin
Arnaud Florentin
CCCeline Clement
Celine Clement
Biofilms in dental unit waterlines (DUWL) are a potentially significant source of contamination posing a significant health risk as these may come into contact with patients and dental staff during treatment. The aim of this study was to evaluate the microbiological quality of DUWL water treated by Biofilm-Removing-System® (BRS®) and Alpron®/Bilpron® disinfectant solutions for six years in a French university hospital. The microbiological quality of water supplied by 68 dental units—initially shock treated with BRS®, then continuously treated by Alpron® with sterile water during working days and Bilpron® during inactivity period, and combined with purging every morning and after each patient—was assessed biannually during six years for total culturable aerobic bacteria at 22 °C and 36 °C, Legionella sp., Pseudomonas aeruginosa, and total coliforms. A total of 628 samples were analyzed, 99.8% were compliant with extended microbiological levels, and we never detected pathogen bacteria like Legionella sp. and P. aeruginosa. Only one sample (0.2%) was noncompliant with the level of total culturable aerobic bacteria at 36 °C, which exceeded 140 colony forming units per mL. The protocol implemented in our university hospital gives excellent results and enables control of the microbiological quality of DUWL water in the long term.

16 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Stéphane DerruauStéphane Derruau
Stéphane Derruau
JBJérôme Bouchet
Jérôme Bouchet
ANAli Nassif
Ali Nassif
Alexandre BaudetAlexandre Baudet
Alexandre Baudet
Kazutoyo YasukawaKazutoyo Yasukawa
Kazutoyo Yasukawa
O(on behalf of TASK FORCE COVID-19–Collège National des EnseignantS en Biologie Orale (CNESBO)—France
on behalf of TASK FORCE COVID-19–Collège National des EnseignantS en Biologie Orale (CNESBO)—France
The outbreak of Coronavirus Disease 2019 (COVID-19), caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), has significantly affected the dental care sector. Dental professionals are at high risk of being infected, and therefore transmitting SARS-CoV-2, due to the nature of their profession, with close proximity to the patient’s oropharyngeal and nasal regions and the use of aerosol-generating procedures. The aim of this article is to provide an update on different issues regarding SARS-CoV-2 and COVID-19 that may be relevant for dentists. Members of the French National College of Oral Biology Lecturers (“Collège National des EnseignantS en Biologie Orale”; CNESBO-COVID19 Task Force) answered seventy-two questions related to various topics, including epidemiology, virology, immunology, diagnosis and testing, SARS-CoV-2 transmission and oral cavity, COVID-19 clinical presentation, current treatment options, vaccine strategies, as well as infection prevention and control in dental practice. The questions were selected based on their relevance for dental practitioners. Authors independently extracted and gathered scientific data related to COVID-19, SARS-CoV-2 and the specific topics using scientific databases. With this review, the dental practitioners will have a general overview of the COVID-19 pandemic and its impact on their practice.

Alexandre BaudetAlexandre Baudet
Alexandre Baudet
JLJulie Lizon
Julie Lizon
JMJean-Marc Martrette
Jean-Marc Martrette
Frédéric CamelotFrédéric Camelot
Frédéric Camelot
AFArnaud Florentin
Arnaud Florentin
CCCeline Clement
Celine Clement
Water is essential during dental care. Physical and chemical techniques should be used to maintain a good water quality with respect to bacteria, and to ensure the safety of exposed patients and dental staff. The aim of this survey was to assess the modalities used by dental practitioners in Eastern France to maintain the water quality of their dental unit waterlines (DUWLs). A questionnaire about water quality maintenance practices was sent to 870 dental offices in 2016. The questionnaires were completed by 153 dental offices, covering about 223 dental care units. The majority of units were fed by mains water (91.0%), which is generally unfiltered (71.3%). One-third (33.6%) of the units had an independent water bottle reservoir. Flushing, a basic physical technique to improve the quality of units’ outflow water, was practiced in 65.4% of dental offices. Concerning the chemical treatment of water, it was used for 62.1% of the units. An analysis of the microbiological quality of the DUWL water was only carried out in 2.6% of the offices. In conclusion, providing better training to dental staff seems necessary to improve their practices and to generalize procedures that improve the microbiological quality of the water used.