Hyuck Min Kwon

Dr. Hyuck Min Kwon

Yonsei University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KPKwan Kyu Park
Kwan Kyu Park
CHChang Dong Han
Chang Dong Han
IYIck-Hwan Yang
Ick-Hwan Yang
WLWoo-Suk Lee
Woo-Suk Lee
JHJoo Hyung Han
Joo Hyung Han
HKHyuck Min Kwon
Hyuck Min Kwon
The aim of this study was to compare the clinical and radiologic outcomes of robot-assisted unicompartmental knee arthroplasty (UKA) to those of conventional UKA in Asian patients. Fifty-five patients underwent robot-assisted UKA and 57 patients underwent conventional UKA were assessed in this study. Preoperative and postoperative range of motion (ROM), American Knee Society (AKS) score, Western Ontario McMaster University Osteoarthritis Index scale score (WOMAC), and patellofemoral (PF) score values were compared between the two groups. The mechanical femorotibial angle (mFTA) and Kennedy zone were also measured. Coronal alignments of the femoral and tibial components and posterior slopes of the tibial component were compared. Additionally, polyethylene (PE) liner thicknesses were compared. There was no significant difference between the two groups regarding postoperative ROM, AKS, WOMAC and PF score. Robot group showed fewer radiologic outliers in terms of mFTA and coronal alignment of tibial and femoral components (p = 0.022, 0.037, 0.003). The two groups showed significantly different PE liner thicknesses (8.4 ± 0.8 versus 8.8 ± 0.9, p = 0.035). Robot group was the only influencing factor for reducing radiologic outlier (postoperative mFTA) in multivariate model (odds ratio: 2.833, p = 0.037). In this study, robot-assisted UKA had many advantages over conventional UKA, such as its ability to achieve precise implant insertion and reduce radiologic outliers. Although the clinical outcomes of robot-assisted UKA over a short-term follow-up period were not significantly different compared to those of conventional UKA, longer follow-up period is needed to determine whether the improved radiologic accuracy of the components in robotic-assisted UKA will lead to better clinical outcomes and improved long-term survival.

12 February 2024 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
WLWoo-Suk Lee
Woo-Suk Lee
KPKwan Kyu Park
Kwan Kyu Park
BCByung-Woo Cho
Byung-Woo Cho
JPJun Young Park
Jun Young Park
IKInuk Kim
Inuk Kim
HKHyuck Min Kwon
Hyuck Min Kwon
Background: The cause of early septic failure after two-stage exchange revision total knee arthroplasty (TKA) for chronic periprosthetic joint infection (PJI) and the factors affecting it are not well known. The purpose of this study was to determine the surgical outcomes and the risk factors for early septic failure after two-stage revision TKA for chronic PJI. Methods: We identified a total of 246 adult patients who met the Musculoskeletal Infection Society (MSIS) diagnostic criteria for chronic PJI at two academic tertiary hospitals from March 2012 to December 2018. Finally, 151 patients who consecutively received two-stage exchange revision TKA for chronic PJI and who had a minimum 3-year follow-up were enrolled and retrospectively reviewed. Successful surgical treatment was evaluated for two-stage revision TKA and risk factors for early septic failure were identified. Results: Early septic failures occurred within 3 years after reimplantation in 48 patients (31.8%). After accounting for potentially confounding variables, we found that male patient [odds ratio (OR): 2.753, 95% confidence interval (CI) 1.099–6.893, p = 0.031], fungus or mycobacterial infection (OR: 5.224, 95% CI 1.481–18.433, p = 0.01), and positive culture at reimplantation (OR: 4.407, 95% CI 1.255–15.480, p = 0.021) were independently associated with early septic failure after two-stage exchange revision TKA. Conclusion: Male patients, fungus or mycobacterial infection, and positive culture at reimplantation were independently associated with an increased risk of early septic failure after two-stage exchange revision TKA despite normal C-reactive protein values prior to reimplantation. Further prospective and high-quality studies are needed to determine the risk factors of two-stage exchange revision TKA for chronic PJI. Level of evidence: level IV; retrospective comparison; treatment study.

25 July 2019 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
HKHyuck Min Kwon
Hyuck Min Kwon
KKKyoung-Tak Kang
Kyoung-Tak Kang
JKJung Hwan Kim
Jung Hwan Kim
KPKwan Kyu Park
Kwan Kyu Park

1 May 2020 in Experimental Gerontology
Verified
Journal Article
Closed access
HKHyuck Min Kwon
Hyuck Min Kwon
IYIck-Hwan Yang
Ick-Hwan Yang
KPKwan Kyu Park
Kwan Kyu Park
BCByung Woo Cho
Byung Woo Cho
JBJunwoo Byun
Junwoo Byun
WLWoo-Suk Lee
Woo-Suk Lee

4 April 2018 in The Journal of Knee Surgery
Verified
Journal Article
Closed access
PDF file
HKHyuck Min Kwon
Hyuck Min Kwon
IYIck-Hwan Yang
Ick-Hwan Yang
WLWoo-Suk Lee
Woo-Suk Lee
AYAlvin Ray L. Yu
Alvin Ray L. Yu
SOSang Yun Oh
Sang Yun Oh
KPKwan Kyu Park
Kwan Kyu Park
Accurate measurement of knee range of motion (ROM) is critical to predict the outcomes of knee surgery and prognosis. We investigated the reliability of knee ROM measurements by goniometer compared with robotic system. Fifty-three patients with medial osteoarthritis who were planning to undergo unicompartmental knee arthroplasty (UKA) with robotic UKA were prospectively enrolled. During the operation, knee ROM measurement was performed in both flexion and extension before and after insertion of the implant using both a goniometer and robotic system. The intraclass correlation coefficient (ICC) of extension measured by the goniometer and robotic system showed good agreement; however, the ICC of flexion did not show good agreement. During passive flexion, the mean values measured before insertion of the implant were significantly lower by goniometer (134.6 ± 6.43) than by robot (145.4 ± 6.80; p = 0.017); likewise, the mean values after insertion of the implant were significantly lower by goniometer (138.6 ± 6.07) than by robotic system (147.0 ± 6.60; p = 0.045). A goniometer can underestimate knee ROM measurements compared with robotic system, especially in flexion. Orthopaedic surgeons should be cautious when measuring the flexion angle with a goniometer.

1 January 2021 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
SSSeokyung Shin
Seokyung Shin
YCYong Seon Choi
Yong Seon Choi
HSHye Jung Shin
Hye Jung Shin
IYIck Hwan Yang
Ick Hwan Yang
KPKwan Kyu Park
Kwan Kyu Park
SKSo Yeon Kim
So Yeon Kim
Introduction: We evaluated whether preoperative carbohydrate drink would be able to decrease postoperative nausea and vomiting (PONV) and improve the quality of recovery (QoR) in diabetic patients undergoing total knee arthroplasty (TKA). Methods: Eighty-two patients were randomized to either the intravenous (IV) Dextrose group (n = 41) or Oral carbohydrate (CHO) group (n = 41). The IV Dextrose group received dextrose solution mixed with insulin while fasting, and the Oral CHO group received carbohydrate drinks preoperatively. PONV was assessed up to postoperative 36 hours, and QoR was assessed before surgery and on postoperative day (POD) 1. Blood glucose was measured from the morning of surgery until POD 1. Results: PONV scores were not different between the groups. Postoperative QoR scores were significantly higher in the Oral CHO group (median [interquartile range]; 160 [153 to 167]) than the IV Dextrose group (155 [147 to 159]) (P = 0.009), but the difference did not meet the minimal clinically important difference. Blood glucose was comparable between the groups. Discussion: Preoperative CHO drink did not reduce PONV in diabetic patients after total knee arthroplasty. A statistically significant but clinically questionable improvement in the QoR was seen in the Oral CHO group. However, preoperative CHO drink did not increase hyperglycemia, which suggests that it may be a safe component of perioperative care in diabetic patients.