Antibodies of the secretory IgA (SIgA) class comprise the first line of antigen-specific immune defense, preventing access of commensal and pathogenic microorganisms and their secreted products into the body proper. In addition to preventing infection, SIgA shapes the composition of the gut microbiome. SIgA is transported across intestinal epithelial cells into gut secretions by the polymeric immunoglobulin receptor (pIgR). The epithelial surface is protected by a thick network of mucus, which is composed of a dense, sterile inner layer and a loose outer layer that is colonized by commensal bacteria. Immunofluorescence microscopy of mouse and human colon tissues demonstrated that the SIgA co-localizes with gut bacteria in the outer mucus layer. Using mice genetically deficient for pIgR and/or mucin-2 (Muc2, the major glycoprotein of intestinal mucus), we found that Muc2 but not SIgA was necessary for excluding gut bacteria from the inner mucus layer in the colon. Our findings support a model whereby SIgA is anchored in the outer layer of colonic mucus through combined interactions with mucin proteins and gut bacteria, thus providing immune protection against pathogens while maintaining a mutually beneficial relationship with commensals.
Detection of histidine-rich protein 2 (HRP2) from the malaria parasite Plasmodium falciparum provides evidence for active or recent infection, and is utilized for both diagnostic and surveillance purposes, but current laboratory immunoassays for HRP2 are hindered by low sensitivities and high costs. Here we present a new HRP2 immunoassay based on antigen capture through a bead-based system capable of detecting HRP2 at sub-picogram levels. The assay is highly specific and cost-effective, allowing fast processing and screening of large numbers of samples. We utilized the assay to assess results of HRP2-based rapid diagnostic tests (RDTs) in different P. falciparum transmission settings, generating estimates for true performance in the field. Through this method of external validation, HRP2 RDTs were found to perform well in the high-endemic areas of Mozambique and Angola with 86.4% and 73.9% of persons with HRP2 in their blood testing positive by RDTs, respectively, and false-positive rates of 4.3% and 0.5%. However, in the low-endemic setting of Haiti, only 14.5% of persons found to be HRP2 positive by the bead assay were RDT positive. Additionally, 62.5% of Haitians showing a positive RDT test had no detectable HRP2 by the bead assay, likely indicating that these were false positive tests. In addition to RDT validation, HRP2 biomass was assessed for the populations in these different settings, and may provide an additional metric by which to estimate P. falciparum transmission intensity and measure the impact of interventions.
7 September 2018 in The Journal of Infectious Diseases
Detection of Plasmodium antigens provides evidence of malaria infection status and is the basis for most malaria diagnosis. We developed a sensitive bead-based multiplex assay for laboratory use, which simultaneously detects pan-Plasmodium aldolase (pAldo), pan-Plasmodium lactate dehydrogenase (pLDH), and P. falciparum histidine-rich protein 2 (PfHRP2) antigens. The assay was validated against purified recombinant antigens, monospecies malaria infections, and noninfected blood samples. To test against samples collected in an endemic setting, Angolan outpatient samples (n = 1267) were assayed. Of 466 Angolan samples positive for at least 1 antigen, the most common antigen profiles were PfHRP2+/pAldo+/pLDH+ (167, 36%), PfHRP2+/pAldo−/pLDH− (163, 35%), and PfHRP2+/pAldo+/pLDH− (129, 28%). Antigen profile was predictive of polymerase chain reaction (PCR) positivity and parasite density. Eight Angolan samples (1.7%) had no or very low PfHRP2 but were positive for 1 or both of the other antigens. PCR analysis confirmed 3 (0.6%) were P. ovale infections and 2 (0.4%) represented P. falciparum parasites lacking Pfhrp2 and/or Pfhrp3. These are the first reports of Pfhrp2/3 deletion mutants in Angola. High-throughput multiplex antigen detection can inexpensively screen for low-density P. falciparum, non-falciparum, and Pfhrp2/3-deleted parasites to provide population-level antigen estimates and identify specimens requiring further molecular characterization.
Background: Accurate SARS-CoV-2 serological assays are critical for COVID-19 serosurveillance. However, previous studies have indicated possible cross-reactivity of these assays, including in malaria-endemic areas. Methods: We tested 213 well-characterized pre-pandemic samples from Nigeria using two SARS-CoV-2 serological assays: Abbott Architect IgG and Euroimmun NCP IgG assay, both targeting SARS-CoV-2 nucleocapsid protein. To assess antibody binding strength, an avidity assay was performed on these samples and on plasma from SARS-CoV-2 PCR-positive persons. Results: Thirteen (6.1%) of 212 samples run on the Abbott assay and 38 (17.8%) of 213 run on the Euroimmun assay were positive. Anti-Plasmodium IgG levels were significantly higher among false-positives for both Abbott and Euroimmun; no association was found with active P. falciparum infection. An avidity assay using various concentratIons of urea wash in the Euroimmun assay reduced loosely-bound IgG: of 37 positive/borderline pre-pandemic samples, 46%, 86%, 89%, and 97% became negative using 2M, 4M, 5M, and 8M urea washes, respectively. The wash slightly reduced avidity of antibodies from SARS-CoV-2 patients within 28 days of PCR confirmation; thereafter avidity increased for all urea concentrations except 8M. Conclusions: This validation found moderate to substantial cross-reactivity on two SARS-CoV-2 serological assays using samples from a malaria-endemic setting. A simple urea wash appeared to alleviate issues of cross-reactivity.
Recently, a real-time PCR assay known as photo-induced electron transfer (PET)-PCR which relies on self-quenching primers for the detection of Plasmodium spp. and Plasmodium falciparum was described. PET-PCR assay was found to be robust, and easier to use when compared to currently available real-time PCR methods. The potential of PET-PCR for molecular detection of malaria parasites in a nationwide malaria community survey in Haiti was investigated.
As a nation reduces the burden of falciparum malaria, identifying areas of transmission becomes increasingly difficult. Over the past decade, the field of utilizing malaria serological assays to measure exposure has grown rapidly, and a variety of serological methods for data acquisition and analysis of human IgG against falciparum antigens are available. Here, different immunoassays and statistical methods are utilized to analyse samples from a low transmission setting and directly compare the estimates generated. A subset of samples (n = 580) from a 2012 Haitian nationwide malaria survey was employed as sample population of low falciparum endemicity. In addition to the Haitian samples, samples from 247 US residents were used as a reference population of ‘true seronegatives’. Data acquisition was performed through standard ELISA and bead-based multiplex assays assaying for IgG antibodies to the Plasmodium falciparum antigens MSP-1p19, MSP-1p42(D), MSP-1p42(F), and AMA-1. Appropriate parametric distributions and seropositivity cutoff values were determined by statistical measures. Data from both assays showed a strong positive skew, and the lognormal distribution was found to be an appropriate statistical fit to the Haitian and American populations. The American samples served as a good serological true negative population for the multiplex assay, but not for ELISA-based data. Mixture model approaches to determine seronegative and seropositive populations from the Haitian data showed a high degree of distribution overlap—likely due to the historical low falciparum transmission in this nation. Different fittings to the reversible catalytic model resulted depending upon the immunoassay utilized and seropositivity cutoff method employed. Data were also analysed through fitting to penalized B-splines, presenting another possible analytical tool for the analysis of malaria serological data. Standardization of serological techniques and analyses may prove difficult as some tools can prove to be more useful depending on the area and parasite in question, making clear interpretation a vital pursuit. The presented analysis in the low-endemic nation of Haiti found malaria-naive US residents to be an appropriate seronegative reference population for the multiplex assay, and this assay providing consistent estimates between MSP-1 and AMA-1 antigens of percent seropositives for this low-endemic population.