Carmen Pérez-Gandía

Prof. Carmen Pérez-Gandía

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Diabetes Technology & Therapeutics
Verified
Journal Article
Closed access
CPCarmen Pérez-Gandía
Carmen Pérez-Gandía
AFA. Facchinetti
A. Facchinetti
GSG. Sparacino
G. Sparacino
CCC. Cobelli
C. Cobelli
EAEnrique J. Gómez Aguilera
Enrique J. Gómez Aguilera
MHM.E. Hernando
M.E. Hernando
Background and Aims: Continuous glucose monitoring (CGM) devices could be useful for real-time management of diabetes therapy. In particular, CGM information could be used in real time to predict future glucose levels in order to prevent hypo-/hyperglycemic events. This article proposes a new online method for predicting future glucose concentration levels from CGM data. Methods: The predictor is implemented with an artificial neural network model (NNM). The inputs of the NNM are the values provided by the CGM sensor during the preceding 20 min, while the output is the prediction of glucose concentration at the chosen prediction horizon (PH) time. The method performance is assessed using datasets from two different CGM systems (nine subjects using the Medtronic [Northridge, CA] Guardian® and six subjects using the Abbott [Abbott Park, IL] Navigator®). Three different PHs are used: 15, 30, and 45 min. The NNM accuracy has been estimated by using the root mean square error (RMSE) and prediction delay. Results: The RMSE is around 10, 18, and 27 mg/dL for 15, 30, and 45 min of PH, respectively. The prediction delay is around 4, 9, and 14 min for upward trends and 5, 15, and 26 min for downward trends, respectively. A comparison with a previously published technique, based on an autoregressive model (ARM), has been performed. The comparison shows that the proposed NNM is more accurate than the ARM, with no significant deterioration in the prediction delay. Conclusions: The proposed NNM is a reliable solution for the online prediction of future glucose concentrations from CGM data.

3 August 2020 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
JCJaime Carrillo-Moreno
Jaime Carrillo-Moreno
CPCarmen Pérez-Gandía
Carmen Pérez-Gandía
RSRafael Sendra-Arranz
Rafael Sendra-Arranz
GGGarcía-Sáez Gema
García-Sáez Gema
MHM. Elena Hernando
M. Elena Hernando
Alvaro GutiérrezAlvaro Gutiérrez
Alvaro Gutiérrez