Edward Sazonov

Dr. Edward Sazonov

Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35487, USA
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2010 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Edward SazonovEdward Sazonov
Edward Sazonov
GFGeorge Fulk
George Fulk
JHJames Hill
James Hill
YSYves Schutz
Yves Schutz
RBRaymond Browning
Raymond Browning
Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) with out significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.

25 September 2009 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Edward SazonovEdward Sazonov
Edward Sazonov
HLHaodong Li
Haodong Li
DCDarrell Curry
Darrell Curry
PPPragasen Pillay
Pragasen Pillay
The task of structural health monitoring (SHM) of aging highway bridges and overpasses is important not only from the point of preventing economic losses from traffic delays and detours but also is a matter of preventing catastrophic failures and loss of human life. In recent years, wireless sensor technologies have been used extensively to develop SHM platforms for bridges. A limitation of wireless sensors is the finite life span of batteries and high cost of battery replacements, which make such systems prohibitively expensive in many cases. Energy harvesting is a solution capable to alleviate this problem. A novel wireless sensor system is presented that harvests vibrations of the bridge created by passing traffic, which is converted into usable electrical energy by means of a linear electromagnetic generator. Utilization of an electromagnetic generator allows harvesting of up to 12.5 mW of power in the resonant mode with the frequency of excitation at 3.1 Hz, in this particular design. The novelty of the system also includes tight integration of the power generator and a smart algorithm for energy conversion that switches between the low-power mode and the impedance matching mode. Finally, results of field experiments are presented in which the wireless system is operated exclusively by the harvested energy of vibration on a rural highway bridge with low traffic volume.

17 February 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JFJuan Fontana
Juan Fontana
MFMuhammad Farooq
Muhammad Farooq
Edward SazonovEdward Sazonov
Edward Sazonov
Objective monitoring of food intake and ingestive behavior in a free-living environment remains an open problem that has significant implications in study and treatment of obesity and eating disorders. In this paper, a novel wearable sensor system (automatic ingestion monitor, AIM) is presented for objective monitoring of ingestive behavior in free living. The proposed device integrates three sensor modalities that wirelessly interface to a smartphone: a jaw motion sensor, a hand gesture sensor, and an accelerometer. A novel sensor fusion and pattern recognition method was developed for subject-independent food intake recognition. The device and the methodology were validated with data collected from 12 subjects wearing AIM during the course of 24 h in which both the daily activities and the food intake of the subjects were not restricted in any way. Results showed that the system was able to detect food intake with an average accuracy of 89.8%, which suggests that AIM can potentially be used as an instrument to monitor ingestive behavior in free-living individuals.

22 April 2008 in Physiological Measurement
Verified
Journal Article
Closed access
Edward SazonovEdward Sazonov
Edward Sazonov
SSStephanie Schuckers
Stephanie Schuckers
PLPaulo Lopez-Meyer
Paulo Lopez-Meyer
OMOleksandr Makeyev
Oleksandr Makeyev
NSNadezhda Sazonova
Nadezhda Sazonova
MNMichael Neuman
Michael Neuman
A methodology of studying of ingestive behavior by non-invasive monitoring of swallowing (deglutition) and chewing (mastication) has been developed. The target application for the developed methodology is to study the behavioral patterns of food consumption and producing volumetric and weight estimates of energy intake. Monitoring is non-invasive based on detecting swallowing by a sound sensor located over laryngopharynx or by a bone-conduction microphone and detecting chewing through a below-the-ear strain sensor. Proposed sensors may be implemented in a wearable monitoring device, thus enabling monitoring of ingestive behavior in free-living individuals. In this paper, the goals in the development of this methodology are two-fold. First, a system comprising sensors, related hardware and software for multi-modal data capture is designed for data collection in a controlled environment. Second, a protocol is developed for manual scoring of chewing and swallowing for use as a gold standard. The multi-modal data capture was tested by measuring chewing and swallowing in 21 volunteers during periods of food intake and quiet sitting (no food intake). Video footage and sensor signals were manually scored by trained raters. Inter-rater reliability study for three raters conducted on the sample set of five subjects resulted in high average intra-class correlation coefficients of 0.996 for bites, 0.988 for chews and 0.98 for swallows. The collected sensor signals and the resulting manual scores will be used in future research as a gold standard for further assessment of sensor design, development of automatic pattern recognition routines and study of the relationship between swallowing/chewing and ingestive behavior.

1 August 2005 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
Edward SazonovEdward Sazonov
Edward Sazonov
PKPowsiri Klinkhachorn
Powsiri Klinkhachorn

17 October 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Edward SazonovEdward Sazonov
Edward Sazonov
JFJuan Fontana
Juan Fontana
Objective and automatic sensor systems to monitor ingestive behavior of individuals arise as a potential solution to replace inaccurate method of self-report. This paper presents a simple sensor system and related signal processing and pattern recognition methodologies to detect periods of food intake based on non-invasive monitoring of chewing. A piezoelectric strain gauge sensor was used to capture movement of the lower jaw from 20 volunteers during periods of quiet sitting, talking and food consumption. These signals were segmented into non-overlapping epochs of fixed length and processed to extract a set of 250 time and frequency domain features for each epoch. A forward feature selection procedure was implemented to choose the most relevant features, identifying from 4 to 11 features most critical for food intake detection. Support vector machine classifiers were trained to create food intake detection models. Twenty-fold cross-validation demonstrated per-epoch classification accuracy of 80.98% and a fine time resolution of 30 s. The simplicity of the chewing strain sensor may result in a less intrusive and simpler way to detect food intake. The proposed methodology could lead to the development of a wearable sensor system to assess eating behaviors of individuals.