To enhance the outage quality of a distribution system with a high penetration of PV renewable energy, this paper proposes a coordinating control strategy for an on-load tap changer (OLTC) of the main transformer in a distribution substation and PV smart inverters. The voltages at the end-points of all distribution feeders that are served by the main transformer and the power generation of each PV system are collected using a SCADA system. The hourly tap position of the OLTC is then derived from the daily profiles of feeder voltage and the injected power that is generated by all PV systems along the feeder. Thereafter, the PV smart inverters perform autonomous control of reactive power compensation so that the voltage at the point of common coupling (PCC) can be fixed at the specified voltage level. To demonstrate the effectiveness of the proposed voltage control strategy, a main transformer, which serves six feeders of the Taiwan Power Company (Taipower) with high PV penetration, was considered in a case study. The proposed coordinating control of the OLTC and PV smart inverters dramatically improved the voltage quality of the distribution feeder and enabled the effective mitigation of the impact of large PV integration in the distribution system.
1 September 2020 in IEEE Transactions on Industry Applications
This paper presents the innovative control scheme of renewable ancillary services to support the system operation of a bulk power system with high penetration of renewable energy. The smart inverters of PV systems can be controlled to adjust the renewable generation of real and reactive power according to the variation of system voltage and frequency. The dispatch control of renewable ancillary services is integrated with the energy management system (EMS) to achieve the coordination control of renewable energy and synchronous generators. The sensitivity factors of renewable system was applied to determine the generation curtailment for the mitigation of line overloading. The ancillary service of reactive power compensation by renewable energy was considered to improve the system voltage quality. The emergency generation control of renewable systems with fast ramping up capability was applied to illustrate the effectiveness of renewable ancillary service to improve the system frequency response after sudden generator tripping. Based on the computer simulation of an actual power system with large renewable energy to be integrated, the functions of virtual synchronous generators by the photovoltaic (PV) systems and wind farms have to be applied to ensure the successful steady state operation and to improve the system transient stability for severe disturbance contingency.
18 December 2020 in IEEE Transactions on Industry Applications
This article proposes a fault identification method that is embedded in an asset management system (AMS) to identify the faulted location based on the fault flags reported from the fault indicators (FIs). The fault identification model based on the Petri-net technology is developed using the distribution network topology generated by a geographic information system. The proposed method uses the data set of fault flags generated by FIs, the statuses of circuit breakers, the available precurrent and postcurrent measurements of FIs, and the loadings of distribution feeders and laterals. The hybrid communication system is applied to provide two-way communication between the control center and FIs. The AMS with the embedded fault identification method can dispatch the repair crews to the fault location faster to accelerate the customer service restoration. A distribution feeder of Taiwan Power Company was selected for the computer simulation to demonstrate the effectiveness of the proposed method by using the communication-capable FIs to identify the exact fault location of distribution lines after a short circuit fault occurs in a distribution system.
Electrical power is essential in human life. Thus, the security and reliability of its supply are of critical importance in a country’s industrial and economic development. The leakage and improper use of electricity may cause serious problems such as fire and electrocution. To prevent such incidents and minimize the loss of life and property, a leakage current detector and warning system are developed in this study. With a high-precision current transformer and high-gain linear converter, the detector effectively detects leakage current over 1 mA, which is validated in different methods. The detector can be integrated into widely used electric meters (Taipower Datong’s sub-meter model D4S) easily, and information on detected leakage current is transmitted to the cloud server through narrowband IoT wireless communication (NB-IoT) to warn users and management personnel of the electrical power line. The proposed detector and system are expected to prevent the fire caused by leakage current which was the main cause of the fire at homes and buildings and can be an effective means to manage the electrical powerline system and metering facilities.
1 January 2001 in IEE Proceedings - Generation, Transmission and Distribution
To support transformer load management, a narrow-band power line carrier (PLC)-based identifier has been designed and developed for the determination of customers served by each distribution transformer. The transmission characteristics of a PLC signal over low-voltage distribution lines is simulated by using the mathematical model of distribution transformers, line conductors, and customer loading at high frequencies of the carrier signal. After completing the development of PLC-based identifier, a field test has been executed to verify the performance of the identifier to determine the connectivity of the distribution transformer and the customers served without requiring power service interruption. With the customer account numbers updated by the PLC identifier, the monthly energy consumption and the service type of customers served by each distribution transformer are retrieved from the customer information system. The daily power profile and peak loading of the distribution transformers are then derived according to the energy consumption and the typical load patterns of the customers served.