Synchronous colocated collaborative sensemaking requires that analysts share their information and insights with each other. The challenge is to know when is the right time to share what information without disrupting the present state of analysis. This is crucial in ad-hoc sensemaking sessions with mobile devices because small screen space limits information display. To address these tensions, we propose and evaluate RAMPARTS - a spatially aware sensemaking system for collaborative crime analysis that aims to support faster information sharing, clue-finding, and analysis. We compare RAMPARTS to an interactive tabletop and a paper-based method in a controlled laboratory study. We found that RAMPARTS significantly decreased task completion time compared to paper, without affecting cognitive load or task completion time adversely compared to an interactive tabletop. We conclude that designing for ad-hoc colocated sensemaking on mobile devices could benefit from spatial awareness. In particular, spatial awareness could be used to identify relevant information, support diverse alignment styles for visual comparison, and enable alternative rhythms of sensemaking.
Background: The consensus on how to choose a reference gene for serum or plasma miRNA expression qPCR studies has not been reached and none of the potential candidates have yet been convincingly validated. We proposed a new in silico approach of finding a suitable reference for human, circulating miRNAs and identified a new set of endogenous reference miRNA based on miRNA profiling experiments from Gene Expression Omnibus. We used 3 known normalization algorithms (NormFinder, BestKeeper, GeNorm) to calculate a new normalization score. We searched for a universal set of endogenous miRNAs and validated our findings on 2 new datasets using our approach.Results: We discovered and validated a set of 13 miRNAs (miR-222, miR-92a, miR-27a, miR-17, miR-24, miR-320a, miR-25, miR-126, miR-19b, miR-199a-3p, miR-30b, miR-30c, miR-374a) that can be used to create a reliable reference combination of 3 miRNAs. We showed that on average the mean of 3 miRNAs (p = 0.0002) and 2 miRNAs (p = 0.0031) were a better reference than single miRNA. The arithmetic means of 3 miRNAs: miR-24, miR-222 and miR-27a was shown to be the most stable combination of 3 miRNAs in validation sets.Conclusions: No single miRNA was suitable as a universal reference in serum miRNA qPCR profiling, but it was possible to designate a set of miRNAs, which consistently contributed to most stable combinations.
The increasing availability of drones produces a number of opportunities for integrating them in everyday settings and using drones to create engaging experiences for users. In this paper, we investigate how drones can support amateur runners in their endeavours. We explore the possible roles for drones during amateur running races. Through two field studies and multiple semi-structured interviews, we gain new insights on how drones could augment the experience of both runners and supporters during organised races. Finally, we contribute a set of future directions for integrating drones into the sports experience.
This paper presents a novel approach to a complex process of electrical capacitance tomography (ECT) measurement data analysis. ECT is frequently employed for non-invasive monitoring of industrial process phenomena. Proposed methodology is based on the premeditated integration of the spatial and temporal relations inherent in the measurement records into the workflow of the analysis procedure. We propose a concept of interactive timeline that enables arranging data visualization according to the user’s current focus along the process of analysis. We evaluated the proposed method using a prototype system in a task-based user study conducted with a group of domain experts. The evaluation is based on gravitational silo flow measurement datasets. Proposed prototype system enables diverse data manipulation in a more natural way allowing the user to switch back and forth between space and time domains along the data analysis trail. Experiments with the prototype system showed that the accuracy and completion times have significantly improved in comparison to the performance measured in the baseline condition. Additionally, the participants reported decreased physical load with improved efficiency measured with NASA task load index. Finally, a short discussion coupled with directions for the future of interactive spatio-temporal ECT measurement data analysis conclude the paper.
4 December 2018 in Diabetes Technology & Therapeutics
Background: Continuous glucose monitoring (CGM) is a method of estimating blood glucose values from those recorded in the interstitial fluid. Because increasingly longer CGM measurements are possible, errors and data loss become more and more likely and potentially more damaging to accurate calculations of glycemic variability (GV) indices. Our research investigates the resistance of the CGM recording to data loss. Methods: We collected 71 CGM recordings (duration of min: 2, max: 265, median: 42 days) from patients with type 1 diabetes and used three algorithms to introduce missing data. We calculated mean and standard deviation (SD) of absolute percentage error of 12 variability indices and correlated those with the percentage of missing data and duration of the measurements. Results: Mean absolute percentage error of variability indices increased linearly with the percentage of missing data along with SD of absolute percentage error. Except for mean amplitude of glycemic excursions and time spent in hypoglycemia, all absolute errors never exceeded 25%, while mean absolute errors stayed below 5%. The gradient removal algorithm introduced errors larger than the single datapoint and block removal algorithms. The absolute percentage error of variability indices correlated negatively with the duration of the CGM measurements. Conclusions: Standard GV measurements in long-term glucose monitoring are robustly resistant to data loss.
The presented paper proposes a hybrid neural architecture that enables intelligent data analysis efficacy to be boosted in smart sensor devices, which are typically resource-constrained and application-specific. The postulated concept integrates prior knowledge with learning from examples, thus allowing sensor devices to be used for the successful execution of machine learning even when the volume of training data is highly limited, using compact underlying hardware. The proposed architecture comprises two interacting functional modules arranged in a homogeneous, multiple-layer architecture. The first module, referred to as the knowledge sub-network, implements knowledge in the Conjunctive Normal Form through a three-layer structure composed of novel types of learnable units, called L-neurons. In contrast, the second module is a fully-connected conventional three-layer, feed-forward neural network, and it is referred to as a conventional neural sub-network. We show that the proposed hybrid structure successfully combines knowledge and learning, providing high recognition performance even for very limited training datasets, while also benefiting from an abundance of data, as it occurs for purely neural structures. In addition, since the proposed L-neurons can learn (through classical backpropagation), we show that the architecture is also capable of repairing its knowledge.