Park Ye Jin

Ms. Park Ye Jin


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
ELEunji Lee
Eunji Lee
HKHye Jin Kim
Hye Jin Kim
PJPark Ye Jin
Park Ye Jin
SLSeungjun Lee
Seungjun Lee
SLSae Youn Lee
Sae Youn Lee
JKJin Sik Kim
Jin Sik Kim
Solution-based direct patterning on an elastomer substrate with meniscus-dragging deposition (MDD) enables fabrication of very thin carbon nanotube (CNT) layers in the nanometer scale (80–330 nm). To fabricate the CNT pattern with CNT solution, contact angle, electrical variation, mechanical stress, and surface cracks of elastomer substrate were analyzed to identify the optimal conditions of O2 treatment (treatment for 30 s with RF power of 50 W in O2 atmosphere of 50 sccm) and mixture ratio between Ecoflex and polydimethylsiloxane (PDMS) (Ecoflex:PDMS = 5:1). The type of mask for patterning of the CNT layer was determined through quantitative analysis for sharpness and uniformity of the fabricated CNT pattern. Through these optimization processes, the CNT pattern was produced on the elastomer substrate with selected mask (30 μm thick oriented polypropylene). The thickness of CNT pattern was also controlled to have hundreds nanometer and 500 μm wide rectangular and circular shapes were demonstrated. Furthermore, the change in the current and resistance of the CNT layer according to the applied strain on the elastomer substrate was analyzed. Our results demonstrated the potential of the MDD method for direct CNT patterning with high uniformity and the possibility to fabricate a stretchable sensor.

7 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
PJPark Ye Jin
Park Ye Jin
TDTHINH VIET DANG
THINH VIET DANG
UJUiseok Jeong
Uiseok Jeong
Moon Il KimMoon Il Kim
Moon Il Kim
JKJin Sik Kim
Jin Sik Kim
Nucleic acid aptamer-based research has focused on achieving the highest performance for bioassays. However, there are limitations in evaluating the affinity for the target analytes in these nucleic acid aptamer-based bioassays. In this study, we mainly propose graphene oxide (GO)-based electrical and optical analyses to efficiently evaluate the affinity between an aptamer and its target. We found that an aptamer-coupled GO-based chip with an electrical resistance induced by a field-effect transistor, with aptamers as low as 100 pM, can detect the target, thrombin, at yields as low as 250 pM within five minutes. In the optical approach, the fluorescent dye-linked aptamer, as low as 100 nM, was efficiently used with GO, enabling the sensitive detection of thrombin at yields as low as 5 nM. The cantilever type of mechanical analysis also demonstrated the intuitive aptamer–thrombin reaction in the signal using dBm units. Finally, a comparison of electrical and optical sensors’ characteristics was introduced in the attachment and detachment of aptamer to propose an efficient analysis that can be utilized for various aptamer-based research fields.