Byung Uk Lee

Prof. Byung Uk Lee

Aerosol and Bioengineering Lab, Department of Mechanical Engineering, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05029, Korea
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Journal of Aerosol Science
Verified
Journal Article
Closed access
KHKi Joon Heo
Ki Joon Heo
CLCheol Eon Lim
Cheol Eon Lim
HKHannah Bae Kim
Hannah Bae Kim
BLByung Uk Lee
Byung Uk Lee

1 September 2004 in Atmospheric Environment
Verified
Journal Article
Closed access
BLByung Uk Lee
Byung Uk Lee
MYMikhail Yermakov
Mikhail Yermakov
SGSergey A. Grinshpun
Sergey A. Grinshpun

1 June 2018 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
DCDong Yun Choi
Dong Yun Choi
KHKi Joon Heo
Ki Joon Heo
JKJuhee Kang
Juhee Kang
EAEun Jeong An
Eun Jeong An
SJSoo-Ho Jung
Soo-Ho Jung
JJJaehee Jung
Jaehee Jung

BLByung Uk Lee
Byung Uk Lee
This study calculates and elucidates the minimum size of respiratory particles that are potential carriers of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); furthermore, it evaluates the aerosol generation potential of SARS-CoV-2. The calculations are based on experimental results and theoretical models. In the case of maximum viral-loading derived from experimental data of COVID-19 patients, 8.97 × 10−5% of a respiratory fluid particle from a COVID-19 patient is occupied by SARS-CoV-2. Hence, the minimum size of a respiratory particle that can contain SARS-CoV-2 is calculated to be approximately 9.3 μm. The minimum size of the particles can decrease due to the evaporation of water on the particle surfaces. There are limitations to this analysis: (a) assumption that the viruses are homogeneously distributed in respiratory fluid particles and (b) considering a gene copy as a single virion in unit conversions. However, the study shows that high viral loads can decrease the minimum size of respiratory particles containing SARS-CoV-2, thereby increasing the probability of aerosol generation of the viruses. The aerosol generation theory created in this study for COVID-19 has the potential to be applied to other contagious diseases that are caused by respiratory infectious microorganisms.

1 January 2011 in Aerosol and Air Quality Research
Verified
Journal Article
Closed access
BLByung Uk Lee
Byung Uk Lee

1 November 2014 in Journal of Aerosol Science
Verified
Journal Article
Closed access
KHKi Joon Heo
Ki Joon Heo
HKHannah Bae Kim
Hannah Bae Kim
BLByung Uk Lee
Byung Uk Lee