Marianne Guillemot

Marianne Guillemot


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2017 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
MGMarianne Guillemot
Marianne Guillemot
BOBenoît Oury
Benoît Oury
SMSandrine Melin
Sandrine Melin
Polymers processed to produce plastic articles are subjected to temperatures between 150°C and 450°C or more during overheated processing and breakdowns. Heat-based processing of this nature can lead to emission of volatile organic compounds (VOCs) into the thermoplastic processing shop. In this study, laboratory experiments, qualitative and quantitative emissions measurement in thermoplastic factories were carried out. The first step was to identify the compounds released depending on the thermoplastic nature, the temperature and the type of process. Then a thermal degradation protocol that can extrapolate the laboratory results to industry scenarios was developed. The influence of three parameters on released thermal breakdown products was studied: the sample preparation methods—manual cutting, ambient, or cold grinding—the heating rate during thermal degradation—5, 10 20, and 50°C/min—and the decomposition method—thermogravimetric analysis and pyrolysis. Laboratory results were compared to atmospheric measurements taken at 13 companies to validate the protocol and thereby ensure its representativeness of industrial thermal processing. This protocol was applied to most commonly used thermoplastics to determine their thermal breakdown products and their thermal behaviour. Emissions data collected by personal exposure monitoring and sampling at the process emission area show airborne concentrations of detected compounds to be in the range of 0–3 mg/m3 under normal operating conditions. Laser cutting or purging operations generate higher pollution levels in particular formaldehyde which was found in some cases at a concentration above the workplace exposure limit.

7 August 2015 in Industrial & Engineering Chemistry Research
Verified
Journal Article
Closed access
MGMarianne Guillemot
Marianne Guillemot
BCBlandine Castel
Blandine Castel

10 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CGChristelle GHAZALY
Christelle GHAZALY
MHMarc HEBRANT
Marc HEBRANT
ELEddy Langlois
Eddy Langlois
BCBlandine Castel
Blandine Castel
MGMarianne Guillemot
Marianne Guillemot
Mathieu EtienneMathieu Etienne
Mathieu Etienne
Sensitive and selective personal exposure monitors are needed to assess ozone (O3) concentrations in the workplace atmosphere in real time for the analysis and prevention of health risks. Here, a cumulative gas sensor using visible spectroscopy for real-time O3 determination is described. The sensing chip is a mesoporous silica thin film deposited on transparent glass and impregnated with methylene blue (MB). The sensor is reproducible, stable for at least 50 days, sensitive to 10 ppb O3 (one-tenth of the occupational exposure limit value in France, Swiss, Canada, U.K., Japan, and the USA) with a measurement range tested up to 500 ppb, and insensitive to NO2 and to large variation in relative humidity. A model and its derivative as a function of time are proposed to convert in real time the sensor response to concentrations, and an excellent correlation was obtained between those data and reference O3 concentrations. This sensor is based on a relatively cheap sensing material and a robust detection system, and its analytical performance makes it suitable for monitoring real-time O3 concentrations in workplaces to promote a safer environment for workers.