Tian’an Jiang

Prof. Tian’an Jiang

Zhejiang University

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Clinical Gastroenterology and Hepatology
Verified
Journal Article
Closed access
BCBin Cheng
Bin Cheng
YZYueming Zhang
Yueming Zhang
QCQian Chen
Qian Chen
BSBo Sun
Bo Sun
ZDZhuang Deng
Zhuang Deng
GWGuiqi Wang
Guiqi Wang

15 October 2021 in European Radiology
Verified
Journal Article
Closed access
PDF file
JGJionghui Gu
Jionghui Gu
TTTong Tong
Tong Tong
CHChang He
Chang He
MXMin Xu
Min Xu
XYXin Yang
Xin Yang
KWKun Wang
Kun Wang

19 November 2022 in Cancer
Verified
Journal Article
Closed access
JGJionghui Gu
Jionghui Gu
TTTong Tong
Tong Tong
DXDong Xu
Dong Xu
FCFang Cheng
Fang Cheng
CFChengyu Fang
Chengyu Fang
TJTian’an Jiang
Tian’an Jiang

2 March 2022 in BMC Medicine
Verified
Journal Article
Open access
PDF file
TTTong Tong
Tong Tong
JGJionghui Gu
Jionghui Gu
DXDong Xu
Dong Xu
LSLing Song
Ling Song
QZQiyu Zhao
Qiyu Zhao
TJTian’an Jiang
Tian’an Jiang
Background: Accurate and non-invasive diagnosis of pancreatic ductal adenocarcinoma (PDAC) and chronic pancreatitis (CP) can avoid unnecessary puncture and surgery. This study aimed to develop a deep learning radiomics (DLR) model based on contrast-enhanced ultrasound (CEUS) images to assist radiologists in identifying PDAC and CP. Methods: Patients with PDAC or CP were retrospectively enrolled from three hospitals. Detailed clinicopathological data were collected for each patient. Diagnoses were confirmed pathologically using biopsy or surgery in all patients. We developed an end-to-end DLR model for diagnosing PDAC and CP using CEUS images. To verify the clinical application value of the DLR model, two rounds of reader studies were performed. Results: A total of 558 patients with pancreatic lesions were enrolled and were split into the training cohort (n=351), internal validation cohort (n=109), and external validation cohorts 1 (n=50) and 2 (n=48). The DLR model achieved an area under curve (AUC) of 0.986 (95% CI 0.975–0.994), 0.978 (95% CI 0.950–0.996), 0.967 (95% CI 0.917–1.000), and 0.953 (95% CI 0.877–1.000) in the training, internal validation, and external validation cohorts 1 and 2, respectively. The sensitivity and specificity of the DLR model were higher than or comparable to the diagnoses of the five radiologists in the three validation cohorts. With the aid of the DLR model, the diagnostic sensitivity of all radiologists was further improved at the expense of a small or no decrease in specificity in the three validation cohorts. Conclusions: The findings of this study suggest that our DLR model can be used as an effective tool to assist radiologists in the diagnosis of PDAC and CP.

24 April 2020 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
XQXiaoying Qiu
Xiaoying Qiu
YJYongluo Jiang
Yongluo Jiang
QZQiyu Zhao
Qiyu Zhao
CYChunhong Yan
Chunhong Yan
MHMin Huang
Min Huang
TJTian’an Jiang
Tian’an Jiang
Objectives: This work aimed to investigate whether quantitative radiomics imaging features extracted from ultrasound (US) can noninvasively predict breast cancer (BC) metastasis to axillary lymph nodes (ALNs).Methods: Presurgical B‐mode US data of 196 patients with BC were retrospectively studied. The cases were divided into the training and validation cohorts (n = 141 versus 55). The elastic net regression technique was used for selecting features and building a signature in the training cohort. A linear combination of the selected features weighted by their respective coefficients produced a radiomics signature for each individual. A radiomics nomogram was established based on the radiomics signature and US‐reported ALN status. In a receiver operating characteristic curve analysis, areas under the curves (AUCs) were determined for assessing the accuracy of the prediction model in predicting ALN metastasis in both cohorts. The clinical value was assessed by a decision curve analysis.Results: In all, 843 radiomics features per case were obtained from expert‐delineated lesions on US imaging in this study. Through radiomics feature selection, 21 features were selected to constitute the radiomics signature for predicting ALN metastasis. Area under the curve values of 0.778 and 0.725 were obtained in the training and validation cohorts, respectively, indicating moderate predictive ability. The radiomics nomogram comprising the radiomics signature and US‐reported ALN status showed the best performance for ALN detection in the training cohort (AUC, 0.816) but moderate performance in the validation cohort (AUC, 0.759). The decision curve showed that both the radiomics signature and nomogram displayed good clinical utility.Conclusions: This pilot radiomics study provided a noninvasive method for predicting presurgical ALN metastasis status in BC.

30 January 2020 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
GTGuo Tian
Guo Tian
DKDexing Kong
Dexing Kong
TJTian’an Jiang
Tian’an Jiang
LLLanjuan Li
Lanjuan Li