Timothy Burnett

Dr. Timothy Burnett


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Ultramicroscopy
Verified
Journal Article
Open access
TBTimothy Burnett
Timothy Burnett
RKR. Kelley
R. Kelley
BWB. Winiarski
B. Winiarski
LCL. Contreras
L. Contreras
MDM. Daly
M. Daly
PWPhilip John Withers
Philip John Withers
Ga(+) Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga(+) FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe(+) Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC-Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga(+) FIB milling WC-Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60nA at 30kV. Xe(+) PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography.

24 October 2011 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
TYT J Young
T J Young
MMMiguel Monclús
Miguel Monclús
TBTimothy Burnett
Timothy Burnett
WBW R Broughton
W R Broughton
SOS L Ogin
S L Ogin
PSP A Smith
P A Smith

16 April 2014 in Scientific Reports
Verified
Journal Article
Open access
TBTimothy Burnett
Timothy Burnett
SMS. A. McDonald
S. A. McDonald
AGA. Gholinia
A. Gholinia
RGR. Geurts
R. Geurts
MJM. Janus
M. Janus
PWPhilip John Withers
Philip John Withers
Increasingly researchers are looking to bring together perspectives across multiple scales, or to combine insights from different techniques, for the same region of interest. To this end, correlative microscopy has already yielded substantial new insights in two dimensions (2D). Here we develop correlative tomography where the correlative task is somewhat more challenging because the volume of interest is typically hidden beneath the sample surface. We have threaded together x-ray computed tomography, serial section FIB-SEM tomography, electron backscatter diffraction and finally TEM elemental analysis all for the same 3D region. This has allowed observation of the competition between pitting corrosion and intergranular corrosion at multiple scales revealing the structural hierarchy, crystallography and chemistry of veiled corrosion pits in stainless steel. With automated correlative workflows and co-visualization of the multi-scale or multi-modal datasets the technique promises to provide insights across biological, geological and materials science that are impossible using either individual or multiple uncorrelated techniques.

17 June 2019 in Nature Materials
Verified
Journal Article
Closed access
PDF file
TBTimothy Burnett
Timothy Burnett
PWPhilip John Withers
Philip John Withers

28 April 2011 in Nano Letters
Verified
Journal Article
Closed access
TBTimothy Burnett
Timothy Burnett
RYRositza Yakimova
Rositza Yakimova
OKOlga Kazakova
Olga Kazakova

23 January 2012 in Journal of the American Chemical Society
Verified
Journal Article
Open access
MLMan-Rong Li
Man-Rong Li
UAUmut Adem
Umut Adem
SMSean R. C. McMitchell
Sean R. C. McMitchell
ZXZhongling Xu
Zhongling Xu
CTChris I. Thomas
Chris I. Thomas
JCJohn B. Claridge
John B. Claridge
Combining long-range magnetic order with polarity in the same structure is a prerequisite for the design of (magnetoelectric) multiferroic materials. There are now several demonstrated strategies to achieve this goal, but retaining magnetic order above room temperature remains a difficult target. Iron oxides in the +3 oxidation state have high magnetic ordering temperatures due to the size of the coupled moments. Here we prepare and characterize ScFeO3 (SFO), which under pressure and in strain-stabilized thin films adopts a polar variant of the corundum structure, one of the archetypal binary oxide structures. Polar corundum ScFeO3 has a weak ferromagnetic ground state below 356 K—this is in contrast to the purely antiferromagnetic ground state adopted by the well-studied ferroelectric BiFeO3.