Ion Torrent and Ion Proton are semiconductor-based sequencing technologies that feature rapid sequencing speed and low upfront and operating costs, thanks to the avoidance of modified nucleotides and optical measurements. Despite of these advantages, however, Ion semiconductor sequencing technologies suffer much reduced sequencing accuracy at the genomic loci with homopolymer repeats of the same nucleotide. Such limitation significantly reduces its efficiency for the biological applications aiming at accurately identifying various genetic variants. In this study, we propose a Bayesian inference-based method that takes the advantage of the signal distributions of the electrical voltages that are measured for all the homopolymers of a fixed length. By cross-referencing the length of homopolymers in the reference genome and the voltage signal distribution derived from the experiment, the proposed integrated model significantly improves the alignment accuracy around the homopolymer regions. Besides improving alignment accuracy on homopolymer regions for semiconductor-based sequencing technologies with the proposed model, similar strategies can also be used on other high-throughput sequencing technologies that share similar limitations.
Clinical drug–drug interactions (DDIs) have been a major cause for not only medical error but also adverse drug events (ADEs). The published literature on DDI clinical toxicity continues to grow significantly, and high-performance DDI information retrieval (IR) text mining methods are in high demand. The effectiveness of IR and its machine learning (ML) algorithm depends on the availability of a large amount of training and validation data that have been manually reviewed and annotated. In this study, we investigated how active learning (AL) might improve ML performance in clinical safety DDI IR analysis. We recognized that a direct application of AL would not address several primary challenges in DDI IR from the literature. For instance, the vast majority of abstracts in PubMed will be negative, existing positive and negative labeled samples do not represent the general sample distributions, and potentially biased samples may arise during uncertainty sampling in an AL algorithm. Therefore, we developed several novel sampling and ML schemes to improve AL performance in DDI IR analysis. In particular, random negative sampling was added as a part of AL since it has no expanse in the manual data label. We also used two ML algorithms in an AL process to differentiate random negative samples from manually labeled negative samples, and updated both the training and validation samples during the AL process to avoid or reduce biased sampling. Two supervised ML algorithms, support vector machine (SVM) and logistic regression (LR), were used to investigate the consistency of our proposed AL algorithm. Because the ultimate goal of clinical safety DDI IR is to retrieve all DDI toxicity–relevant abstracts, a recall rate of 0.99 was set in developing the AL methods. When we used our newly proposed AL method with SVM, the precision in differentiating the positive samples from manually labeled negative samples improved from 0.45 in the first round to 0.83 in the second round, and the precision in differentiating the positive samples from random negative samples improved from 0.70 to 0.82 in the first and second rounds, respectively. When our proposed AL method was used with LR, the improvements in precision followed a similar trend. However, the other AL algorithms tested did not show improved precision largely because of biased samples caused by the uncertainty sampling or differences between training and validation data sets.
Cleavage and polyadenylation are essential processes that can impact many aspects of mRNA fate. Most eukaryotic genes have alternative polyadenylation (APA) events. While the heterogeneity of mRNA polyadenylation isoform choice has been studied in specific tissues, less attention has been paid to the neuronal heterogeneity of APA selection at single-nucleus resolution. APA is highly controlled during development and neuronal activation, however, to what extent APA events vary in a specific neuronal cell population and the regulatory mechanisms are still unclear. In this paper, we investigated dynamic APA usage in different cell types using snRNA-seq data of 1424 human brain cells generated by single-cell 3′ RNA sequencing. We found that distal APA sites are not only favored by global neuronal cells, but that their usage also varies between the principal types of neuronal cell populations (excitatory neurons and inhibitory neurons). A motif analysis and a gene functional analysis indicated the enrichment of RNA-binding protein (RBP) binding sites and neuronal functions for the set of genes with neuron-enhanced distal PAS usage. Our results revealed the extensive involvement of APA regulation in neuronal populations at the single-nucleus level, providing new insights into roles for APA in specific neuronal cell populations, as well as utility in future functional studies.
DNA methylation is a fundamental component of epigenetic modification, which is intimately involved in the regulation of gene expression. One important DNA methylation pathway reduces the abilities of transcription factors to bind to gene promoter regions. Although many experiments have been designed to measure genome-wide DNA methylation levels at high resolution, the meaning of these different DNA methylation levels on transcription factor binding abilities remains poorly understood. We have, therefore, developed a method to quantitatively explore the extent to which DNA methylation levels can significantly reduce or even abolish the binding of certain transcription factors, resulting in reduced or non-expression of flanking genes. This method allows transcription factors that are functionally active in gene expression to be investigated.
Motivation: Generally, bottom-up and top-down are two complementary approaches for proteoforms identification. The inference of proteoforms relies on searching mass spectra against an accurate proteoform sequence database. A customized protein sequence database derived by RNA-Seq data can be used to better identify the proteoform existed in a studied species. However, the quality of sequences in customized databases which constructed by different strategies affect the performances of mass spectrometry (MS) identification. Additionally, performances of identifications between bottom-up and top-down using customized databases are also needed to be evaluatedResults: Three customized databases were constructed with different strategies separately. Two of them were based on translating assembled transcripts with or without genomic annotation, and the third one is a variant-extending protein database. By testing with bottom-up and top-down MS data separately, a variant-extending protein database could identify not only the most number of spectra but also the alleles expressed at the same time in diploid cells. An assembled database could identify the spectrum missed in reference database and amino acid (AA) alterations existed in studied species.Availability and implementation: Experimental results demonstrated that the proteoform sequences in an annotated database are more suitable for identifying AA alterations and peptide sequences missed in reference database. An unannotated database instead of a reference proteome database gets an enough high sensitivity of identifying mass spectra. The variant-extending reference database is the most sensitive to identify mass spectra and single AA variantsSupplementary information: Supplementary data are available at Bioinformatics online.
Top-down mass spectrometry has unique advantages in identifying proteoforms with multiple post-translational modifications and/or unknown alterations. Most software tools in this area search top-down mass spectra against a protein sequence database for proteoform identification. When the species studied in a mass spectrometry experiment lacks its proteome sequence database, a homologous protein sequence database can be used for proteoform identification. The accuracy of homologous protein sequences affects the sensitivity of proteoform identification and the accuracy of mass shift localization. We tested TopPIC, a commonly used software tool for top-down mass spectral identification, on a top-down mass spectrometry data set of Escherichia coli K12 MG1655, and evaluated its performance using an Escherichia coli K12 MG1655 proteome database and a homologous protein database. The number of identified spectra with the homologous database was about half of that with the Escherichia coli K12 MG1655 database. We also tested TopPIC on a top-down mass spectrometry data set of human MCF-7 cells and obtained similar results. Experimental results demonstrated that TopPIC is capable of identifying many proteoform spectrum matches and localizing unknown alterations using homologous protein sequences containing no more than 2 mutations.