Gretchen Mahler

Dr. Gretchen Mahler

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in NanoImpact
Verified
Journal Article
Closed access
ZGZhongyuan Guo
Zhongyuan Guo
NMNicole J. Martucci
Nicole J. Martucci
FMFabiola Moreno-Olivas
Fabiola Moreno-Olivas
ETElad Tako
Elad Tako
GMGretchen Mahler
Gretchen Mahler

1 March 2016 in EBioMedicine
Verified
Journal Article
Open access
CSCourtney M. Sakolish
Courtney M. Sakolish
MEMandy B. Esch
Mandy B. Esch
JHJames J. Hickman
James J. Hickman
MSMichael L. Shuler
Michael L. Shuler
GMGretchen Mahler
Gretchen Mahler
Organ-on-a-chip devices have gained attention in the field of in vitro modeling due to their superior ability in recapitulating tissue environments compared to traditional multiwell methods. These constructed growth environments support tissue differentiation and mimic tissue-tissue, tissue-liquid, and tissue-air interfaces in a variety of conditions. By closely simulating the in vivo biochemical and biomechanical environment, it is possible to study human physiology in an organ-specific context and create more accurate models of healthy and diseased tissues, allowing for observations in disease progression and treatment. These chip devices have the ability to help direct, and perhaps in the distant future even replace animal-based drug efficacy and toxicity studies, which have questionable relevance to human physiology. Here, we review recent developments in the in vitro modeling of barrier tissue interfaces with a focus on the use of novel and complex microfluidic device platforms.

18 April 2018 in Nanotoxicology
Verified
Journal Article
Closed access
ZGZhongyuan Guo
Zhongyuan Guo
NMNicole J. Martucci
Nicole J. Martucci
YLYizhong Liu
Yizhong Liu
EYEusoo Yoo
Eusoo Yoo
Elad TakoElad Tako
Elad Tako
GMGretchen Mahler
Gretchen Mahler
The use of nanomaterials to enhance properties of food and improve delivery of orally administered drugs has become common, but the potential health effects of these ingested nanomaterials remain unknown. The goal of this study is to characterize the properties of silicon dioxide (SiO2) nanoparticles (NP) that are commonly used in food and food packaging, and to investigate the effects of physiologically realistic doses of SiO2 NP on gastrointestinal (GI) health and function. In this work, an in vitro model composed of Caco-2 and HT29-MTX co-cultures, which represent absorptive and goblet cells, was used. The model was exposed to well-characterized SiO2 NP for acute (4 h) and chronic (5 d) time periods. SiO2 NP exposure significantly affected iron (Fe), zinc (Zn), glucose, and lipid nutrient absorption. Brush border membrane intestinal alkaline phosphatase (IAP) activity was increased in response to nano-SiO2. The barrier function of the intestinal epithelium, as measured by transepithelial electrical resistance, was significantly decreased in response to chronic exposure. Gene expression and oxidative stress formation analysis showed NP altered the expression levels of nutrient transport proteins, generated reactive oxygen species, and initiated pro-inflammatory signaling. SiO2 NP exposure damaged the brush border membrane by decreasing the number of intestinal microvilli, which decreased the surface area available for nutrient absorption. SiO2 NP exposure at physiologically relevant doses ultimately caused adverse outcomes in an in vitro model.

27 June 2017 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
SDSudip Dahal
Sudip Dahal
PHPeter Huang
Peter Huang
BMBruce T. Murray
Bruce T. Murray
GMGretchen Mahler
Gretchen Mahler

1 January 2019 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
CSCourtney M. Sakolish
Courtney M. Sakolish
BPBrian Philip
Brian Philip
GMGretchen Mahler
Gretchen Mahler
Renal disease is a global problem with unsustainable health-care costs. There currently exists a lack of accurate human renal disease models that take into account the complex microenvironment of these tissues. Here, we present a reusable microfluidic model of the human proximal tubule and glomerulus, which allows for the growth of renal epithelial cells in a variety of conditions that are representative of renal disease states including altered glomerular filtration rate, hyperglycemia, nephrolithiasis, and drug-induced nephrotoxicity (cisplatin and cyclosporine). Cells were exposed to these conditions under fluid flow or in traditional static cultures to determine the effects of a dynamic microenvironment on the pathogenesis of these renal disease states. The results indicate varying stress-related responses (α-smooth muscle actin (α-SMA) expression, alkaline phosphatase activity, fibronectin, and neutrophil gelatinase-associated lipocalin secretion) to each of these conditions when comparing cells that had been grown in static and dynamic conditions, potentially indicating more realistic and sensitive predictions of human responses and a requirement for a more complex “fit for purpose” model.

1 July 2017 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
SMSara G. Mina
Sara G. Mina
PHPeter Huang
Peter Huang
BMBruce T. Murray
Bruce T. Murray
GMGretchen Mahler
Gretchen Mahler
Tumor development is influenced by stromal cells in aspects including invasion, growth, angiogenesis, and metastasis. Activated fibroblasts are one group of stromal cells involved in cancer metastasis, and one source of activated fibroblasts is endothelial to mesenchymal transformation (EndMT). EndMT begins when the endothelial cells delaminate from the cell monolayer, lose cell-cell contacts, lose endothelial markers such as vascular endothelial-cadherin (VE-cadherin), gain mesenchymal markers like alpha-smooth muscle actin (α-SMA), and acquire mesenchymal cell-like properties. A three-dimensional (3D) culture microfluidic device was developed for investigating the role of steady low shear stress (1 dyne/cm2) and altered extracellular matrix (ECM) composition and stiffness on EndMT. Shear stresses resulting from fluid flow within tumor tissue are relevant to both cancer metastasis and treatment effectiveness. Low and oscillatory shear stress rates have been shown to enhance the invasion of metastatic cancer cells through specific changes in actin and tubulin remodeling. The 3D ECM within the device was composed of type I collagen and glycosaminoglycans (GAGs), hyaluronic acid and chondroitin sulfate. An increase in collagen and GAGs has been observed in the solid tumor microenvironment and has been correlated with poor prognosis in many different cancer types. In this study, it was found that ECM composition and low shear stress upregulated EndMT, including upregulation of mesenchymal-like markers (α-SMA and Snail) and downregulated endothelial marker protein and gene expression (VE-cadherin). Furthermore, this novel model was utilized to investigate the role of EndMT in breast cancer cell proliferation and migration. Cancer cell spheroids were embedded within the 3D ECM of the microfluidic device. The results using this device show for the first time that the breast cancer spheroid size is dependent on shear stress and that the cancer cell migration rate, distance, and proliferation are induced by EndMT-derived activated fibroblasts. This model can be used to explore new therapeutics in a tumor microenvironment.