Jinwon Shin

Prof. Jinwon Shin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2024 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
SKSeungki Kim
Seungki Kim
JSJinwon Shin
Jinwon Shin
WKWoosuk Kim
Woosuk Kim
This study was conducted to evaluate the seismic performance of an exterior precast concrete (PC) beam–column joint with ultra-high-performance fiber-reinforced concrete (UHPFRC). Currently, 45 MPa non-shrinkage mortar is used as grouting for the connection between PC beams and columns. In this study, PC joint specimens were designed using 45 MPa non-shrinkage mortar and 120 MPa UHPFRC as a grouting agent for connecting PC members. The shear reinforcement effect of UHPFRC was confirmed to reduce shear cracks in the joint core; this trend was similar in the specimens with reduced shear rebars. The maximum moment of the test specimen with the corbel was slightly increased, but there was no significant difference, and the failure pattern also showed similar results to the specimen without the corbel. In the test specimen to which the U-shaped beam was applied, the attachment surface of ultra-high-performance concrete and normal concrete were separated, and a large decrease in strength was observed. Considering workability, U-shaped beam do not seem to have any major merits in general, such as increased strength and difficulty in manufacturing, and it was judged that it was effective to separate the PC beams from the column face through corbels. Shear reinforcement through UHPFRC is effective in relieving congestion by reducing shear reinforcement bars at the joint, and it is judged that it can be used as PC joint grouting due to its excellent fluidity.

1 July 2019 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JSJinwon Shin
Jinwon Shin
AWAndrew S. Whittaker
Andrew S. Whittaker
When a blast wave impinges on the front face of a structure, rarefaction waves are formed along its free edges and propagate toward the center of the front face, and reduce the reflected overpressure: an effect known as clearing. Standards, guidelines and textbooks provide empirical equations to account for the effect of clearing. The clearing time is that instant at which the reflected overpressure decreases to the stagnation pressure. These empirical equations were used to calculate the reflected impulse for the design of a building loaded by a far-field detonation of a nuclear weapon. For such a detonation and a low-rise building, the incident shock front can be assumed to be vertical. This assumption is inappropriate for near-field detonations of high explosives because the reflected overpressure across the front face of a target varies with arrival time, standoff distance, and angle of incidence. There is little information on the effect of clearing in the literature for near-field (small-scaled distance) detonations. This paper presents the results of a computational fluid dynamics analysis of a validated numerical model that examines blast-wave clearing with an emphasis on near-field detonations. The widely used empirical equations for calculating clearing time are incorrect for near-field detonations and should not be used in design practice. Clearing in the near field is negligible and should be ignored for the purpose of design. Clearing in the far field will only be important for structural components of a width that is too narrow to be of practical importance. The physical experiments of two previous studies were simulated to gain insight into the development of the empirical equations that characterize the effects of clearing.

26 March 2024 in Tunnelling and Underground Space Technology
Verified
Journal Article
Open access
JSJinwon Shin
Jinwon Shin
SPSeungki Pang
Seungki Pang
WKWoosuk Kim
Woosuk Kim

4 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJinwon Shin
Jinwon Shin
JLJineung Lee
Jineung Lee
YLYongjae Lee
Yongjae Lee
BKByungyun Kim
Byungyun Kim
This paper presents an experimental and numerical study to investigate the structural performance of a steel deck-plate system bolted with truss girder. This system has been proposed herein to resolve the issues caused by welding. Structural tests for six full-scale specimens were performed to ensure the structural safety of the proposed system based on design criteria for deflection. Local responses with an emphasis on the failure modes of the system were also assessed using the measured strains at the locations where stresses are localized. Numerical models for all test specimens were developed with the material test data and were validated based on the test results. The structural behaviors of the proposed system, not confirmed in the tests, were further examined using numerical simulations, with a focus on the failure mechanism between the numerical predictions and the test results.

1 February 2020 in Applied Mathematics and Computation
Verified
Journal Article
Closed access
JKJinkyu Kim
Jinkyu Kim
HLHyeonseok Lee
Hyeonseok Lee
JSJinwon Shin
Jinwon Shin

27 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJinwon Shin
Jinwon Shin
SHSeong-Hoon Hwang
Seong-Hoon Hwang
JKJinkyu Kim
Jinkyu Kim
This paper presents a numerical study to investigate the blast performance of a plate-reinforced moment-resisting connection using a large concrete filled tubular (CFT) column with dimensions of 1000 × 1000 mm and a thickness of 40 mm. A steel H-section with dimensions of 700 × 300 × 13 × 24 mm is used for beam. The plate-reinforced large CFT connection is analyzed numerically using a finite element code to evaluate its blast resistance. The methodology of modeling the connection is validated based on a past experimental study and verified using an alternate finite element code. Five improvised explosive devices (IED) are considered as blast loadings. The blast resistance of the proposed connection against the IED attacks is investigated based on the design criteria specified in the U.S. government document, UFC 3-340-02, and in comparison to that of a widely used through-diaphragm moment connection. Local failure modes in the vicinity of the connections are also examined. Recommendation is provided for design practice.