Bias thermal sensitivity is a significant performance parameter of a silicon resonant accelerometer (SRA) and is normally used to evaluate the degree of engineering practicability. Theoretical analysis demonstrates that temperature-induced stress is the dominant factor that determines the bias temperature drift of the custom-designed SRA. To solve this issue, this paper presents an SRA embedded in an isolation frame with stress insensitive anchor that prevents the resonant beams suffering from the thermal stress along the sense axis and thus improving the bias stability. Moreover, a high sensitivity device is achieved by integrating the vibrating beams with the comb fingers without conventional additional mass design. The experimental results show that the nominal resonant frequency of the SRA is around 93 kHz with the sensitivity and nonlinearity of 223.7 Hz/g and 5.1‰. The thermal sensitivities of the two resonant beams are −27.6 ppm/°C and −28.8 ppm/°C, respectively, which can be considered as the results owing to temperature change of the Young’s modulus without the thermal stress effect. The bias thermal sensitivity and the stability (1σ) after compensation are tested to be approximately 0.7 mg/°C and 1 mg over the temperature range from −40 °C to 60 °C with ±80 g measurement range.
Bias warm-up time is the time required for MEMS gyroscopes to reach a relatively stable state with specified performance after the power supply is turned on, is a critical factor for short time-of-flight navigation applications. This paper demonstrates an effective method to improve the bias warm-up time of a custom-designed MEMS gyroscope operating in split-mode based on open-loop readout scheme with active suppression of the coupling stiffness (ASCS). A semi-quantitative mathematical model for the temperature sensitivity of the bias is established that indicates the resonant frequency of the primary mode, the frequency difference and the coupling stiffness between the primary and sense modes together with the demodulation phase error, and these are the main factors that affect bias warm-up time. Of all these parameters, the stiffness coupling variation contributes the most to the start-up warm-up time, followed by the phase error drift. The experimental result shows that the bias warm-up time decreases from 2000 to 2 s under the condition that the bias stability (1σ) falls into about 10 deg/h within an hour of testing time using closed-loop control for the coupling stiffness, resulting in a reduction of three orders of magnitude. In addition, the bias instability of the gyroscope is improved two-fold from 4 to 2 deg/h with ASCS.
6 March 2023 in IEEE Transactions on Industrial Electronics
Quality factor has played a crucial role in determining the temperature and antishock performance of a microelectromechanical system gyroscope. This article presents an innovative approach to enhance the thermal stability of quality factor for a micro resonant sensors based on Joule effect in situ dynamic tuning for the first time. By unitizing an active control loop that adjusts the dissipation energy of a resistive element connected to the mechanical structure via monitoring the driving voltage, the device damping can be effectively tuned in real-time, thus stabilizing the quality factor. The proposed method is demonstrated on a vacuumed sealed monolithic dual-axis gyroscope. The results show that the relative variation of the Q-factor significantly reduced by more than 3000× down to ∼150 ppm from −40 °C to +60 °C, which achieves only ∼30 ppm of driving voltage stability with ∼3500× reduction. Benefiting from the quality factor precise control capability, the electrical coupling from the drive mode to the sense mode is, therefore, suppressed, exhibiting more than three-fold times improvement of the zero bias thermal drift over 100 °C range. This technique is also promising for enhancing the antishock performance.
16 November 2021 in IEEE Transactions on Industrial Electronics
This articledemonstrates the developments toward a high-performance monolithic wheeled structure horizontal dual-axis [pitch ( X- axis) and roll ( Y -axis)] microelectromechanical system (MEMS) gyroscope based on off-plane coupling suppression silicon gratings. Gyroscopes have been fabricated with a silicon-on-glass fabrication process with vacuum sealed in metal packaging. The featured gyroscope operates in split mode with the bandwidths of two axes devices both of ∼70 Hz. By unitizing two individual active restraining control loops that adjust the quadrature amplitude via differentially biasing the silicon gratings in real time, the off-plane mechanical couplings of the two sense modes are significantly reduced by ∼95 and ∼30 times, which enables ∼25-fold and ∼56-fold improvements in the bias instability (BI) for a typical dual-axis device. Tactical-grade performances are achieved for both the X- axis and Y- axis gyroscopes with angle random walk of 0.02 deg/√h and 0.045 deg/√h along with in-run BI of 0.26 deg/h and 0.65 deg/h, respectively, without any temperature compensation. The current preliminary results show great potential to achieve navigation grade precision by employing the mode-matching technique in the future. The use of silicon gratings for out-of-plane coupling reduction also provides an effective way to build a high-performance planar monolithic chip inertial measurement unit.
Small initial frequency split is preferred to reduce the complexity of control circuits and enhance the device sensitivity for mode‐matching MEMS gyroscopes. A microring gyroscope with cascaded rectangular beams as supporting springs fabricated by (100) single crystal silicon (SCS) is presented. Frequency split due to the anisotropic of Young's modulus of (100) SCS is geometrically compensated by adjusting the width of cascaded springs and adding an extra mass. The rectangular beams are designed to be wide enough to improve the immunity to fabrication imperfections, obtaining good manufacturing repeatability. The proposed method can largely attenuate the frequency difference of the gyroscope by using (100) SCS, which can reduce the processing cost and be easily integrated with CMOS circuit compared with (111) SCS. The test results show that the average initial frequency split of 15 different devices is 5.1 Hz for the ∼10,430 Hz resonant frequency. The minimum and maximum splits are 2.3 Hz (0.022%) and 7.3 Hz (0.069%), respectively, with the standard deviation of 1.3 Hz.
24 February 2023 in IEEE Transactions on Semiconductor Manufacturing
Laser trimming promises an increasing yield in microfabrication for the high performance Micro Electro-Mechanical Systems (MEMS) resonant devices by overcoming manufacturing tolerances and tuning sensors or actuators for certain operating conditions. How to achieve a high precision and efficiency trimming at low cost is the critical issue that the technical communities are most concerned. In this paper, we proposed an automatic laser trimming system for silicon MEMS devices based on a picosecond laser source and image recognition technique (IRT). Through the design of laser focusing optical path and coaxial imaging optical path, the observation of laser machining process is realized. A set of picosecond laser trimming parameters is determined by experiments, which enables a 4um width trench on the silicon resonator. Compared with the femtosecond laser trimming systems, the cost of the pico-laser system is reduced by more than 60%. The shape matching algorithm based on OpenCV and the chord-to-point distance accumulation (CPDA) algorithm for MEMS resonators image measurement solve the problem of inefficiency of manual trimming for complex resonators. A dual-mass tuning fork resonator is used to demonstrate the feasibility of the trimming approach. It is shown that the system realizes a fine-tuning (< 0.3Hz) of the resonant frequencies. The trimming time of a single device using the automatic trimming method is reduced from more than 1 hour manual trimming to less than 1 minute. Finally, the structural stiffness imbalance of tuning fork resonator caused by the manufacturing error is eliminated, which verifies the feasibility of the system.