There is a growing interest in monitoring muscle oxygen saturation (SmO2), which is a localized measure of muscle oxidative metabolism and can be acquired continuously and noninvasively using near‐infrared spectroscopy (NIRS) methods. Most NIRS systems are cumbersome, expensive, fiber coupled devices, with use limited to lab settings. A novel, low cost, wireless, wearable has been developed for use in athletic training. In this study, we evaluate the advantages and limitations of this new simple continuous‐wave (CW) NIRS device with respect to a benchtop, frequency‐domain near‐infrared spectroscopy (FDNIRS) system. Oxygen saturation and hemoglobin/myoglobin concentration in the exercising muscles of 17 athletic individuals were measured simultaneously with the two systems, while subjects performed an incremental test on a stationary cycle ergometer. In addition, blood lactate concentration was measured at the end of each increment with a lactate analyzer. During exercise, the correlation coefficients of the SmO2 and hemoglobin/myoglobin concentrations between the two systems were over 0.70. We also found both systems were insensitive to the presence of thin layers of varying absorption, mimicking different skin colors. Neither system was able to predict the athletes’ lactate threshold power accurately by simply using SmO2 thresholds. Instead, the proprietary software of the wearable device was able to predict the athletes’ lactate threshold power within half of one power increment of the cycling test. These results indicate this novel wearable device may provide a physiological indicator of athlete's exertion.
Investigating the cerebral physiology of healthy term newborns’ brains is important for better understanding perinatal brain injuries, of which the most common etiologies are hypoxia and ischemia. Hence, cerebral blood flow and cerebral oxygenation are important biomarkers of brain health. In this study, we employed a hybrid diffuse optical system consisting of diffuse correlation spectroscopy (DCS) and frequency-domain near infrared spectroscopy (FDNIRS) to measure hemoglobin concentration, oxygen saturation, and indices of cerebral blood flow and metabolism. We measured 30 term infants to assess the optical and physiological characteristics of the healthy neonatal brain in the frontal, temporal, and parietal lobes. We observed higher metabolism in the right hemisphere compared to the left and a positive correlation between gestational age and the level of cerebral hemoglobin concentration, blood volume, and oxygen saturation. Moreover, we observed higher cerebral blood flow and lower oxygen saturation in females compared to males. The delayed maturation in males and the sexual dimorphism in cerebral hemodynamics may explain why males are more vulnerable to perinatal brain injuries than females.
Real-time noninvasive monitoring of cerebral blood flow during surgery could improve the morbidity and mortality rates associated with hypothermic circulatory arrests (HCA) in adult cardiac patients. In this study, we used a combined frequency domain near-infrared spectroscopy (FDNIRS) and diffuse correlation spectroscopy (DCS) system to measure cerebral oxygen saturation (SO 2 ) and an index of blood flow (CBF i ) in 12 adults going under cardiac surgery with HCA. Our measurements revealed that a negligible amount of blood is delivered to the brain during HCA with retrograde cerebral perfusion (RCP), indistinguishable from HCA-only cases (CBF i drops of 91% ± 3% and 96% ± 2%, respectively) and that CBF i drops for both are significantly higher than drops during HCA with antegrade cerebral perfusion (ACP) (p = 0.003). We conclude that FDNIRS-DCS can be a powerful tool to optimize cerebral perfusion, and that RCP needs to be further examined to confirm its efficacy, or lack thereof.
We developed a stand-alone multi-distance multi-wavelength diffuse correlation spectroscopy able to simultaneously measure tissue optical proprieties and blood flow, by taking advantage of both the light intensity decay over source-detector separations and the autocorrelation at three wavelengths.