Tomislav Senčić

Dr. Tomislav Senčić

Faculty of Engineering, University of Rijekadisabled, Rijeka, Croatia
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Tomislav SenčićTomislav Senčić
Tomislav Senčić
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
Paolo BlecichPaolo Blecich
Paolo Blecich
IBIgor Bonefačić
Igor Bonefačić
A two-dimensional computational fluid dynamics (2D CFD) simulation of a low-speed two-stroke marine engine simulation was performed in order to investigate the performance of 2D meshes that allow the use of more complex chemical schemes and pollutant formation analysis. Various mesh density simulations were compared with a 3D mesh simulation and with the experimentally obtained cylinder pressure. A heavy fuel model and a soot model were implemented in the software. Finally, the influences of three water injection strategies were simulated and evaluated in order to investigate the capability of the model and the influence of water injection on NOx formation, soot formation, and engine performance. We conclude that the direct water injection strategy reduces NOx emissions without adversely affecting the engine performance or soot emissions. The other two strategies—Intake air humidification and direct injection of fuel–water emulsion—reduced NOx emissions but at the cost of higher soot emissions or reduced engine performance.

2 July 2018 in Modelling and Simulation in Engineering
Verified
Journal Article
Open access
PDF file
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
Tomislav SenčićTomislav Senčić
Tomislav Senčić
BŽBožica Žarković
Božica Žarković
Developed power variation of turbogenerator (TG) steam turbine, which operates at the conventional LNG carrier, allows insight into the change in turbine exergy efficiency and exergy destruction during the increase in turbine power. Measurements of required operating parameters were performed in eight different TG steam turbine operating points during exploitation. Turbine exergy efficiency increases from turbine power of 500 kW up to 2700 kW, and maximum exergy efficiency was obtained at 70.13% of maximum turbine developed power (at 2700 kW) in each operating point. From turbine developed power of 2700 kW until the maximum power of 3850 kW, exergy efficiency decreases. Obtained change in TG turbine exergy efficiency is caused by an uneven intensity of increase in turbine developed power and steam mass flow through the turbine. TG steam turbine exergy destruction change is directly proportional to turbine load and to steam mass flow through the turbine—higher steam mass flow results in a higher turbine load which leads to the higher exergy destruction and vice versa. The higher share of turbine developed power and the lower share of turbine exergy destruction in the TG turbine exergy power inlet lead to higher turbine exergy efficiencies. At each observed operating point, turbine exergy efficiency in exploitation is lower when compared to the maximum obtained one for 8.39% to 12.03%.

10 January 2022 in Processes
Verified
Journal Article
Open access
PDF file
Tomislav SenčićTomislav Senčić
Tomislav Senčić
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
VMVedran Medica-Viola
Vedran Medica-Viola
IWIgor Wolf
Igor Wolf
The scavenging process is an important part of the two-stroke engine operation. Its efficiency affects the global engine performance such as power, fuel consumption, and pollutant emissions. Slow speed marine diesel engines are uniflow scavenged, which implies inlet scavenging ports on the bottom of the liner and an exhaust valve on the top of the cylinder. A CFD model of such an engine process was developed with the OpenFOAM software tools. A 12-degree sector of the mesh was used corresponding to one of the 30 scavenging ports. A mesh sensitivity test was performed, and the cylinder pressure was compared to experimental data for the analyzed part of the process. The scavenging performances were analyzed for real operation parameters. The influence of the scavenge air pressure and inlet ports geometric orientation was analyzed. The scavenging process is analyzed by means of a passive scalar representing fresh air in the cylinder. Isosurfaces that show the concentration of fresh air were presented. The variation of oxygen and carbon dioxide with time and the axial and angular momentum in the cylinder were calculated. Finally, the scavenging performance for the various operation parameters was evaluated by means of scavenging efficiency, charging efficiency, trapping efficiency, and delivery ratio. It was found that the scavenging efficiency decreases with the engine load due to the shorter time for the process. The scavenging efficiency increases with the pressure difference between the exhaust and scavenging port, and the scavenging efficiency decreases with the increase in the angle of the scavenging ports. It was concluded that smaller angles than the industry standard of 20° could be beneficial to the scavenging efficiency. In the investigation, the charging efficiency ranged from 0.91 to over 0.99, the trapping efficiency ranged from 0.54 to 0.83, the charging efficiency ranged from 0.78 to 0.92, and the delivery ratio ranged from 1.21 to 2.03.

20 June 2018 in Pomorstvo
Verified
Journal Article
Open access
PDF file
Vedran MrzljakVedran Mrzljak
Vedran Mrzljak
Jasna Prpic-OrsicJasna Prpic-Orsic
Jasna Prpic-Orsic
Tomislav SenčićTomislav Senčić
Tomislav Senčić
In this paper is presented an analysis of main and auxiliary steam energy flow streams from steam generators during the increase in steam system load at conventional LNG carrier. During the steam system load increase was presented...

7 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Paolo BlecichPaolo Blecich
Paolo Blecich
IBIgor Bonefačić
Igor Bonefačić
Tomislav SenčićTomislav Senčić
Tomislav Senčić
IWIgor Wolf
Igor Wolf
This study analyzes the record electricity consumption in Croatia during the July 2024 heatwave and evaluates how the increased deployment of onshore wind and solar photovoltaics (PV) could mitigate a similar event in the future. Electricity demand and generation patterns under current (2024) and projected (2030) scenarios have been simulated using a sub-hourly power system model. The findings show that during the July 2024 heatwave, Croatia imported 35% of the electricity, with prices exceeding 400 €/MWh during peak hours. By 2030, the expanded wind and solar PV sectors (1.5 GW each) will increase the renewable share from 38.8% in July 2024 to 54.7% in July 2030. On the annual level, renewable energy generation increases from 53.8% in 2024 up to 66.9% in 2030. As result, the carbon intensity of the power sector will reduce from 223 gCO2eq/kWhel in 2024 to 197 gCO2eq/kWhel in 2030. The share of fossil fuel generation will increase slightly, from 19.7% in 2024 to 22% in 2030, but more significantly in the summer to meet the heatwave-induced electricity demand. Besides that, short-term energy storage of 2 GWh (400 MW discharge over 5 h) could effectively manage evening peak demands after solar PV ceases production.

25 September 2018 in Tehnički glasnik
Verified
Journal Article
Open access
PDF file
Paolo BlecichPaolo Blecich
Paolo Blecich
IWIgor Wolf
Igor Wolf
Tomislav SenčićTomislav Senčić
Tomislav Senčić
IBIgor Bonefačić
Igor Bonefačić
This paper presents a numerical investigation of heat and mass transfer inside a wet cooling tower with forced air draft, which find application in energy process industries and oil refineries. The mathematical model consists of mass, momentum and energy conservation equations, water droplet trajectories and their interaction with the gas phase, the computational domain and boundary conditions. Numerical distributions of air velocity, air temperatures, water vapor fractions and evaporation rates are shown and discussed. The wet cooling tower achieves an efficiency of around 80%, which can be improved by optimizing the value of the water droplet size, nozzle spray angle and water-to-air flow rate ratio. The water droplet size has a dominant effect on the cooling tower efficiency, whereas small droplets improve the efficiency up to 10%. On the other hand, the spray angle and the water-to-air ratio lead to slight improvements, about 2-3% in the best case.