Advancing studies of neural network dynamics and developments of closed-loop neural interfaces requires the ability to simultaneously stimulate and record the neural cells. Recording adjacent to or at the stimulation site produces artifact signals that are orders of magnitude larger than the neural responses of interest. These signals often saturate the recording amplifier causing distortion or loss of short-latency evoked responses. This paper proposes a method to cancel the artifact in simultaneous neural recording and stimulation on the same electrode. By combining a novel hardware architecture with concurrent software processing, the design achieves neural signal recovery in a wide range of conditions. The proposed system uniquely demonstrates same-electrode stimulation and recording, with neural signal recovery in presence of stimulation artifact 100 dB larger in magnitude than the underlying signals. The system is tested both in vitro and in vivo, during concurrent stimulation and recording on the same electrode. In vivo results in a rodent model are compared to recordings made by a commercial neural amplifier system connected in parallel.
Potentiation of synaptic activity in spinal networks is reflected in the magnitude of modulation of motor responses evoked by spinal and cortical input. After spinal cord injury, motor evoked responses can be facilitated by pairing cortical and peripheral nerve stimuli. To facilitate synaptic potentiation of cortico-spinal input with epidural electrical stimulation, we designed a novel neuromodulation method called dynamic stimulation (DS), using patterns derived from hind limb EMG signal during stepping. DS was applied dorsally to the lumbar enlargement through a high-density epidural array composed of independent platinum-based micro-electrodes. In fully anesthetized intact adult rats, at the interface array/spinal cord, the temporal and spatial features of DS neuromodulation affected the entire lumbosacral network, particularly the most rostral and caudal segments covered by the array. DS induced a transient (at least 1 min) increase in spinal cord excitability and, compared to tonic stimulation, generated a more robust potentiation of the motor output evoked by single pulses applied to the spinal cord. When sub-threshold pulses were selectively applied to a cortical motor area, EMG responses from the contralateral leg were facilitated by the delivery of DS to the lumbosacral cord. Finally, based on motor-evoked responses, DS was linked to a greater amplitude of motor output shortly after a calibrated spinal cord contusion. Compared to traditional tonic waveforms, DS amplifies both spinal and cortico-spinal input aimed at spinal networks, thus significantly increasing the potential and accelerating the rate of functional recovery after a severe spinal lesion.
Implantable functional electrical stimulation (IFES) has demonstrated its effectiveness as an alternative treatment option for diseases incurable pharmaceutically (e.g., retinal prosthesis, cochlear implant, spinal cord implant for pain relief). However, the development of IFES for gastrointestinal (GI) tract modulation is still limited due to the poorly understood GI neural network (gut–brain axis) and the fundamental difference among activating/monitoring smooth muscles, skeletal muscles and neurons. This inevitably imposes different design specifications for GI implants. This paper thus addresses the design requirements for an implant to treat GI dysmotility and presents a miniaturized wireless implant capable of modulating and recording GI motility. This implant incorporates a custom-made system-on-a-chip (SoC) and a heterogeneous system-in-a-package (SiP) for device miniaturization and integration. An in vivo experiment using both rodent and porcine models is further conducted to validate the effectiveness of the implant.
Knowledge of the bio-impedance and its equivalent circuit model at the electrode-electrolyte/tissue interface is important in the application of functional electrical stimulation. Impedance can be used as a merit to evaluate the proximity between electrodes and targeted tissues. Understanding the equivalent circuit parameters of the electrode can further be leveraged to set a safe boundary for stimulus parameters in order not to exceed the water window of electrodes. In this paper, we present an impedance characterization technique and implement a proof-of-concept system using an implantable neural stimulator and an off-the-shelf microcontroller. The proposed technique yields the parameters of the equivalent circuit of an electrode through large signal analysis by injecting a single low-intensity biphasic current stimulus with deliberately inserted inter-pulse delay and by acquiring the transient electrode voltage at three well-specified timings. Using low-intensity stimulus allows the derivation of electrode double layer capacitance since capacitive charge-injection dominates when electrode overpotential is small. Insertion of the inter-pulse delay creates a controlled discharge time to estimate the Faradic resistance. The proposed method has been validated by measuring the impedance of a) an emulated Randles cells made of discrete circuit components and b) a custom-made platinum electrode array in-vitro, and comparing estimated parameters with the results derived from an impedance analyzer. The proposed technique can be integrated into implantable or commercial neural stimulator system at low extra power consumption, low extra-hardware cost, and light computation.