Chia-Tai Chan

Dr. Chia-Tai Chan

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2015 in Sensors
Verified
Journal Article
Open access
PDF file
KCKun-Hui Chen
Kun-Hui Chen
PCPo-Chao Chen
Po-Chao Chen
KLKai-Chun Liu
Kai-Chun Liu
CCChia-Tai Chan
Chia-Tai Chan
Since the knee joint bears the full weight load of the human body and the highest pressure loads while providing flexible movement, it is the body part most vulnerable and susceptible to osteoarthritis. In exercise therapy, the early rehabilitation stages last for approximately six weeks, during which the patient works with the physical therapist several times each week. The patient is afterwards given instructions for continuing rehabilitation exercise by him/herself at home. This study develops a rehabilitation exercise assessment mechanism using three wearable sensors mounted on the chest, thigh and shank of the working leg in order to enable the patients with knee osteoarthritis to manage their own rehabilitation progress. In this work, time-domain, frequency-domain features and angle information of the motion sensor signals are used to classify the exercise type and identify whether their postures are proper or not. Three types of rehabilitation exercise commonly prescribed to knee osteoarthritis patients are: Short-Arc Exercise, Straight Leg Raise, and Quadriceps Strengthening Mini-squats. After ten subjects performed the three kinds of rehabilitation activities, three validation techniques including 10-fold cross-validation, within subject cross validation, and leave-one-subject cross validation are utilized to confirm the proposed mechanism. The overall recognition accuracy for exercise type classification is 97.29% and for exercise posture identification it is 88.26%. The experimental results demonstrate the feasibility of the proposed mechanism which can help patients perform rehabilitation movements and progress effectively. Moreover, the proposed mechanism is able to detect multiple errors at once, fulfilling the requirements for rehabilitation assessment.

22 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
CCChih-Yen Chiang
Chih-Yen Chiang
KCKun-Hui Chen
Kun-Hui Chen
KLKai-Chun Liu
Kai-Chun Liu
SHSteen Hsu
Steen Hsu
CCChia-Tai Chan
Chia-Tai Chan
Total knee arthroplasty (TKA) is the most common treatment for degenerative osteoarthritis of that articulation. However, either in rehabilitation clinics or in hospital wards, the knee range of motion (ROM) can currently only be assessed using a goniometer. In order to provide continuous and objective measurements of knee ROM, we propose the use of wearable inertial sensors to record the knee ROM during the recovery progress. Digitalized and objective data can assist the surgeons to control the recovery status and flexibly adjust rehabilitation programs during the early acute inpatient stage. The more knee flexion ROM regained during the early inpatient period, the better the long-term knee recovery will be and the sooner early discharge can be achieved. The results of this work show that the proposed wearable sensor approach can provide an alternative for continuous monitoring and objective assessment of knee ROM recovery progress for TKA patients compared to the traditional goniometer measurements.

1 October 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KLKai-Chun Liu
Kai-Chun Liu
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
SHSteen Jun-Ping Hsu
Steen Jun-Ping Hsu
CCChia-Tai Chan
Chia-Tai Chan
Falls are a leading health risk for the elderly. Various wearable-based fall detection systems based on machine learning models have been developed to provide emergency alarms and services to improve safety and health-related quality of life. To support long-term healthcare services, the appropriate sampling rate, which plays a vital role in a fall detection system, must be investigated to guarantee performance accuracy and energy efficiency. Intuitively, decreasing the sampling rate of sensor nodes can provide computing and energy savings. However, there is lack of research exploring the performance accuracy of fall detection systems in terms of sampling rate, especially for machine learning models. In this work, the effects of decreasing sampling rates (ranging from 200/128 Hz to 3 Hz) on wearable-based fall detection systems are investigated based on four machine learning models: Support Vector Machine (SVM), k-Nearest Neighbor (k-NN), Naive Bayes (NB), and Decision Tree (DT). Two emulated fall datasets, the SisFall public dataset and the proposed dataset of this study, are used to allow an objective investigation of sampling rates. The findings show that fall detection systems based on SVM modeling and a radial basis function could achieve at least 98% and 97% accuracy, with sampling rates of 11.6 Hz and 5.8 Hz, respectively. Overall, the experimental results demonstrate that a sampling rate of 22 Hz is sufficient for most machine learning models to support wearable-based fall detection systems (accuracy ≥ 97%).

1 July 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
CSChien-Lung Shen
Chien-Lung Shen
THTzu-Hao Huang
Tzu-Hao Huang
PHPo-Chun Hsu
Po-Chun Hsu
YKYa-Chi Ko
Ya-Chi Ko
FCFen-Ling Chen
Fen-Ling Chen
CCChia-Tai Chan
Chia-Tai Chan
The needs for light-weight and soft smart clothing in homecare have been rising since the past decade. Many smart textile sensors have been developed and applied to automatic physiological and user-centered environmental status recognition. In the present study, we propose wearable multi-sensor smart clothing for homecare monitoring based on an economic fabric electrode with high elasticity and low resistance. The wearable smart clothing integrated with heterogeneous sensors is capable to measure multiple human biosignals (ECG and respiration), acceleration, and gyro information. Five independent respiratory signals (electric impedance plethysmography, respiratory induced frequency variation, respiratory induced amplitude variation, respiratory induced intensity variation, and respiratory induced movement variation) are obtained. The smart clothing can provide accurate respiratory rate estimation by using three different techniques (Naïve Bayes inference, static Kalman filter, and dynamic Kalman filter). During the static sitting experiments, respiratory induced frequency variation has the best performance; whereas during the running experiments, respiratory induced amplitude variation has the best performance. The Naïve Bayes inference and dynamic Kalman filter have shown good results. The novel smart clothing is soft, elastic, and washable and it is suitable for long-term monitoring in homecare medical service and healthcare industry.

8 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
KLKai-Chun Liu
Kai-Chun Liu
CHChih-Ning Huang
Chih-Ning Huang
WCWoei-Chyn Chu
Woei-Chyn Chu
CCChia-Tai Chan
Chia-Tai Chan
Falls are the primary cause of accidents for the elderly in the living environment. Reducing hazards in the living environment and performing exercises for training balance and muscles are the common strategies for fall prevention. However, falls cannot be avoided completely; fall detection provides an alarm that can decrease injuries or death caused by the lack of rescue. The automatic fall detection system has opportunities to provide real-time emergency alarms for improving the safety and quality of home healthcare services. Two common technical challenges are also tackled in order to provide a reliable fall detection algorithm, including variability and ambiguity. We propose a novel hierarchical fall detection algorithm involving threshold-based and knowledge-based approaches to detect a fall event. The threshold-based approach efficiently supports the detection and identification of fall events from continuous sensor data. A multiphase fall model is utilized, including free fall, impact, and rest phases for the knowledge-based approach, which identifies fall events and has the potential to deal with the aforementioned technical challenges of a fall detection system. Seven kinds of falls and seven types of daily activities arranged in an experiment are used to explore the performance of the proposed fall detection algorithm. The overall performances of the sensitivity, specificity, precision, and accuracy using a knowledge-based algorithm are 99.79%, 98.74%, 99.05% and 99.33%, respectively. The results show that the proposed novel hierarchical fall detection algorithm can cope with the variability and ambiguity of the technical challenges and fulfill the reliability, adaptability, and flexibility requirements of an automatic fall detection system with respect to the individual differences.

22 November 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KLKai-Chun Liu
Kai-Chun Liu
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
HHHsiang-Yun Huang
Hsiang-Yun Huang
SHSteen Hsu
Steen Hsu
CCChia-Tai Chan
Chia-Tai Chan
Falls are the major risks and threats among elderly population. Various studies have developed automatic critical fall detection systems for emergency alarms and medical services. Window sizes and segmentation approaches would affect the system performance in terms of power consumption, computational speed and reliability that are essential considerations in the real-world implementation. Intuitively, employing shorter window sizes and simpler segmentation approaches leads to a faster detection speed and better power efficiency. However, few works explore the effects of windowing methods on detection performance, especially for machine learning models. This paper investigates the impact of segmentation approaches and window sizes in wearable-based critical fall detection systems with machine learning models. Two generally used segmentation approaches, including sliding windows and impact-defined windows, are explored with a range of window sizes from 0.5 s to 5.0 s and four machine learning models: Support Vector Machine (SVM), k-Nearest Neighbor (k-NN), Classification and Regression Tree (CART) and Naove Bayes (NB). The results show that sliding windows are more sensitive to the changes of window sizes compared to impact-defined windows. However, the differences between the best performance of both segmentation approaches are within 1% (99.66% in sliding windows and 99.78% in impact-defined windows). For systems with SVM and k-NN models, using 0.5 s window sizes in sliding windows and combinations of 1.5 s backward and forward windows in impact-defined windows are sufficient to achieve at least 94% accuracy and 98% accuracy.