Mohd Faris bin Abdullah

Mohd Faris bin Abdullah


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2020 in Clean Technologies
Verified
Journal Article
Open access
PDF file
MKMohamed Atef Khamis
Mohamed Atef Khamis
TKTamer Khatib
Tamer Khatib
MAMohd Faris bin Abdullah
Mohd Faris bin Abdullah
Mohd Fakhizan  RomlieMohd Fakhizan Romlie
Mohd Fakhizan Romlie
In this paper, an optimization approach for designing a hybrid renewable energy system with zero load rejection is presented for a specific location in Malaysia. The proposed renewble energy system includes photovoltaic system, gas turbine generator and battery bank. The aim of the optimization process is to design the system with a loss of load probability that is less than 1%. An improved numerical algorithm is proposed in this paper. Moreover, a comparison between electrification options, including the existing gas-turbine-based generator (existing system), electricity grid and the proposed system, is presented in terms of the annualized total life-cycle cost. The results show that the proposed system can reduce the annual running cost by USD 2.1 million, while the electricity grid connection option can reduce the annual cost by USD 1.16 million as compared to the existing gas-turbine-based generator. In addition to this, the proposed optimization algorithm provides a reliable power system with zero load rejection based on simulation results.

26 September 2019 in Infrastructures
Verified
Journal Article
Open access
PDF file
MUMoslem Uddin
Moslem Uddin
Mohd Fakhizan  RomlieMohd Fakhizan Romlie
Mohd Fakhizan Romlie
MAMohd Faris bin Abdullah
Mohd Faris bin Abdullah
In this study, the performance of an islanded gas turbine power generation system in Malaysia was investigated. Considering the low fuel efficiency of the plant during peak and part-load operations, an economic analysis was also carried out, over the period of one year (2017). The case study was conducted on the isolated electrical network of the Universiti Teknologi PETRONAS (UTP), which consists of two gas turbine units with a total capacity of 8.4 MW. Simple performance indicators were developed to assess the performance, which can also be applied to other power stations in Malaysia and elsewhere. Meanwhile, the economy of variable load operations was analyzed using the statistical data of generation, fuel consumption, and loads. The study reveals that the capacity factor of the microgrid in the period was between 52.77–63.32%, as compared to the industrial best practice of 80%. The average plant use factor for the period under review was 75.04%, with a minimum of 70.93% and a maximum of 78.61%. The load factor of the microgrid ranged from 56.68–65.47%, as compared to the international best practice of 80%, while the utilization factor was between 44.22–67.655%. This study further reveals that high fuel consumption rates, due to the peak and part-load operations, resulted in a revenue loss of approximately 17,379.793 USD per year. Based on the present performance of the microgrid, suggestions are made for the improvement of the overall performance and profitability of the system. This work can be valuable for microgrid utility research to identify the most economical operating conditions.

5 November 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
HRH.A. Rahman
H.A. Rahman
NRN.I. Shah Riman
N.I. Shah Riman
MAMohd Faris bin Abdullah
Mohd Faris bin Abdullah
HSH. Sakidin
H. Sakidin
MRM.F. Romlie
M.F. Romlie
NNN.M. Nor
N.M. Nor
Third harmonic (TH) current from salient-pole synchronous generator that return to its neutral via cable capacitance or other neutral grounding points in the network can cause the neutral earthing resistor (NER) to experience high temperature. Generator neutral earthing reactance (NERX) can be used to mitigate the TH current flowing in the neutral under normal condition. This paper aims to study the suitable design of NERX to be implemented in Universiti Teknologi PETRONAS (UTP) distribution system to reduce the TH current at the generator neutral. The model of UTP distribution system is developed using MATLAB Simulink in order to simulate the flow of TH current. NERX is then designed and implemented to the system to mitigate the magnitude of TH current. Various values of NERX are applied to the system as the neutral current and fault current are recorded and graphed. The application of 0.175 H NERX increased the TH neutral current in island mode and normal operation to 33.18 %. However, the NERX causes the TH fault current to reduce to 44.33 % under fault. For parallel mode, 78.27 % of TH neutral current and also 42.91 % of TH fault current are reduced under normal operation and fault respectively.

9 June 2018
Verified
Book Chapter
Closed access
PDF file
MAMohd Faris bin Abdullah
Mohd Faris bin Abdullah
MAMoustafa Ahmed
Moustafa Ahmed
KHKhairul Nisak Md Hasan
Khairul Nisak Md Hasan