Cardiography is an indispensable element of health care. However, the accessibility of at-home cardiac monitoring is limited by device complexity, accuracy, and cost. We have developed a real-time algorithm for heart rate monitoring and beat detection implemented in a custom-built, affordable system. These measurements were processed from seismocardiography (SCG) and gyrocardiography (GCG) signals recorded at the sternum, with concurrent electrocardiography (ECG) used as a reference. Our system demonstrated the feasibility of non-invasive electro-mechanical cardiac monitoring on supine, stationary subjects at a cost of $100, and with the SCG–GCG and ECG algorithms decoupled as standalone measurements. Testing was performed on 25 subjects in the supine position when relaxed, and when recovering from physical exercise, to record 23,984 cardiac cycles at heart rates in the range of 36–140 bpm. The correlation between the two measurements had r2 coefficients of 0.9783 and 0.9982 for normal (averaged) and instantaneous (beat identification) heart rates, respectively. At a sampling frequency of 250 Hz, the average computational time required was 0.088 s per measurement cycle, indicating the maximum refresh rate. A combined SCG and GCG measurement was found to improve accuracy due to fundamentally different noise rejection criteria in the mutually orthogonal signals. The speed, accuracy, and simplicity of our system validated its potential as a real-time, non-invasive, and affordable solution for outpatient cardiac monitoring in situations with negligible motion artifact.

7 March 2019 in IEEE Sensors Journal
Verified
Journal Article
Open access
YDYannick D'Mello
Yannick D'Mello
JSJames Skoric
James Skoric
SXShicheng Xu
Shicheng Xu
MAMegan Akhras
Megan Akhras
PRPhilip J. R. Roche
Philip J. R. Roche
DPDavid V. Plant
David V. Plant
Objective: We present a novel seismocardiography (SCG) -based approach for real-time cardio-respiratory activity measurement called the Autocorrelated Differential Algorithm (ADA). Methods: Measurements were performed on ten male subjects in the supine position for three 7-minute-long sets each, corresponding to 14,619 heartbeats. The ADA utilized temporal variations, windowing, and autocorrelation to produce physiological measurements corresponding to heart rate (HR), and left ventricular ejection time, and estimations of respiration rate, volume, and phase. The versatility of the ADA was investigated in two contexts: physical exertion and heart rate variability. Results: The accuracy of HR measurements at a sampling frequency of 200 Hz resulted in a correlation coefficient (r 2 ) of 0.9808 when compared with a manual annotation of all datasets. Its reproducibility was tested on externally obtained SCG and electrocardiography datasets, which produced an r 2 of 0.8224. The accuracy and computational time was also characterized for different sampling frequencies to quantify performance. The recommended sampling frequency is 200 Hz corresponding to a computation time of 0.05 s per instantaneous measurement using a standard desktop computer. Conclusion: The ADA delivered real-time SCG measurements with a refresh rate that was dependent on the computational time per measurement, which could be decreased by lowering the sampling frequency. Significance: The presented algorithm offers a novel tool towards real-time physiological monitoring in clinical and everyday scenarios.

15 August 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
MVMadison Vanosdoll
Madison Vanosdoll
NNNatalie Ng
Natalie Ng
AHAnthony Ho
Anthony Ho
AWAllison Wallingford
Allison Wallingford
SXShicheng Xu
Shicheng Xu
SASoumyadipta Acharya
Soumyadipta Acharya
Background: While early identification of neonatal illness can impact neonatal mortality rates and reduce the burden of treatment, identifying subtle clinical signs and symptoms of possible severe illness is especially challenging in neonates. The World Health Organization and the United Nations Children’s Fund developed the Integrated Management of Neonatal Childhood Illness guidelines, an evidence-based tool highlighting seven danger signs to assess neonatal health. Currently, many mothers in low-resource settings rely on home visits from community health workers (CHWs) to determine if their baby is sick. However, CHWs visit infrequently, and illness is often detected too late to impact survival. Thus, delays in illness identification pose a significant barrier to providing expedient and effective care. Neonatal Monitoring (NeMo), a novel neonatal assessment tool, seeks to increase the frequency of neonatal screening by task-shifting identification of neonatal danger signs from CHWs to mothers. Objective: This study aimed to explore the usability and acceptability of the NeMo system among target users and volunteer CHWs by assessing ease of use and learnability. Methods: Simulated device use and semistructured interviews were conducted with 32 women in the Iganga-Mayuge districts in eastern Uganda to evaluate the usability of the NeMo system, which involves a smartphone app paired with a low cost, wearable band to aid in identification of neonatal illness. Two versions of the app were evaluated using a mixed methods approach, and version II of the app contained modifications based on observations of the first cohort’s use of the system. During the posed scenario simulations, participants were offered limited guidance from the study team in order to probe the intuitiveness of the NeMo system. The ability to complete a set of tasks with the system was tested and recorded for each participant and closed- and open-ended questions were used to elicit user feedback. Additionally, focus groups with 12 CHWs were conducted to lend additional context and insight to the usability and feasibility assessment. Results: A total of 13/22 subjects (59%) using app version I and 9/10 subjects (90%) using app version II were able to use the phone and app with no difficulty, despite varying levels of smartphone experience. Following modifications to the app’s audio instructions in version II, participants’ ability to accurately answer qualitative questions concerning neonatal danger signs improved by at least 200% for each qualitative danger sign. All participants agreed they would trust and use the NeMo system to assess the health of their babies. Furthermore, CHWs emphasized the importance of community sensitization towards the system to encourage its adoption and regular use, as well as the decision to seek care based on its recommendations. Conclusions: The NeMo system is an intuitive platform for neonatal assessment in a home setting and was found to be acceptable to women in rural Uganda.

10 February 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
SMShababa B Matin
Shababa B Matin
AWAllison Wallingford
Allison Wallingford
SXShicheng Xu
Shicheng Xu
NNNatalie Ng
Natalie Ng
AHAnthony Ho
Anthony Ho
SASoumyadipta Acharya
Soumyadipta Acharya
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.