Michele Conti

Michele Conti

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2010 in Medical Engineering & Physics
Verified
Journal Article
Closed access
FAFerdinando Auricchio
Ferdinando Auricchio
MCMichele Conti
Michele Conti
MBM. De Beule
M. De Beule
GSG. De Santis
G. De Santis
BVB. Verhegghe
B. Verhegghe
The outcome of carotid artery stenting (CAS) depends on a proper selection of patients and devices, requiring dedicated tools able to relate the device features with the target vessel. In the present study, we use finite element analysis to evaluate the performance of three self-expanding stent designs (laser-cut open-cell, laser-cut closed-cell, braided closed-cell) in a carotid artery (CA). We define six stent models considering the three designs in different sizes and configurations (i.e. straight and tapered), evaluating the stress induced in the vessel wall, the lumen gain and the vessel straightening in a patient-specific CA model based on computed angiography tomography (CTA) images. For the considered vascular anatomy and stents, the results suggest that: (i) the laser-cut closed-cell design provides a higher lumen gain; (ii) the impact of the stent configuration and of the stent oversizing is negligible with respect to the lumen gain and relevant with respect to the stress induced in the vessel wall; (iii) stent design, configuration and size have a limited impact on the vessel straightening. The presented numerical model represents a first step towards a quantitative assessment of the relation between a given carotid stent design and a given patient-specific CA anatomy.

1 August 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
SMS. Morganti
S. Morganti
MCMichele Conti
Michele Conti
MAM. Aiello
M. Aiello
AVA. Valentini
A. Valentini
AMA. Mazzola
A. Mazzola
FAFerdinando Auricchio
Ferdinando Auricchio

21 November 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
FAFerdinando Auricchio
Ferdinando Auricchio
MCMichele Conti
Michele Conti
SMS. Morganti
S. Morganti
Alessandro RealiAlessandro Reali
Alessandro Reali
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy ( − 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall ( − 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.

5 August 2019 in Cells
Verified
Journal Article
Open access
PDF file
VFValentina Fantini
Valentina Fantini
MBMatteo Bordoni
Matteo Bordoni
FSFranca Scocozza
Franca Scocozza
MCMichele Conti
Michele Conti
Eveljn ScarianEveljn Scarian
Eveljn Scarian
CCCristina Cereda
Cristina Cereda
Neurodegenerative diseases (NDs) are a broad class of pathologies characterized by the progressive loss of neurons in the central nervous system. The main problem in the study of NDs is the lack of an adequate realistic experimental model to study the pathogenic mechanisms. Induced pluripotent stem cells (iPSCs) partially overcome the problem, with their capability to differentiate into almost every cell types; even so, these cells alone are not sufficient to unveil the mechanisms underlying NDs. 3D bioprinting allows to control the distribution of cells such as neurons, leading to the creation of a realistic in vitro model. In this work, we analyzed two biomaterials: sodium alginate and gelatin, and three different cell types: a neuroblastoma cell line (SH-SY5Y), iPSCs, and neural stem cells. All cells were encapsulated inside the bioink, printed and cultivated for at least seven days; they all presented good viability. We also evaluated the maintenance of the printed shape, opening the possibility to obtain a reliable in vitro neural tissue combining 3D bioprinting and iPSCs technology, optimizing the study of the degenerative processes that are still widely unknown.

1 May 2013 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
FAFerdinando Auricchio
Ferdinando Auricchio
MCMichele Conti
Michele Conti
SMStefania Marconi
Stefania Marconi
Alessandro RealiAlessandro Reali
Alessandro Reali
JTJip L. Tolenaar
Jip L. Tolenaar
STSanti Trimarchi
Santi Trimarchi

29 June 2017 in International Journal for Numerical Methods in Engineering
Verified
Journal Article
Closed access
PDF file
XZX. Zou
X. Zou
MCMichele Conti
Michele Conti
PDPedro Diez
Pedro Diez
FAF. Auricchio
F. Auricchio