The optional types of power source and actuator in the aircraft are more and more diverse due to fast development in more electric technology, which makes the combinations of different power sources and actuators become extremely complex in the architecture optimization process of airborne actuation system. The traditional “trial and error” method cannot satisfy the design demands. In this paper, firstly, the composition of more electric aircraft (MEA) flight control actuation system (FCAS) is introduced, and the possible architecture quantity is calculated. Secondly, the evaluation criteria of FCAS architecture with respect to safe reliability, weight and efficiency are proposed, and the evaluation criteria values are calculated in the case that each control surface adopts the same actuator configuration. Finally, the optimization results of MEA FCAS architecture are obtained by applying genetic algorithm (GA). Compared to the traditional actuation system architecture, which only adopts servo valve controlled hydraulic actuators, the weight of the optimized more electric actuation system architecture can be reduced by 6%, and the efficiency can be improved by 30% based on the safe reliability requirements
A novel discrete-valued model-predictive control (DVMPC) algorithm termed DVMPC2 for the position control of pneumatic actuators using inexpensive on/off valves is presented. DVMPC2 includes a more flexible cost function, an improved prediction strategy, and other improvements. The actuator is a double-acting cylinder with two on/off solenoid poppet valves connected to each chamber. To reduce the switching frequency and prolong the valve life, DVMPC2 directly switches the valves when necessary, instead of using relatively high-frequency pulse-width modulation. Experimental comparisons are made with the state-of-the-art sliding-mode control (SMC) algorithm and the previous DVMPC algorithm. The comparisons are based on the five performance metrics: integral of time-weighted absolute error (ITAE), root mean square error (RMSE), overshoot (OS), steady-state error (SSE), and valve switches per second (SPS). The robustness is evaluated by increasing and decreasing the total mass of the moving components while keeping the controller parameters constant. The experimental results show that the proposed algorithm is superior to the previous DVMPC and outperformed SMC by a wide margin. Specifically, DVMPC2 reduced ITAE by 80%, RMSE by 52%, OS by 43%, and SPS by 20% relative to SMC. There was no clear winner in terms of SSE.
The electro-hydrostatic actuator (EHA) is the key component of most electric aircraft, and research on its fault diagnosis technology is of great significance to improve the safety and reliability of aircraft flight. However, traditional fault diagnosis methods only focus on partial failures and cannot completely diagnose the whole EHA system. In this paper, the progressive fault diagnosis method (PFDM) is proposed for overall diagnosis of whole EHA system, which can be divided into four levels for health detection and fault diagnosis of the overall EHA system. PFDM combines fault diagnosis methods based on Kalman filter, threshold, logic, and EHA system analysis model to diagnose the whole EHA system layer by layer. At the same time, in order to ensure the normal operation of the EHA system after fault diagnosis, double redundancy design is creatively carried out for the EHA system to facilitate system reconstruction after fault detection. It can be continuously modified according to different EHA system parameters and measured signals to improve the accuracy of fault diagnosis. The experimental results show that PFDM can accurately locate and identify 22 faults of the double redundancy EHA system by using the accurate EHA system mathematical model. PFDM improves the fault diagnosis response time to 4 ms, greatly improving the safety and reliability of the double redundancy EHA system.
Compared with the general ball screw electromechanical actuators (EMAs), direct drive EMAs have several attractive advantages such as more reliable, efficient, accurate, and integrated due to the elimination of the intermediate gear boxes. However, the direct drive structure brings challenges to the servo control of the permanent magnetic synchronous motors (PMSMs) which are widely used in EMAs. Aiming at improving the performance of the PMSM servo system, such as wide speed range and outstanding load disturbance-rejection ability, a novel active disturbance rejection control (ADRC) is presented in this paper. To begin with, as a technique for estimating and compensating uncertainties, characteristics, and principles of the ADRC strategy are introduced in detail by comparing with PID and several advanced control strategies. Then, based on the PMSM model in d-q frame, an ADRC controller for the d-axis current is designed to implement the rotor flux linkage oriented vector control. Finally, ADRC controllers for the position and q-axis current are designed to complete the position servo control. Simulation results verify that the ADRC-based PMSM servo system is fast, precise, of no overshoot and strongly robust to load disturbance. Therefore, the ADRC strategy is feasible in the PMSM servo control and this provides necessary technical support to the direct drive EMA, which is one of the enabling technologies for the all-electric aircraft (AEA).
17 January 2018 in Mathematical Problems in Engineering
A novel sliding mode control (SMC) design framework is devoted to providing a favorable SMC design solution for the position tracking control of electrohydrostatic actuation system (EHSAS). This framework is composed of three submodules as follows: a reduced-order model of EHSAS, a disturbance sliding mode observer (DSMO), and a new adaptive reaching law (NARL). First, a reduced-order model is obtained by analyzing the flow rate continuation equation of EHSAS to avoid the use of a state observer. Second, DSMO is proposed to estimate and compensate mismatched disturbances existing in the reduced-order model. In addition, a NARL is developed to tackle the inherent chattering problem of SMC. Extensive simulations are conducted compared with the wide adoption of three-loop PID method on the cosimulation platform of EHSAS, which is built by combining AMESim with MATLAB/Simulink, to verify the feasibility and superiority of the proposed scheme. Results demonstrate that the chattering can be effectively attenuated, and the mismatched disturbance can be satisfyingly compensated. Moreover, the transient performance, steady-state accuracy, and robustness of position control are all improved.
Aiming at the problem that different sections of the flight profile have different requirements on dynamic response and energy loss, by adjusting the rotating speed in steady state and the matrix R to make the system meet the requirement is put forward. The EHA-VPVM is modeled and simulated in the Matlab/Simulink and AMESim software. The simulation results show that the dynamic response and energy loss of system are determined by rotating speed in steady-state and the weighting coefficients of the displacement and the rotating speed of pump in the matrix R. The dynamic response becomes faster as the steady-state rotating speed increases, but the energy loss becomes more. It would improve the dynamic response when reducing the weighting coefficient of displacement in matrix R appropriately.