Karina Klein

Dr. Karina Klein

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2012 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
MPMichael Plecko
Michael Plecko
CSChristine Sievert
Christine Sievert
DADaniel Andermatt
Daniel Andermatt
RFRobert Frigg
Robert Frigg
PKPeter WM Kronen
Peter WM Kronen
BRBrigitte von Rechenberg
Brigitte von Rechenberg
Background: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.Methods: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.Results: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.Conclusion: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.

1 February 2015 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
HRHenning Richter
Henning Richter
MPMichael Plecko
Michael Plecko
DADaniel Andermatt
Daniel Andermatt
RFRobert Frigg
Robert Frigg
PKPeter WM Kronen
Peter WM Kronen
BRBrigitte von Rechenberg
Brigitte von Rechenberg
Ffect on bone-healing of dynamization of locking plate constructs by means of new 5.0-mm dynamic locking screws (in the DLS group), which allow near-cortex micromotion, compared with a more rigid construct utilizing standard bicortical locking-head screws (in the LS group). Use of dynamic locking screws allows modulation of the stiffness of existing locking compression plate systems via parallel interfragmentary micromotion. Methods: A standardized diaphyseal tibial osteotomy (90°, 3-mm fracture gap) was performed and stabilized with a six-hole large-fragment locking compression plate in twelve female sheep (six in each group). Radiographs were made postoperatively and then weekly from week three until sacrifice at nine weeks. Macroscopic, biomechanical, histologic, and radiographic assessments and microcomputed tomography were performed. Results: The callus in the tested specimens in the DLS group had better biomechanical stability, with a significantly greater maximum failure moment (mean and standard deviation [SD] as a percentage of intact, 55.15 ± 20.65 compared with 26.80 ± 14.96 in the LS group; p = 0.021). The DLS group also had greater periosteal callus volume at the near cortex (mean volume and SD as a percentage of the tibial shaft volume, 36.21% ± 10.08% compared with 18.98% ± 8.61% in the LS group; p = 0.026) and in the intercortical region (mean volume and SD as a percentage of the bone volume of the tibial shaft, 3.56% ± 0.52% compared with 2.64% ± 0.98% in the LS group; p = 0.045), as shown by microcomputed tomography. The DLS group also had significantly greater torsional stiffness (mean and SD as a percentage of intact, 84.88 ± 13.51 compared with 58.89 ± 20.61 in the LS group; p = 0.027). Conclusions: Controlled micromotion and nearly homogeneous interfragmentary strain at the fracture site, together with the stable bicortical fixation achieved by the new dynamic locking screw, led to more uniform callus formation, significantly more callus formation at the near cortex, and biomechanically more competent bone-healing compared with use of rigid locking plate constructs with locking-head screws....

1 October 2013 in Injury
Verified
Journal Article
Closed access
MPMichael Plecko
Michael Plecko
NLNico Lagerpusch
Nico Lagerpusch
DADaniel Andermatt
Daniel Andermatt
RFRobert Frigg
Robert Frigg
RKRudolf Koch
Rudolf Koch
BRBrigitte von Rechenberg
Brigitte von Rechenberg

1 January 2025 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
MTMaham Tanveer
Maham Tanveer
KKKarina Klein
Karina Klein
BRBrigitte von Rechenberg
Brigitte von Rechenberg
SDSalim Darwiche
Salim Darwiche
HDHannah L. Dailey
Hannah L. Dailey
Aims: The “2 to 10% strain rule” for fracture healing has been widely interpreted to mean that interfragmentary strain greater than 10% predisposes a fracture to nonunion. This interpretation focuses on the gap-closing strain (axial micromotion divided by gap size), ignoring the region around the gap where osteogenesis typically initiates. The aim of this study was to measure gap-closing and 3D interfragmentary strains in plated ovine osteotomies and associate local strain conditions with callus mineralization.Methods: MicroCT scans of eight female sheep with plated mid-shaft tibial osteotomies were used to create image-based finite element models. Virtual mechanical testing was used to compute postoperative gap-closing and 3D continuum strains representing compression (volumetric strain) and shear deformation (distortional strain). Callus mineralization was measured in zones in and around the osteotomy gap.Results: Gap-closing strains averaged 51% (mean) at the far cortex. Peak compressive volumetric strain averaged 32% and only a small tissue volume (average 0.3 cm3) within the gap experienced compressive strains > 10%. Distortional strains were much higher and more widespread, peaking at a mean of 115%, with a mean of 3.3 cm3 of tissue in and around the osteotomy experiencing distortional strains > 10%. Callus mineralization initiated outside the high-strain gap and was significantly lower within the fracture gap compared to around it at nine weeks.Conclusion: Ovine osteotomies can heal with high gap strains (> 10%) dominated by shear conditions. High gap strain appears to be a transient local limiter of osteogenesis, not a global inhibitor of secondary fracture repair.Cite this article: Bone Joint Res 2025;14(1):5–15.

2 July 2013 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
KKKarina Klein
Karina Klein
EZEnrico Zamparo
Enrico Zamparo
PKPeter WM Kronen
Peter WM Kronen
KKKatharina Kämpf
Katharina Kämpf
MMMariano Makara
Mariano Makara
BRBrigitte von Rechenberg
Brigitte von Rechenberg
Reproducible and suitable animal models are required for in vivo experiments to investigate new biodegradable and osteoinductive biomaterials for augmentation of bones at risk for osteoporotic fractures. Sheep have especially been used as a model for the human spine due to their size and similar bone metabolism. However, although sheep and human vertebral bodies have similar biomechanical characteristics, the shape of the vertebral bodies, the size of the transverse processes, and the different orientation of the facet joints of sheep are quite different from those of humans making the surgical approach complicated and unpredictable. Therefore, an adequate and safe animal model for bone augmentation was developed using a standardized femoral and tibia augmentation site in sheep. The cancellous bone of the distal femur and proximal tibia were chosen as injection sites with the surgical approach via the medial aspects of the femoral condyle and proximal tibia metaphysis (n = 4 injection sites). For reproducible drilling and injection in a given direction and length, a custom-made c-shaped aiming device was designed. Exact positioning of the aiming device and needle positioning within the intertrabecular space of the intact bone could be validated in a predictable and standardized fashion using fluoroscopy. After sacrifice, bone cylinders (∅ 32 mm) were harvested throughout the tibia and femur by means of a diamond-coated core drill, which was especially developed to harvest the injected bone area exactly. Thereafter, the extracted bone cylinders were processed as non-decalcified specimens for μCT analysis, histomorphometry, histology, and fluorescence evaluation. The aiming device could be easily placed in 63 sheep and assured a reproducible, standardized injection area. In four sheep, cardiovascular complications occurred during surgery and pulmonary embolism was detected by computed tomography post surgery in all of these animals. The harvesting and evaluative methods assured a standardized analysis of all samples. This experimental animal model provides an excellent basis for testing new biomaterials for their suitability as bone augmentation materials. Concomitantly, similar cardiovascular changes occur during vertebroplasties as in humans, thus making it a suitable animal model for studies related to vertebroplasty.

25 June 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SSSarah Schleich
Sarah Schleich
PKPeter Kronen
Peter Kronen
AKAdva Krivitsky
Adva Krivitsky
NPNevena Paunović
Nevena Paunović
CBCoulter Fergal Brian
Coulter Fergal Brian
KKKarina Klein
Karina Klein
To date, several types of airway stents are available to treat central airway obstructions. However, the ideal stent that can overcome anatomical, mechanical and microbiological issues is still awaited. In addition, therapeutic effect and self-elimination of these stents are desirable properties, which pose an additional challenge for development and manufacturing. We aimed to create a prototype bioresorbable tracheal stent with acceptable clinical tolerance, fit and biocompatibility, that could be tested in a rabbit model and in the future be further optimized to enable drug-elution and ensure local therapeutic effect. Twenty-one New Zealand White Rabbits received five different types of bioresorbable tracheal stents, 3D-printed from poly(D,L-lactide-co-ε-caprolactone) metacrylates. Various configurations were tested for their functionality and improved until the best performing prototype could undergo detailed in vivo assessment, regarding clinical tolerance, migration and biocompatibility. Previously tested types of 3D printed stents in our preliminary study required improvement due to several problems, mainly related to breakage, unreliable stability and/or migration within the trachea. Abandoned or refined pre-prototypes were not analyzed in a comparative way. The final best performing prototype stent (GSP2 (Group Stent Prototype 2), n = 8) allowed a transoral application mode and showed good clinical tolerance, minimal migration and acceptable biocompatibility. The good performance of stent type GSP2 was attributed to the helix-shaped surface structure, which was therefore regarded as a key-feature. This prototype stent offers the possibility for further research in a large animal model to confirm the promising data and assess other properties such as bioresorption.