The design of stationary and single axes tracking collectors in a field consisting of rows of collectors involves relationships between the field and collector parameters and solar radiation data. In addition, shading and masking of adjacent rows affect the collector deployment of the field by decreasing the incident energy on the collector plane. The use of many rows, densely deployed in a given field, increases the field incident energy but also increases the shading. Therefore, there is an optimal deployment of the collectors in the field yielding, for example, maximum energy, minimum required field area, or other objectives. For photovoltaic collectors, the output energy depends on the module efficiency, the solar cell operating temperature, and on the scheme of the electrically interconnected modules. Series interconnection between the photovoltaic modules may have a significant effect on the output energy of the solar plant in event of shading. The present article deals with the optimal design of photovoltaic solar fields for stationary and single axes tracking collectors to obtain maximum annual output energy.
The operating temperature of photovoltaic (PV) modules affects the photovoltaic conversion process. The operating temperature depends on various environmental conditions and on material-dependent properties of the PV modules. Many expressions for the operating temperature have been proposed in the literatures, some are simplified working Equation as NOCT (Nominal Operating Cell Temperature), and others are more complex, being based on a combination of the energy balance Equation and NOCT. The present study offers a new approach (model) for determining the PV module temperature based on the energy balance Equation and on the solar spectrum irradiance. While using the new model, the operating temperature has been determined for four module technologies: c-Si, a-Si/ c-Si, CdTe, and CIGS and it shows that the operating temperatures for the different cell types are close to the manufacturers’ NOCT data-sheet temperatures. For c-Si technology, for example, the simulation resulted in 43.2° and 46° for the spectrum and NOCT models, respectively. The proposed new model offers a new approach for determining the operating temperature of PV modules.
1 March 2016 in Journal of Renewable and Sustainable Energy
The diffuse radiation is an important component of the global radiation affecting the output of photovoltaic (PV) collectors. This radiation depends on the view factor between the collector and sky. A simple expression for the view factor for single inclined collectors on a horizontal plane is known. However, for a photovoltaic solar field with multiple rows deployed on a horizontal or on inclined planes, the view factor is more complicated to calculate, because a collector row may obscure part of the sky for the adjacent row. More complication is added for collectors deployed on saw-tooth roofs. The present study deals with the calculation of view factors to sky for collectors deployed in multiple rows and in the presence of obscuring structures on roof tops. General and particular mathematical expressions for view factors to sky were developed for PV collectors deployed on grounds or on roof tops to determine the diffuse incident solar radiation on PV collectors, and numerical values of view factors were presented. The view factor to sky depends significantly on the inclination angle of the collector. For common deployment of collectors in multiple rows on horizontal planes, the view to sky is in the range between 0.8 and 0.9 for 30° inclination angle, whereas for 50° inclination angle, the range is between 0.6 and 0.7. The effect of the distance between collectors on the view factor is less pronounced. A wall or a fence in front of the collector may decrease significantly the view factor to sky; an increase of 1.0 to 3.0 m decreases the view to sky from 0.8 to 0.6 for 30° inclination, and from 0.7 to 0.4 for 50° inclination. The view factor to sky of vertical collectors is less than 0.5.
2 September 2016 in Journal of Solar Energy Engineering
Ground reflected radiation is one component of the global radiation on photovoltaic collectors in a solar field. This component depends on the view factor of the collector to ground, hence depends on the relative position of the collectors to each other. General analytical expressions and numerical values for the view factor to the ground were developed between flat-plate collectors positioned in a general configuration. Based on the general expression, the view factors to ground for particular collector configurations were derived. For deployment of photovoltaic collectors in multiple rows with common inclination angles, the view factor to ground is rather small, and hence, the reflected radiation from the ground on the collectors may be neglected compared to the direct beam and the diffuse components. However, in some cases the reflected radiation from the ground may constitute an appreciable amount as in snowy area. Bifacial photovoltaic (PV) panels can absorb solar radiation by both the front and the rear sides and are usually deployed vertically. In this case the reflected radiation from the ground on the panels may be appreciable depending on the ground albedo. The mathematical expressions of the different view factors may be used by the solar field designer to estimate the amount of reflected radiation from the ground reaching the collectors for different configurations of solar PV plants.
28 April 2007 in Journal of Solar Energy Engineering
The optimization of solar field designs of stationary thermal collectors, taking into account shading and masking effects, may be based on energy or economic criteria. Obtaining maximum energy from a given field size or determining the required minimum field area that produces a given amount of energy are examples of energy criteria. Designing a solar plant with a minimum cost or a plant that produces minimum cost of unit energy are examples of economic criteria. These design problems may be formulated as optimization problems with objective functions and sets of constraints (equality and inequality) for which mathematical optimization techniques may be applied. This paper deals with obtaining optimal field and collector design parameters (number of rows, distance between collector rows, collector height, and collector inclination angle) that result in minimum periodic cost of a solar plant producing a given amount of annual energy. A second problem is the determination of optimal field and collector design parameters resulting in minimum cost of unit energy for the solar plant. In both cases, the optimal deployment of the collectors in the solar field as a function of the daily energy demand—cost of land and collector efficiency as parameters—is presented.