For over a century there have been many studies that describe the use of rain drop measurement techniques. Initial manual measurement methods evolved due to improved technology to include photographic and, more recently, automated disdrometer and laser measurement techniques. Despite these numerous studies, there have been few comparative reviews of the range of methodologies, and their relative performance. This review explores the raindrop measurement techniques available, and summarizes and classifies the techniques according to the method or principle involved. The requirements of a robust raindrop measurement technique are suggested, and these are reviewed against existing rain drop measurement techniques to provide a comparative guide to the use of the range of techniques available for any research study. This review revealed that while advances in technology have allowed many of the deficiencies of early techniques to be eliminated, challenges remain in relation to the precision of the measurement of the size, shape, and velocity of rain drops.
Increased plant biomass is observed in terrestrial systems due to rising levels of atmospheric CO2, but responses of marine macroalgae to CO2 enrichment are unclear. The 200% increase in CO2 by 2100 is predicted to enhance the productivity of fleshy macroalgae that acquire inorganic carbon solely as CO2 (non‐carbon dioxide‐concentrating mechanism [CCM] species—i.e., species without a carbon dioxide‐concentrating mechanism), whereas those that additionally uptake bicarbonate (CCM species) are predicted to respond neutrally or positively depending on their affinity for bicarbonate. Previous studies, however, show that fleshy macroalgae exhibit a broad variety of responses to CO2 enrichment and the underlying mechanisms are largely unknown. This physiological study compared the responses of a CCM species (Lomentaria australis) with a non‐CCM species (Craspedocarpus ramentaceus) to CO2 enrichment with regards to growth, net photosynthesis, and biochemistry. Contrary to expectations, there was no enrichment effect for the non‐CCM species, whereas the CCM species had a twofold greater growth rate, likely driven by a downregulation of the energetically costly CCM(s). This saved energy was invested into new growth rather than storage lipids and fatty acids. In addition, we conducted a comprehensive literature synthesis to examine the extent to which the growth and photosynthetic responses of fleshy macroalgae to elevated CO2 are related to their carbon acquisition strategies. Findings highlight that the responses of macroalgae to CO2 enrichment cannot be inferred solely from their carbon uptake strategy, and targeted physiological experiments on a wider range of species are needed to better predict responses of macroalgae to future oceanic change.
Floating Treatment Wetland (FTW) systems are purpose-built devices designed to replicate the water treatment processes that occur in and around naturally occurring floating vegetated islands. FTWs can be used to improve the water quality of water storage ponds by contributing to water treatment processes through adhesion, filtration, nutrient uptake (direct use by plants), and sequestration. This paper presents the results of a twelve-month investigation into the pollution removal performance of a FTW receiving stormwater runoff from a 7.46 ha urban residential catchment. As anticipated, there was a high degree of variation in FTW treatment performance between individual rainfall events. Overall pollution removal performance was calculated to be 80% for Total Suspended Solids (TSS), 53% for Total Phosphorous (TP), and 17% for Total Nitrogen (TN) for a FTW footprint of 0.14% of the contributing catchment. TSS and TP concentrations were found to be significantly reduced after FTW treatment. The minimum FTW footprint to catchment size ratio required to achieve regulated nutrient removal rates was calculated to be 0.37%. Sum of loads calculations based on flow resulted in pollution load reductions of TSS 76%, TP 55%, and TN 17%. Pollution treatment performance (particularly for TN) was found to be affected by low influent concentrations, and highly-variable inflow concentrations. The study demonstrated that FTWs are an effective treatment solution for the removal of pollution from urban stormwater runoff.
Adequate infiltration through Permeable Interlocking Concrete Pavements (PICPs) is critical to their hydraulic performance. Detected by monitoring infiltration performance, reduced infiltration rates can indicate that maintenance is required. Measurement of infiltration rates has previously been problematic on PICPs because of a lack of accepted standard methodologies and the practical difficulties in modifying existing testing methodologies. On large sites, standard methodologies necessitate multiple measurements to achieve accuracy. Standard methods also contend with practical issues such as sealing the rings to the surface to prevent lateral water flow. This study examined the performance of two PICP surface infiltration rate measurement methods: a modified double-ring infiltrometer (DRIT), and a specially designed rainfall simulation infiltrometer (RSIT). A positive correlation (R2 = 0.85) of results was found between the two, demonstrating that the RSIT was comparable to the DRIT. The modified DRIT produced surface infiltration results approximately 60% higher than the RSIT results. The RSIT provided lower variation between tests, requiring fewer measurements in large sites whilst still maintaining accuracy, thereby improving testing efficiency. The new RSIT method also eliminates some of the practical difficulties with existing methodologies such as unrealistic pressure heads artificially increasing infiltration rates, and the use of sealant under test measurement infiltration rings.