Liangjing Yang

Dr. Liangjing Yang

1. ZJU-UIUC Institute, Zhejiang University, 718 East Haizhou Road, Haining 314400, China
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JWJunchen Wang
Junchen Wang
HSHideyuki Suenaga
Hideyuki Suenaga
KHKazuto Hoshi
Kazuto Hoshi
LYLiangjing Yang
Liangjing Yang
EKEtsuko Kobayashi
Etsuko Kobayashi
Hongen LiaoHongen Liao
Hongen Liao
Computer-assisted oral and maxillofacial surgery (OMS) has been rapidly evolving since the last decade. State-of-the-art surgical navigation in OMS still suffers from bulky tracking sensors, troublesome image registration procedures, patient movement, loss of depth perception in visual guidance, and low navigation accuracy. We present an augmented reality navigation system with automatic marker-free image registration using 3-D image overlay and stereo tracking for dental surgery. A customized stereo camera is designed to track both the patient and instrument. Image registration is performed by patient tracking and real-time 3-D contour matching, without requiring any fiducial and reference markers. Real-time autostereoscopic 3-D imaging is implemented with the help of a consumer-level graphics processing unit. The resulting 3-D image of the patient's anatomy is overlaid on the surgical site by a half-silvered mirror using image registration and IP-camera registration to guide the surgeon by exposing hidden critical structures. The 3-D image of the surgical instrument is also overlaid over the real one for an augmented display. The 3-D images present both stereo and motion parallax from which depth perception can be obtained. Experiments were performed to evaluate various aspects of the system; the overall image overlay error of the proposed system was 0.71 mm.

26 October 2024
Verified
Book Chapter
Closed access
PDF file
JHJiarui Hu
Jiarui Hu
XCXianhao Chen
Xianhao Chen
BFBoyin Feng
Boyin Feng
GLGuanglin Li
Guanglin Li
LYLiangjing Yang
Liangjing Yang
ZCZhaopeng Cui
Zhaopeng Cui

9 June 2016 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
JWJunchen Wang
Junchen Wang
HSHideyuki Suenaga
Hideyuki Suenaga
LYLiangjing Yang
Liangjing Yang
EKEtsuko Kobayashi
Etsuko Kobayashi
ISIchiro Sakuma
Ichiro Sakuma

1 March 2015 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
JWJunchen Wang
Junchen Wang
HSHideyuki Suenaga
Hideyuki Suenaga
Hongen LiaoHongen Liao
Hongen Liao
KHKazuto Hoshi
Kazuto Hoshi
LYLiangjing Yang
Liangjing Yang
ISIchiro Sakuma
Ichiro Sakuma

7 March 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HLHsieh-Yu Li
Hsieh-Yu Li
IPIshara Paranawithana
Ishara Paranawithana
LYLiangjing Yang
Liangjing Yang
TLTerence Sey Kiat Lim
Terence Sey Kiat Lim
Shaohui FoongShaohui Foong
Shaohui Foong
UTU-Xuan Tan
U-Xuan Tan
There are an increasing number of applications that require the end-effector of a robotic manipulator to be compliant in response to the intended force exerted by a human operator. In physical human-robot interaction, the stability and compliance are often affected in the presence of both human and an environment, especially during the transition from noncontact to contact. Unlike previous works, the physical human-robot interaction in this letter takes into consideration of the interaction of the human, robot, and a moving environment. To achieve this, this letter proposes a variable admittance control strategy with an adaptive controller to produce a time-varying stiffness interacting with the human and a moving environment simultaneously. The passivity of the system is guaranteed for time-varying admittance with human interaction coupled with a moving environment. Experiments are conducted to demonstrate the capability of the controller.

1 December 2010 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
LYLiangjing Yang
Liangjing Yang
RWRong Wen
Rong Wen
Jing QinJing Qin
Jing Qin
CCChee-Kong Chui
Chee-Kong Chui
KLKah-Bin Lim
Kah-Bin Lim
SCStephen Kin-Yong Chang
Stephen Kin-Yong Chang
Overlapping radiofrequency ablation (RFA) in large tumor treatment requires multiple insertions of electrodes, which often compromise its efficacy and predictability. Surgical robot is a promising candidate for the execution of multiple RFA in large tumor treatment in terms of accuracy and speed. In this paper, we share our experience of design and implementation of a novel robotic system specialized for overlapping RFA. It consists of two components: a robotic manipulator and an automatic ablation planning module. The manipulator architecture is designed to facilitate the kinematic requirement for the multiple overlapping ablation technique within the constraints of minimally invasive surgery. An efficient “Voxel Growing” algorithm is adopted to automatically produce the ablation points according to the tumor's profile. The feasibility of the proposed robotic system is demonstrated by extensive simulation- and experiment-based evaluation conducted on ex vivo porcine liver.