This paper presents an experimental study on the behaviour of the bond stress of steel reinforcing bars embedded in steel-fibre-reinforced concrete. In total, 27 specimens were subjected to pull-out tests. The main variables included the volumetric fraction of the fibre, the diameter of the reinforcing bars and the anchorage length. The results showed that the introduction of steel fibres had a significant effect on improving the bond stress performance in terms of the failure load resistance, the tensile resistance of the concrete and the reduction in the anchorage length, resulting in a more ductile bonding behaviour of reinforcing bars with smaller tested diameters. An equation to estimate the ultimate bond stress was proposed based on the prescriptions of the Brazilian design code NBR 6118, which is more accurate and considers the observed effects of the fibre addition.
This experimental investigation presents results and a discussion on a series of four reinforced concrete pile caps with and without steel fibers, measuring 400 × 400 × 1000 mm3, which were tested under concentric loading. The study set the steel fiber and the inclined shear reinforcement as variables. The fiber volume fraction was 1.5%, and the concrete compressive strength was 25 MPa. The results showed a tendency to increase ductility and ultimate strength with the use of inclined shear reinforcement; the same behavior was observed with the addition of steel fibers, improving the performance of the tested pile caps. This study opens the possibility of designing slender pile caps, especially when associated with both analyzed parameters.
1 November 2021 in Practice Periodical on Structural Design and Construction
This study proposes a practical solution for installing anchoring elements on hard or old concrete surfaces to receive tensile forces. For this situation, where the anchorages will be postinstalled, there is often no depth in the concrete base that meets the minimum straight length of standard anchoring. Thus, the use of headed studs or hooked anchor bolts are the most recommended solutions, but the procedure for installing these elements is still the subject of experimental investigations. Then, the technique of postinstallation of headed studs in hardened concrete niches and the use of structural epoxy resin in the new-old concrete interface is presented. Additionally, the influence of the addition of steel fiber on the anchorage studs performance was also evaluated.
1 January 2022 in Revista IBRACON de Estruturas e Materiais
Some normative recommendations are conservative in relation to the shear strength of reinforced concrete beams, not directly considering the longitudinal reinforcement rate. An experimental program containing 8 beams of (100 x 250) mm2 and a length of 1,200 mm was carried out. The concrete compression strength was 20 MPa with and without 1.00% of steel fiber addition, without stirrups and varying the longitudinal reinforcement ratio. Comparisons between experimental failure loads and main design codes estimates were assessed. The results showed that the increase of the longitudinal reinforcement ratio from 0.87% to 2.14% in beams without steel fiber led to an improvement of 59% in shear strength caused by the dowel effect, while the corresponding improvement was of only 22% in fibered concrete beams. A maximum gain of 109% in shear strength was observed with the addition of 1% of steel fibers comparing beams with the same longitudinal reinforcement ratio (1.2%). A significant amount of shear strength was provided by the inclusion of the steel fibers and allowed controlling the propagation of cracks by the effect of stress transfer bridges, transforming the brittle shear mechanism into a ductile flexural one. From this, it is clear the shear benefit of the steel fiber addition when associated to the longitudinal reinforcement and optimal values for this relationship would improve results.
The characterization of steel fiber concrete in a flexural test or tensile uniaxial test requires greater control of loading rate by the speed applied in the test machine, to be able to report more accurately the behavior of displacements or crack openings in micro‐scale possible. In general, in the pre‐dimensioning process, it is often discarded the characterization tests and the main standards do not provide theoretical design recommendations concerning the residual strengths of fibrous concrete. Some empirical models in the literature attempt an approximation of the theoretical design values, but they present greater dispersion in the results. This article proposes empirical equations for predicting the residual strengths of the steel fiber reinforced concrete (SFRC), for small fiber volume fractions (approx. < 0.8%). Experimentally notched beams subjected to three‐point bending tests were collected, with the concrete matrix composed of hook‐end steel fiber and the experimental residual strengths presenting the softening behavior in the load‐opening ratio curve of the crack. The experimental residual strengths were compared with other empirical models found in the literature. The results showed that the maximum stress of the steel fiber pullout model established satisfactory relationships with the residual stresses in flexure. The empirical proposed residual strength model presented lower variability of dispersion around 10%, the mean absolute percentage error of 8%, compared to other usual empirical models and had the same material class with the experimental results, proving to be a viable alternative for pre‐design and dosage optimization for SFRC.