Tao Xu

Dr. Tao Xu

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2011 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TATakahiro Ando
Takahiro Ando
WXWeijun Xuan
Weijun Xuan
TXTao Xu
Tao Xu
TDTianhong Dai
Tianhong Dai
SSSulbha K. Sharma
Sulbha K. Sharma
Michael R. HamblinMichael R. Hamblin
Michael R. Hamblin
Transcranial low-level laser therapy (LLLT) using near-infrared light can efficiently penetrate through the scalp and skull and could allow non-invasive treatment for traumatic brain injury (TBI). In the present study, we compared the therapeutic effect using 810-nm wavelength laser light in continuous and pulsed wave modes in a mouse model of TBI. TBI was induced by a controlled cortical-impact device and 4-hours post-TBI 1-group received a sham treatment and 3-groups received a single exposure to transcranial LLLT, either continuous wave or pulsed at 10-Hz or 100-Hz with a 50% duty cycle. An 810-nm Ga-Al-As diode laser delivered a spot with diameter of 1-cm onto the injured head with a power density of 50-mW/cm2 for 12-minutes giving a fluence of 36-J/cm2. Neurological severity score (NSS) and body weight were measured up to 4 weeks. Mice were sacrificed at 2, 15 and 28 days post-TBI and the lesion size was histologically analyzed. The quantity of ATP production in the brain tissue was determined immediately after laser irradiation. We examined the role of LLLT on the psychological state of the mice at 1 day and 4 weeks after TBI using tail suspension test and forced swim test. The 810-nm laser pulsed at 10-Hz was the most effective judged by improvement in NSS and body weight although the other laser regimens were also effective. The brain lesion volume of mice treated with 10-Hz pulsed-laser irradiation was significantly lower than control group at 15-days and 4-weeks post-TBI. Moreover, we found an antidepressant effect of LLLT at 4-weeks as shown by forced swim and tail suspension tests. The therapeutic effect of LLLT for TBI with an 810-nm laser was more effective at 10-Hz pulse frequency than at CW and 100-Hz. This finding may provide a new insight into biological mechanisms of LLLT.

24 January 2012 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
QWQiuhe Wu
Qiuhe Wu
WXWeijun Xuan
Weijun Xuan
TATakahiro Ando
Takahiro Ando
TXTao Xu
Tao Xu
LHLiyi Huang
Liyi Huang
Michael R. HamblinMichael R. Hamblin
Michael R. Hamblin

7 January 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WXWeijun Xuan
Weijun Xuan
FVFatma Vatansever
Fatma Vatansever
LHLiyi Huang
Liyi Huang
QWQiuhe Wu
Qiuhe Wu
YXYi Xuan
Yi Xuan
Michael R. HamblinMichael R. Hamblin
Michael R. Hamblin
Low-level laser (light) therapy (LLLT) has been clinically applied around the world for a spectrum of disorders requiring healing, regeneration and prevention of tissue death. One area that is attracting growing interest in this scope is the use of transcranial LLLT to treat stroke and traumatic brain injury (TBI). We developed a mouse model of severe TBI induced by controlled cortical impact and explored the effect of different treatment schedules. Adult male BALB/c mice were divided into 3 broad groups (a) sham-TBI sham-treatment, (b) real-TBI sham-treatment, and (c) real-TBI active-treatment. Mice received active-treatment (transcranial LLLT by continuous wave 810 nm laser, 25 mW/cm2, 18 J/cm2, spot diameter 1 cm) while sham-treatment was immobilization only, delivered either as a single treatment at 4 hours post TBI, as 3 daily treatments commencing at 4 hours post TBI or as 14 daily treatments. Mice were sacrificed at 0, 4, 7, 14 and 28 days post-TBI for histology or histomorphometry, and injected with bromodeoxyuridine (BrdU) at days 21–27 to allow identification of proliferating cells. Mice with severe TBI treated with 1-laser Tx (and to a greater extent 3-laser Tx) had significant improvements in neurological severity score (NSS), and wire-grip and motion test (WGMT). However 14-laser Tx provided no benefit over TBI-sham control. Mice receiving 1- and 3-laser Tx had smaller lesion size at 28-days (although the size increased over 4 weeks in all TBI-groups) and less Fluoro-Jade staining for degenerating neurons (at 14 days) than in TBI control and 14-laser Tx groups. There were more BrdU-positive cells in the lesion in 1- and 3-laser groups suggesting LLLT may increase neurogenesis. Transcranial NIR laser may provide benefit in cases of acute TBI provided the optimum treatment regimen is employed.

13 March 2023 in Neuron
Verified
Journal Article
Closed access
XZXiao-Na Zhu
Xiao-Na Zhu
JLJie Li
Jie Li
GQGao-Lin Qiu
Gao-Lin Qiu
LWLin Wang
Lin Wang
CLChen Lu
Chen Lu
Ji HuJi Hu
Ji Hu

1 March 2021 in Pharmacological Research
Verified
Journal Article
Closed access
HWHaiyan Wang
Haiyan Wang
MHMin Huang
Min Huang
WWWenying Wang
Wenying Wang
YZYu Zhang
Yu Zhang
XMXiaqing Ma
Xiaqing Ma
TXTao Xu
Tao Xu

9 January 2020 in Molecular Diagnosis & Therapy
Verified
Journal Article
Closed access
PDF file
DCDake Chen
Dake Chen
TXTao Xu
Tao Xu
SWShubin Wang
Shubin Wang
HCHoward Chang
Howard Chang
TYTao Yu
Tao Yu
JCJian Chen
Jian Chen