Duc-Tan Tran

Prof. Duc-Tan Tran

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DTDuc-Tan Tran
Duc-Tan Tran
Tu NguyenTu Nguyen
Tu Nguyen
PKPhung Cong Phi Khanh
Phung Cong Phi Khanh
DTDuc-Tan Tran
Duc-Tan Tran
Cow behavior recognition systems support the assessment of cows’ condition by providing their behavior information. Accelerometers are particularly suited for a non-invasive solution for the development of these monitoring systems. They are cheap and simple in setting up and providing high-performance recognition when using machine learning algorithms. The activity complexity of animals brings challenges in real context applications because different behaviors may have similar acceleration data. The reason is that they contain similar gestures, for example, feeding and standing. In our previous work, we proposed a cows’ behavior classifier based on leg-mounted acceleration data. The distinguishing of similar behaviors, such as feeding and standing, is limited by the data. This study presents a new efficient cow behavior recognition system based on combining leg-mounted and collar-mounted accelerometers. Significantly, the acceleration data from these two sensors were synchronized. Therefore, we can substantially expand the amount of information for classification purposes. Our approach identifies four cow behaviors: walking, feeding, lying, and standing. Random Forest algorithm with our extracted features (root mean square, standard deviation, and mean) and 16-second data window (a sample/second) offer excellent performance when identifying all concerning behaviors: feeding (0.914 accuracy, 0.884 sensitivity, 0.956 positive predictive value), lying (0.998, 0.996, 1), standing (0.88, 0.928, 0.842), and walking (0.998, 0.996, 0.998). These performances are better than other existing works, especially in our experiments with free-grazing cows.

3 May 2022 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
NVN. H. Van
N. H. Van
PTP. Van Thanh
P. Van Thanh
DTD. N. Tran
D. N. Tran
DTDuc-Tan Tran
Duc-Tan Tran

21 November 2017 in Geomatics, Natural Hazards and Risk
Verified
Journal Article
Open access
QGQuoc Anh Gian
Quoc Anh Gian
DTDuc-Tan Tran
Duc-Tan Tran
DNDinh Chinh Nguyen
Dinh Chinh Nguyen
VNViet-Ha Nhu
Viet-Ha Nhu
Dieu Tien BuiDieu Tien Bui
Dieu Tien Bui
This paper proposes and implements an early warning and monitoring system for rainfall-induced landslide (named as EWMRIL) with a case study at the Nam Dan landslide (northern Vietnam). The proposed system consists of six sensor nodes and one rainfall station that are used to sense large amounts of data in real-time such as soil moisture, pore-water pressure (PWP), movement status, and rainfall. In addition, a new flexible configuration for the wireless communication system is proposed that is capable not only to save the energy consuming but also to ensure the reliability of the system. Using wireless communication system, the sensed data were sent to the computer station for analyzing and predicting the instability of the landslide in terms of factor of safety (FoS) using the finite element seepage analysis and the limit equilibrium slope stability analysis methods. These methods are available in the SEEP/W and SLOPE/W modules of the GeoStudio software. Based on the analyzing results, the system proposed three warning levels for the landslide Early, Intermediate, and Imminent. Experiment result in the rainy season from August to September 2016 has proven the validity of the EWMRIL system. The result of this study is useful for landslide risk prevention and management in landslide prone-areas.

14 August 2018 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
VPVan Thanh Pham
Van Thanh Pham
DTDuc-Tan Tran
Duc-Tan Tran
DNDinh-Chinh Nguyen
Dinh-Chinh Nguyen
NANguyen Duc Anh
Nguyen Duc Anh
DDDang Nhu Dinh
Dang Nhu Dinh
KSKumbesan Sandrasegaran
Kumbesan Sandrasegaran

27 May 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DTDuc-Tan Tran
Duc-Tan Tran
SLSebastien Li-Thiao-Te
Sebastien Li-Thiao-Te
YFYves-Michel Frapart
Yves-Michel Frapart
Electron paramagnetic resonance (EPR) is a spectroscopy and imaging method based on detecting the spin resonance of electrons. EPR is particularly suited for detecting and quantifying free radicals and biological markers of oxidative stress, for which it is the only quantitative imaging method at the moment. Its application in clinical contexts is a major challenge because of the lack of standardized procedures for estimating the measurement quality. Previous work analyzed the Lorentzian model of single-line EPR spectra in the derivative limit. For the general case, a modified acquisition procedure called overmodulation improves the signal-to-noise ratio (SNR). This article studies single-line EPR spectra with Lorentzian line shape under overmodulation and proposes maximum likelihood estimates (MLEs) as well as formulas for the expected relative error. The results are validated with simulated spectra and in vitro experimental results. The computed relative error is shown to be a good estimate of the observed instrumental variation.

20 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
VPVan Thanh Pham
Van Thanh Pham
DNDuc Anh Nguyen
Duc Anh Nguyen
NDNhu Dinh Dang
Nhu Dinh Dang
HPHong Hai Pham
Hong Hai Pham
VTVan An Tran
Van An Tran
DTDuc-Tan Tran
Duc-Tan Tran
Accurate step counting is essential for indoor positioning, health monitoring systems, and other indoor positioning services. There are several publications and commercial applications in step counting. Nevertheless, over-counting, under-counting, and false walking problems are still encountered in these methods. In this paper, we propose to develop a highly accurate step counting method to solve these limitations by proposing four features: Minimal peak distance, minimal peak prominence, dynamic thresholding, and vibration elimination, and these features are adaptive with the user’s states. Our proposed features are combined with periodicity and similarity features to solve false walking problem. The proposed method shows a significant improvement of 99.42% and 96.47% of the average of accuracy in free walking and false walking problems, respectively, on our datasets. Furthermore, our proposed method also achieves the average accuracy of 97.04% on public datasets and better accuracy in comparison with three commercial step counting applications: Pedometer and Weight Loss Coach installed on Lenovo P780, Health apps in iPhone 5s (iOS 10.3.3), and S-health in Samsung Galaxy S5 (Android 6.01).