Jong Seob Jeong

Prof. Jong Seob Jeong


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2011 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
JJJong Seob Jeong
Jong Seob Jeong
JLJung Woo Lee
Jung Woo Lee
CLChang Yang Lee
Chang Yang Lee
STShia Yen Teh
Shia Yen Teh
ALAbraham Lee
Abraham Lee
KSK. Kirk Shung
K. Kirk Shung

1 February 2013 in Ultrasonics
Verified
Journal Article
Closed access
JJJong Seob Jeong
Jong Seob Jeong
KSK. Kirk Shung
K. Kirk Shung

1 September 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
CPChan Yuk Park
Chan Yuk Park
JSJin Ho Sung
Jin Ho Sung
JJJong Seob Jeong
Jong Seob Jeong

1 January 2013 in Ultrasonics
Verified
Journal Article
Closed access
JLJungwoo Lee
Jungwoo Lee
JJJong Seob Jeong
Jong Seob Jeong
K. Kirk ShungK. Kirk Shung
K. Kirk Shung

13 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JSJinho Sung
Jinho Sung
JJJong Seob Jeong
Jong Seob Jeong
In most commercial single-element intravascular ultrasound (IVUS) transducers, with 20 MHz to 40 MHz center frequencies, a conductive adhesive is used to bond a micro-sized cable for the signal line to the surface of the transducer aperture (<1 mm × 1 mm size) where ultrasound beam is generated. Therefore, the vibration of the piezoelectric layer is significantly disturbed by the adhesive with the signal line, thereby causing problems, such as reduced sensitivity, shortened penetration depth, and distorted beam profile. This phenomenon becomes more serious as the center frequency of the IVUS transducer is increased, and the aperture size becomes small. Therefore, we propose a novel IVUS acoustic stack employing asymmetric electrodes with conductive and non-conductive backing blocks. The purpose of this study is to verify the extent of performance degradation caused by the adhesive with the signal line, and to demonstrate how much performance degradation can be minimized by the proposed scheme. Finite element analysis (FEA) simulation was conducted, and the results show that −3 dB, −6 dB, and −10 dB penetration depths of the conventional transducer were shortened by 20%, 25%, and 19% respectively, while those of the proposed transducer were reduced only 3%, 4%, and 0% compared with their ideal transducers which have the same effective aperture size. Besides, the proposed transducer improved the −3 dB, −6 dB, and −10 dB penetration depths by 15%, 12%, and 10% respectively, compared with the conventional transducer. We also fabricated a 60 MHz IVUS transducer by using the proposed technique, and high-resolution IVUS B-mode (brightness mode) images were obtained. Thus, the proposed scheme can be one of the potential ways to provide more uniform beam profile resulting in improving the signal to noise ratio (SNR) in IVUS image.

1 August 2012 in Ultrasonics
Verified
Journal Article
Closed access
JJJong Seob Jeong
Jong Seob Jeong
Jin Ho ChangJin Ho Chang
Jin Ho Chang
KSK. Kirk Shung
K. Kirk Shung