Yan Chen

Dr. Yan Chen


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
YXYulong Xie
Yulong Xie
MTMatthew Tyler
Matthew Tyler
JHJennifer Huckett
Jennifer Huckett
RBRosemarie Bartlett
Rosemarie Bartlett
YCYan Chen
Yan Chen
MRMichael Rosenberg
Michael Rosenberg
Building energy codes are essential tools for achieving energy efficiency in buildings. However, the full energy savings potential of these codes can only be realized if buildings are constructed in compliance with them. Therefore, evaluating building energy code compliance is crucial in bridging the gap between the energy efficiency requirements set by energy codes and the actualized energy savings achieved. An energy code compliance evaluation serves as a mechanism to assess construction practices, evaluate the effectiveness of code enforcement, identify gaps in compliance, and guide strategies for improvement through training and education. Conducting code compliance evaluation activities involves field studies that require careful design and significant resources. Historically, more emphasis has been placed on developing and adopting building energy codes, while efforts to evaluate compliance have been relatively limited and lacking consistent approaches. The passage of the 2009 American Recovery and Reinvestment Act (ARRA), which mandated that states create plans for achieving 90% compliance within eight years, stimulated the need for an energy code compliance evaluation. As a result, federal, state, and local governments, and utilities have invested in the development of methodologies and tools for code compliance evaluation studies. This paper reviews the code compliance evaluation studies conducted in the United States over the past three decades. It describes and compares the methodologies and metrics used to assess building energy code compliance, summarizes the general elements and steps involved in the evaluation process, and discusses common issues in these studies. Over time, code compliance evaluation methodologies have evolved from isolated development within individual states, regions, and utilities, to widely accepted protocols applicable across different states and local jurisdictions. There has been a transition in compliance metrics, shifting from historical compliance rates to energy-consumption-oriented approaches.

23 June 2020
Verified
Conference Paper
Open access
DBDavid Blum
David Blum
FJFilip Jorissen
Filip Jorissen
SHSen Huang
Sen Huang
YCYan Chen
Yan Chen
JAJavier Arroyo
Javier Arroyo
MSMarina Sofos
Marina Sofos

7 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
YXYulong Xie
Yulong Xie
MHMark Halverson
Mark Halverson
RBRosemarie Bartlett
Rosemarie Bartlett
YCYan Chen
Yan Chen
MRMichael Rosenberg
Michael Rosenberg
MRMichael Reiner
Michael Reiner
Building energy code compliance is the crucial link between the actual energy savings and the efficiency prescribed in energy codes. A research project aiming to identify opportunities to reduce energy consumption in new single-family residential construction by increasing compliance with the building energy code was conducted in several states of the United States. The study was comprised of three phases: (1) a baseline study to document typical practice and identify opportunities for improvement based on empirical data gathered from the field; (2) an education and training phase targeting the opportunities identified; and (3) a post-study to assess whether a reduction in average state-wide energy use could be achieved following the education and training phase. We proposed a novel methodology based on large-scale building energy simulation inferred by limited field data to assess the performance of a large population of homes. This paper presents the methodology, findings, and results of this study. The state-wide average energy consumption decreased at Phase III from Phase I for five of the seven states involved in the analysis. The measure-level savings potential analysis shows an overall reduction. Overall, the training and education phase plays a recognizable role in improving compliance with building energy codes.

1 December 2016 in Automation in Construction
Verified
Journal Article
Closed access
YCYan Chen
Yan Chen
STStephen Treado
Stephen Treado
JMJohn Messner
John Messner

18 September 2025 in arXiv
Verified
Preprint
Open access
PDF file
HWHanlong Wan
Hanlong Wan
XLXing Lu
Xing Lu
YCYan Chen
Yan Chen
KDKarthik Devaprasad
Karthik Devaprasad
LHLaura Hinkle
Laura Hinkle
Dynamic energy systems and controls require advanced modeling frameworks to design and test supervisory and fault tolerant strategies. Modelica is a widely used equation based language, but developing control modules is labor intensive and requires specialized expertise. This paper examines the use of large language models (LLMs) to automate the generation of Control Description Language modules in the Building Modelica Library as a case study. We developed a structured workflow that combines standardized prompt scaffolds, library aware grounding, automated compilation with OpenModelica, and human in the loop evaluation. Experiments were carried out on four basic logic tasks (And, Or, Not, and Switch) and five control modules (chiller enable/disable, bypass valve control, cooling tower fan speed, plant requests, and relief damper control). The results showed that GPT 4o failed to produce executable Modelica code in zero shot mode, while Claude Sonnet 4 achieved up to full success for basic logic blocks with carefully engineered prompts. For control modules, success rates reached 83 percent, and failed outputs required medium level human repair (estimated one to eight hours). Retrieval augmented generation often produced mismatches in module selection (for example, And retrieved as Or), while a deterministic hard rule search strategy avoided these errors. Human evaluation also outperformed AI evaluation, since current LLMs cannot assess simulation results or validate behavioral correctness. Despite these limitations, the LLM assisted workflow reduced the average development time from 10 to 20 hours down to 4 to 6 hours per module, corresponding to 40 to 60 percent time savings. These results highlight both the potential and current limitations of LLM assisted Modelica generation, and point to future research in pre simulation validation, stronger grounding, and closed loop evaluation.

13 December 2020
Verified
Conference Paper
Closed access
FMFanzhong Meng
Fanzhong Meng
YCYan Chen
Yan Chen
YFYuan Fang
Yuan Fang
Based on planar Schottky diode process, a single balanced mixer MMIC is presented with the Schottky diodes and passive elements integrated on one chip. The mixer has a three line coupled Marchand balun to combine the RF and LO signals. A conversion loss as low as 4.65dB@79GHz is obtained with the LO power of 13dBm in down-conversion mode with the IF fixed at 1GHz. The mixer chip exhibits an IF bandwidth of more than 30GHz at an RF frequency of 75GHz to 100GHz with a LO signal of 70GHz. The final size of the chip is only 1.00mm × 1.20mm.