Chih-Cheng Lu

Prof. Dr. Chih-Cheng Lu

Department of Intelligent Automation Engineering, National Taipei University of Technology, Taipei 10608, Taiwan
+1

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
JHJeff Huang
Jeff Huang
A new class of tri-axial miniature magnetometer consisting of a planar fluxgate structure with an orthogonal ferromagnetic fluxguide centrally situated over the magnetic cores is presented. The magnetic sensor possesses a cruciform ferromagnetic core placed diagonally upon the square excitation coil under which two pairs of pick-up coils for in-plane field detection are allocated. Effective principles and analysis of the magnetometer for 3-D field vectors are described and verified by numerically electromagnetic simulation for the excitation and magnetization of the ferromagnetic cores. The sensor is operated by applying the second-harmonic detection technique that can verify V-B relationship and device responsivity. Experimental characterization of the miniature fluxgate device demonstrates satisfactory spatial magnetic field detection results in terms of responsivity and noise spectrum. As a result, at an excitation frequency of 50 kHz, a maximum in-plane responsivity of 122.4 V/T appears and a maximum out-of-plane responsivity of 11.6 V/T is obtained as well. The minimum field noise spectra are found to be 0.11 nT/√Hz and 6.29 nT/√Hz, respectively, in X- and Z-axis at 1 Hz under the same excitation frequency. Compared with the previous tri-axis fluxgate devices, this planar magnetic sensor with an orthogonal fluxguide provides beneficial enhancement in both sensory functionality and manufacturing simplicity. More importantly, this novel device concept is considered highly suitable for the extension to a silicon sensor made by the current CMOS-MEMS technologies, thus emphasizing its emerging applications of field detection in portable industrial electronics.

19 January 2010 in Sensors
Verified
Journal Article
Open access
PDF file
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
YHYong-Sheng Huang
Yong-Sheng Huang
JHJun-Wei Huang
Jun-Wei Huang
CCChien-Kuo Chang
Chien-Kuo Chang
SWSheng-Po Wu
Sheng-Po Wu
An innovative fabrication method to produce a macroporous Si surface by employing an anodic aluminium oxide (AAO) nanopore array layer as an etching template is presented. Combining AAO with a reactive ion etching (RIE) processes, a homogeneous and macroporous silicon surface can be effectively configured by modulating AAO process parameters and alumina film thickness, thus hopefully replacing conventional photolithography and electrochemical etch methods. The hybrid process integration is considered fully CMOS compatible thanks to the low-temperature AAO and CMOS processes. The gas-sensing characteristics of 50 nm TiO2 nanofilms deposited on the macroporous surface are compared with those of conventional plain (or non-porous) nanofilms to verify reduced response noise and improved sensitivity as a result of their macroporosity. Our experimental results reveal that macroporous geometry of the TiO2 chemoresistive gas sensor demonstrates 2-fold higher (~33%) improved sensitivity than a non-porous sensor at different levels of oxygen exposure. In addition, the macroporous device exhibits excellent discrimination capability and significantly lessened response noise at 500 °C. Experimental results indicate that the hybrid process of such miniature and macroporous devices are compatible as well as applicable to integrated next generation bio-chemical sensors.

30 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
JHJeff Huang
Jeff Huang
PCPo-Kai Chiu
Po-Kai Chiu
SCShih-Liang Chiu
Shih-Liang Chiu
JJJen-Tzong Jeng
Jen-Tzong Jeng
This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB) substrate and electrically connected to each other similar to the current “flip chip” concept in semiconductor package. This sensor is soldered together by reversely flipping a 5 cm × 3 cm PCB substrate to the other identical one which includes dual magnetic cores, planar pick-up coils, and 3-D excitation coils constructed by planar Cu interconnections patterned on PCB substrates. Principles and analysis of the fluxgate sensor are introduced first, and followed by FEA electromagnetic modeling and simulation for the proposed sensor. Comprehensive characteristic experiments of the miniature fluxgate device exhibit favorable results in terms of sensitivity (or “responsivity” for magnetometers) and field noise spectrum. The sensor is driven and characterized by employing the improved second-harmonic detection technique that enables linear V-B correlation and responsivity verification. In addition, the double magnitude of responsivity measured under very low frequency (1 Hz) magnetic fields is experimentally demonstrated. As a result, the maximum responsivity of 593 V/T occurs at 50 kHz of excitation frequency with the second harmonic wave of excitation; however, the minimum magnetic field noise is found to be 0.05 nT/Hz1/2 at 1 Hz under the same excitation. In comparison with other miniature planar fluxgates published to date, the fluxgate magnetic sensor with flip chip configuration offers advances in both device functionality and fabrication simplicity. More importantly, the novel design can be further extended to a silicon-based micro-fluxgate chip manufactured by emerging CMOS-MEMS technologies, thus enriching its potential range of applications in modern engineering and the consumer electronics market.

22 March 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
RFRui Fang
Rui Fang
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
CCCheng-Ta Chuang
Cheng-Ta Chuang
WCWen-Han Chang
Wen-Han Chang

26 September 2011 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JJJen-Tzong Jeng
Jen-Tzong Jeng
THTing-Yu Hsu
Ting-Yu Hsu
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
Responsivity and field noise of a bridge-type GMR magnetometer modulated by a sinusoidal alternating magnetic field were investigated in this work. The odd harmonics of output voltage were found to be more sensitive to external dc fields in comparison with the even harmonics. By detecting the field-modulated output with a reference square wave at the 1st, 3rd, or 5th harmonic of modulation frequency, the sensor responses to external fields are bipolar, non-hysteretic, and quite linear with proper modulation amplitudes. The minimum field noises were 5, 2.5, and 5 nT/√Hz at 1 Hz for the 1st, 3rd, and 5th harmonics, respectively, with power consumption less than 10 mW. The proposed operation method is promising for application to electronic compasses.

25 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
YLYu-Jung Li
Yu-Jung Li
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
A miniature intra-oral dental implant system including a built-in biosensor device is proposed in this article. The dental implant system, or platform, is replaced over maxilla and allows relatively non-invasive procedures for a novel biosensing scheme for human blood analysis. Due to placement of the implant fixture, periodontal ligaments and the pulp structure, which are regarded as the main origin of pain, are thus removed, and long-term, continuous blood analysis and management through maxillary bone marrow becomes achievable through the dental implant platform. The new pathway of biological sensing is for the first time presented to realize an accurate and painless approach without injections. The dental implant system mainly consists of an implant fixture and a prosthetic abutment, a biosensor module, a bluetooth 4.0 wireless module and a dc button cell battery. The electrochemical biosensor possesses three electrodes, including working, reference and counter ones, which are arranged to pass through the titanium implant fixture below the biosensor module. The electrodes are exposed to the blood pool inside the maxillary bone marrow and perform oxidation/reduction reactions with the coating of biosensing enzyme. To prove the proposed platform, the immobilization process of glucose oxidase (GOD) enzyme and in vitro detections of glucose levels are successfully carried out, and proven sensitivity, linearity and repeatability of the glucose biosensor system are obtained. Moreover, a preliminary canine animal model adopting the new pathway shows significant consistency with the traditional method through dermal pricks for blood sugar detection. Despite the prospective results, further challenges in engineering implementation and clinical practices are addressed and discussed. In brief, the novel biosensing pathway and intra-oral biosensor platform may increasingly reveal their promising value and feasibilities in current bio-medical analysis, diagnosis, drug release and even healthcare technologies.