Xiaoling Cui

Dr. Xiaoling Cui

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Energy and Buildings
Verified
Journal Article
Closed access
GSGuochen Sang
Guochen Sang
YCYanzhou Cao
Yanzhou Cao
MFMin Fan
Min Fan
GLGeyang Lu
Geyang Lu
YZYiyun Zhu
Yiyun Zhu
XCXiaoling Cui
Xiaoling Cui

2 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XCXiaoling Cui
Xiaoling Cui
YZYangkai Zhang
Yangkai Zhang
GSGuochen Sang
Guochen Sang
WWWenkang Wang
Wenkang Wang
YZYiyun Zhu
Yiyun Zhu
LZLei Zhang
Lei Zhang
In areas where solar energy is abundant, such as the Tibetan plateau, passive solar buildings are attracting more and more attention and becoming a popular form of rural building. However, it is often difficult to achieve the satisfactory indoor thermal environment in a local rural passive solar single-family house. In order to improve the indoor thermal environment of passive solar buildings through building design, a systematic study of rural single-family buildings in Tibet was conducted. The basic parameters were investigated on the outdoor thermal environment, space-arrangement, envelope structure, and the indoor thermal environment. The building model considering space-arrangement modes was developed based on the survey data in multi-space passive solar buildings. The general physical and mathematical analysis models of multi-space passive solar buildings were established based on the heat transfer theory. Furthermore, the effects of space-arrangement and exterior wall thermal resistance on indoor air temperature were analyzed by numerical simulation. Results show that the indoor air temperature of the passive solar building is influenced by space-arrangement and wall thermal resistance together. When the space-arrangement of the building model was changed from “north-south through type” (mode a) to “through and separation combination” (mode b) and “north-south separation” (mode c), the indoor air temperature of the living room increased from 8.8 °C to 10.6 °C and 11.6 °C, with increases of 20.5% and 31.8%, respectively. In addition, equally increasing the thermal resistance of exterior walls in different orientations has different effects on the indoor air temperature. In the space-arrangement mode c, comparing with the temperature increment of the living room and bedroom caused by increasing thermal resistance of the south wall and north wall, the temperature increment of the living room caused by increasing thermal resistance of the east/west wall increased by 151.7% and 32.7%, and that of the bedroom increased by 609.1% and 239.1% respectively. This study can provide a reference for the optimal design of passive solar buildings in solar energy abundant areas.

24 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
XCXiaoling Cui
Xiaoling Cui
XDXiaoyun Du
Xiaoyun Du
YCYanzhou Cao
Yanzhou Cao
GSGuochen Sang
Guochen Sang
YZYangkai Zhang
Yangkai Zhang
YZYiyun Zhu
Yiyun Zhu
Efficient use of solar energy by thermal energy storage composites and utilizing environmentally friendly cementitious materials are important trends for sustainable building composite materials. In this study, a paraffin/low density polyethylene (LDPE) composite shape-stabilized phase change material (SSPCM) was prepared and incorporated into a sulphoaluminate cement (SAC) mortar to prepare thermal energy storage mortar. The thermal and mechanical properties of SSPCM and a SAC-based thermal energy storage material (SCTESM) were investigated. The result of differential scanning calorimeter (DSC) analysis indicates that the latent heat of SCTESM is as high as 99.99 J/g. Thermogravimetric analysis demonstrates that the SCTESM does not show significant decomposition below 145 °C. The volume stability test shows the volume shrinkage percentage of the SCTESM is less than that of pure SAC mortar and far less than that of ordinary Portland cement mortar. The SCTESM has high early strength so that the compressive strength at 1-, 3-, and 7-day curing age is up to that at 28-day curing age of 67.5%, 78.3%, and 86.7%, respectively. Furthermore, a mathematical prediction model of the SCTESM compressive strength was proposed. The investigation of latent heat storage characteristics and the thermoregulating performance reveals that SCTESMs have the excellent capacity of heat storage and thermoregulating.

7 February 2023 in International Journal of Energy Research
Verified
Journal Article
Open access
PDF file
TGTeng Guo
Teng Guo
GSGuochen Sang
Guochen Sang
YZYangkai Zhang
Yangkai Zhang
XCXiaoling Cui
Xiaoling Cui
Phase change material (PCM) embedded in the building contributes to enhancing indoor thermal comfort and reducing the heating load in winter by absorbing/releasing solar energy. The application effects of PCM incorporated into a single-space passive solar building with the auxiliary heating system (AHS) were investigated numerically in the six representative regions of western China. In the calculation and analysis by the enthalpy model, it was found that the effectiveness of PCM greatly depended on local climate conditions, thickness, and location of PCM. The results indicated that it was necessary to adopt the AHS for winter heating of the passive solar building. On this basis of using AHS, it showed a favorable thermal energy storage effect after the application of PCM resulting in the minimum indoor air temperature being maintained above 15°C within the comfort range stably. The integrated discomfort degree in each region was decreased by more than 96% compared to the original building, and the average temperature in Lhasa was 2°C higher than that in Urumqi. Furthermore, the highest rate of energy saving and carbon dioxide emission saving in the six regions was 19.7% and 17.4% in Lhasa, and the lowest were 4.3% and 4.2% in Urumqi, while other regions were relatively close, respectively. As a result, it can be stated that for a passive solar building using the AHS during the heating period, PCM was the most suitable for application in Lhasa, unsuitable in Urumqi, and generally suitable in other regions.

6 July 2023 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Closed access
PDF file
YZYangkai Zhang
Yangkai Zhang
GSGuochen Sang
Guochen Sang
CZCaiyun Zhao
Caiyun Zhao
TGTeng Guo
Teng Guo
XCXiaoling Cui
Xiaoling Cui
SZSaisai Zou
Saisai Zou

1 September 2024 in Journal of the Croatian Association of Civil Engineers
Verified
Journal Article
Open access
PDF file
YZYiyun Zhu
Yiyun Zhu
LLLU LIU
LU LIU
GSGuochen Sang
Guochen Sang
XCXiaoling Cui
Xiaoling Cui
This study proposed an interior thermal comfort test to enhance the interior thermal comfort of traditional houses in the Guan Zhong region of the Shaanxi Province during winter. The study was conducted in Xiaoliu village by employing field tests and a questionnaire survey. The field tests and analysis revealed that the thermal comfort of traditional houses in this region is poor, the spatial layout of the houses is unsuitable for conserving heat, the thermal properties of the enclosure walls are inadequate, and the mode of heating is inefficient. The heat transfer parameters, heat lost and gained through fabrics, and thermal properties of nanomaterials have been used to improve the thermal comfort analysis. Combined with the local economic conditions, passive design strategies such as optimizing the spatial layout, improving the thermal insulation performance of the enclosure walls, and using solar energy were implemented. The simulation results indicate that energy consumption can be significantly reduced, and the indoor thermal comfort of traditional houses can be enhanced by reasonably dividing the indoor space, increasing the thermal insulation performance of the enclosure walls, and making better use of solar energy and natural ventilation. Therefore, to improve thermal comfort and reduce the energy load of traditional houses in the Guan Zhong region, it is necessary to adopt passive optimisation strategies.