The following paper examines a time-efficient method for detecting biological warfare agents (BWAs). The method is based on a system of a Love-wave immunosensor combined with a microfluidic chip which detects BWA samples in a dynamic mode. In this way a continuous flow-through of the sample is created, promoting the reaction between antigen and antibody and allowing a fast detection of the BWAs. In order to prove this method, static and dynamic modes have been simulated and different concentrations of BWA simulants have been tested with two immunoreactions: phage M13 has been detected using the mouse monoclonal antibody anti-M13 (AM13), and the rabbit immunoglobulin (Rabbit IgG) has been detected using the polyclonal antibody goat anti-rabbit (GAR). Finally, different concentrations of each BWA simulants have been detected with a fast response time and a desirable level of discrimination among them has been achieved.
A new method of depositing tin dioxide nanofibers in order to develop chemical sensors is presented. It involves an electrospinning process with in-plane electrostatic focusing over micromechanized substrates. It is a fast and reproducible method. After an annealing process, which can be performed by the substrate heaters, it is observed that the fibers are intertwined forming porous networks that are randomly distributed on the substrate. The fiber diameters oscillate from 100 nm to 200 nm and fiber lengths reach several tens of microns. Each fiber has a polycrystalline structure with multiple nano-grains. The sensors have been tested for the detection of acetone and hydrogen peroxide (precursors of the explosive triacetone triperoxide, TATP) in air in the ppm range. High and fast responses to these gases have been obtained.
Love-wave gas sensors based on surface functionalized iron oxide nanoparticles has been developed in this research. Amino-terminated iron oxide nanoparticles were deposited, by a spin coating technique, onto the surface of Love-wave sensors, as a very reproducible gas-sensing layer. The gases tested were organic solvents, such as butanol, isopropanol, toluene and xylene, for a wide and low concentration range, obtaining great responses, fast response times of a few minutes (the time at which the device produced a signal change equal to 90%), good reproducibilities, and different responses for each detected solvent. The estimated limits of detection obtained have been very low for each detected compound, about 1 ppm for butanol, 12 ppm for isopropanol, 3 ppm for toluene and 0.5 ppm for xylene. Therefore, it is demonstrated that this type of acoustic wave sensor, with surface amino-functionalized nanoparticles, is a good alternative to those ones functionalized with metal nanoparticles, which result very expensive sensors to achieve worse results.