Wyatt Felt

Dr. Wyatt Felt

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WFWyatt Felt
Wyatt Felt
JSJessica C Selinger
Jessica C Selinger
JDJ Maxwell Donelan
J Maxwell Donelan
CRC David Remy
C David Remy
This paper demonstrates methods for the online optimization of assistive robotic devices such as powered prostheses, orthoses and exoskeletons. Our algorithms estimate the value of a physiological objective in real-time (with a body “in-the-loop”) and use this information to identify optimal device parameters. To handle sensor data that are noisy and dynamically delayed, we rely on a combination of dynamic estimation and response surface identification. We evaluated three algorithms (Steady-State Cost Mapping, Instantaneous Cost Mapping, and Instantaneous Cost Gradient Search) with eight healthy human subjects. Steady-State Cost Mapping is an established technique that fits a cubic polynomial to averages of steady-state measures at different parameter settings. The optimal parameter value is determined from the polynomial fit. Using a continuous sweep over a range of parameters and taking into account measurement dynamics, Instantaneous Cost Mapping identifies a cubic polynomial more quickly. Instantaneous Cost Gradient Search uses a similar technique to iteratively approach the optimal parameter value using estimates of the local gradient. To evaluate these methods in a simple and repeatable way, we prescribed step frequency via a metronome and optimized this frequency to minimize metabolic energetic cost. This use of step frequency allows a comparison of our results to established techniques and enables others to replicate our methods. Our results show that all three methods achieve similar accuracy in estimating optimal step frequency. For all methods, the average error between the predicted minima and the subjects’ preferred step frequencies was less than 1% with a standard deviation between 4% and 5%. Using Instantaneous Cost Mapping, we were able to reduce subject walking-time from over an hour to less than 10 minutes. While, for a single parameter, the Instantaneous Cost Gradient Search is not much faster than Steady-State Cost Mapping, the Instantaneous Cost Gradient Search extends favorably to multi-dimensional parameter spaces.

26 October 2015 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
WFWyatt Felt
Wyatt Felt
KCKhai Yi Chin
Khai Yi Chin
CRC. David Remy
C. David Remy
The inherent compliance of soft fluidic actuators makes them attractive for use in wearable devices and soft robotics. Their flexible nature permits them to be used without traditional rotational or prismatic joints. Without these joints, however, measuring the motion of the actuators is challenging. Actuator-level sensors could improve the performance of continuum robots and robots with compliant or multi-degree-of-freedom joints. We make the reinforcing braid of a pneumatic artificial muscle (PAM or McKibben muscle) “smart” by weaving it from conductive insulated wires. These wires form a solenoid-like circuit with an inductance that more than doubles over the PAM contraction. The reinforcing and sensing fibers can be used to measure the contraction of a PAM actuator with a simple linear function of the measured inductance, whereas other proposed self-sensing techniques rely on the addition of special elastomers or transducers, the technique presented in this paper can be implemented without modifications of this kind. We present and experimentally validate two models for Smart Braid sensors based on the long solenoid approximation and the Neumann formula, respectively. We test a McKibben muscle made from a Smart Braid in quasi-static conditions with various end loads and in dynamic conditions. We also test the performance of the Smart Braid sensor alongside steel.

11 June 2018 in Autonomous Robots
Verified
Journal Article
Closed access
PDF file
WFWyatt Felt
Wyatt Felt
MTMaria J. Telleria
Maria J. Telleria
TAThomas F. Allen
Thomas F. Allen
GHGabriel Hein
Gabriel Hein
JPJonathan B. Pompa
Jonathan B. Pompa
CRC. David Remy
C. David Remy

1 May 2014 in Journal of Power Sources
Verified
Journal Article
Closed access
GBGuido Bender
Guido Bender
WFWyatt Felt
Wyatt Felt
MUMichael Ulsh
Michael Ulsh

29 October 2018 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
MRMatthew A. Robertson
Matthew A. Robertson
MMMasato Murakami
Masato Murakami
WFWyatt Felt
Wyatt Felt
JPJamie Paik
Jamie Paik
A variety of reconfigurable surface devices, utilizing large numbers of actuated physical pixels to produce discretized three-dimensional contours, have been developed for different purposes in research and industry. The difficulty of integrating many actuators in close configuration has limited the DOF and resolution and performance of existing devices. Utilizing vacuum power and soft material actuators, we have developed a soft reconfigurable surface (SRS) with multimodal control and performance capabilities. The SRS is comprised of a square grid array of linear vacuum-powered soft pneumatic actuators, built into plug-and-play modules which enable the arrangement, consolidation, and control of many DoF. In addition to the practical benefits of system integration, this architecture facilitates the construction of customized assemblies with an overall compact form factor. A series of experiments is performed to illustrate and validate the versatility of the SRS for achieving diverse tasks including force-controlled modulation of interface pressure through integrated sensors, lateral manipulation of a variety of objects, static and dynamic shape and pattern generation for haptic interaction, and variable surface stiffness tuning. This SRS concept is scalable, space efficient, and features diverse functional potential. This will extend the utility and accessibility of tangible robotic interfaces for future applications from industrial to home and personal use.

1 September 2017 in Soft Robotics
Verified
Journal Article
Closed access
WFWyatt Felt
Wyatt Felt
KCKhai Yi Chin
Khai Yi Chin
CRC. David Remy
C. David Remy
This article experimentally investigates the potential of using flexible, inductance-based contraction sensors in the closed-loop motion control of soft robots. Accurate motion control remains a highly challenging task for soft robotic systems. Precise models of the actuation dynamics and environmental interactions are often unavailable. This renders open-loop control impossible, while closed-loop control suffers from a lack of suitable feedback. Conventional motion sensors, such as linear or rotary encoders, are difficult to adapt to robots that lack discrete mechanical joints. The rigid nature of these sensors runs contrary to the aspirational benefits of soft systems. As truly soft sensor solutions are still in their infancy, motion control of soft robots has so far relied on laboratory-based sensing systems such as motion capture, electromagnetic (EM) tracking, or Fiber Bragg Gratings. In this article, we used embedded flexible sensors known as Smart Braids to sense the contraction of McKibben muscles through changes in inductance. We evaluated closed-loop control on two systems: a revolute joint and a planar, one degree of freedom continuum manipulator. In the revolute joint, our proposed controller compensated for elasticity in the actuator connections. The Smart Braid feedback allowed motion control with a steady-state root-mean-square (RMS) error of [1.5]°. In the continuum manipulator, Smart Braid feedback enabled tracking of the desired tip angle with a steady-state RMS error of [1.25]°. This work demonstrates that Smart Braid sensors can provide accurate position feedback in closed-loop motion control suitable for field applications of soft robotic systems.