zhaojun li

zhaojun li

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
XWXiangyu Wei
Xiangyu Wei
XSXiaokang Song
Xiaokang Song
ZLzhaojun li
zhaojun li
LHLiangtao Hou
Liangtao Hou
ZLZhaojun Li
Zhaojun Li
LRLingling Ran
Lingling Ran
We experimentally demonstrated a high sensitive gas pressure sensor, which also has more concise processing steps and lower cost. The sensor was fabricated by splicing the single-mode fiber (SMF) and a short section of hollow-core fiber (HCF) which was filled with a Polydimethylsiloxane (PDMS) film to form an enclosed air microcavity with the length of 55 μm. The thin PDMS film also plays a role in reflecting the beam. The thermo-optical effect and the thickness of PDMS film can affect the cavity that is sensitive to external pressure. When the thickness of the PDMS membrane is 3 μm, the measured gas pressure sensitivity reaches to 52.143 nm/Mpa, the linearity is 99.86%, and the cross-sensitivity of the gas pressure over temperature is lower than 2.51 × 10 −3 Mpa/°C. Moreover, the compact structure, high sensitivity, high mechanical strength, and convenient fabrication make it suitable for measuring gas pressure in harsh conditions.

4 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZLzhaojun li
zhaojun li
LHLiangtao Hou
Liangtao Hou
LRLingling Ran
Lingling Ran
JKJing Kang
Jing Kang
JYJiuru Yang
Jiuru Yang
In this paper, a novel in-line modal interferometer for refractive index (RI) sensing is proposed and experimentally fabricated by cascading single-taper and multimode-double- cladding-multimode (MDM) fiber structure. Owing to evanescent field in taper area, the ultra-sensitive and linear intensity-responses to the varied surrounding RI are gained in both single- and double-pass structures. Moreover, the crosstalk from temperature can be effectively discriminated and compensated by means of the RI-free nature of MDM. The experimental results show that the RI sensitivities in single- and double-pass structures, respectively, reach 516.02 and 965.46 dB/RIU (RIU: refractive index unit), both with the slight wavelength shift (~0.2 nm). The temperature responses with respect to wavelength and intensity are 68.9 pm°C−1/0.103 dB°C−1 (single-pass structure) and 103 pm°C−1/0.082 dB·°C−1 (double-pass structure). So the calculated cross-sensitivity of intensity is constrained within 8.49 × 10−5 RIU/°C. In addition, our sensor presents high measurement-stability (~0.99) and low repeatability error (<4.8‰). On account of the ~620 μm size of taper, this compact sensor is cost-efficient, easy to fabricate, and very promising for the applications of biochemistry and biomedicine.