Henrik Gollee

Dr. Henrik Gollee

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2011 in Biological Cybernetics
Verified
Journal Article
Closed access
PDF file
PGPeter Gawthrop
Peter Gawthrop
ILIan Loram
Ian Loram
MLMartin Lakie
Martin Lakie
HGHenrik Gollee
Henrik Gollee

14 January 2011 in The Journal of Physiology
Verified
Journal Article
Closed access
ILIan Loram
Ian Loram
HGHenrik Gollee
Henrik Gollee
MLMartin Lakie
Martin Lakie
PGPeter J. Gawthrop
Peter J. Gawthrop

6 February 2014 in Biological Cybernetics
Verified
Journal Article
Open access
PDF file
PGPeter Gawthrop
Peter Gawthrop
ILIan Loram
Ian Loram
HGHenrik Gollee
Henrik Gollee
MLMartin Lakie
Martin Lakie
Two architectures of intermittent control are compared and contrasted in the context of the single inverted pendulum model often used for describing standing in humans. The architectures are similar insofar as they use periods of open-loop control punctuated by switching events when crossing a switching surface to keep the system state trajectories close to trajectories leading to equilibrium. The architectures differ in two significant ways. Firstly, in one case, the open-loop control trajectory is generated by a system-matched hold, and in the other case, the open-loop control signal is zero. Secondly, prediction is used in one case but not the other. The former difference is examined in this paper. The zero control alternative leads to periodic oscillations associated with limit cycles; whereas the system-matched control alternative gives trajectories (including homoclinic orbits) which contain the equilibrium point and do not have oscillatory behaviour. Despite this difference in behaviour, it is further shown that behaviour can appear similar when either the system is perturbed by additive noise or the system-matched trajectory generation is perturbed. The purpose of the research is to come to a common approach for understanding the theoretical properties of the two alternatives with the twin aims of choosing which provides the best explanation of current experimental data (which may not, by itself, distinguish beween the two alternatives) and suggesting future experiments to distinguish beween the two alternatives.

1 January 1999 in International Journal of Control
Verified
Journal Article
Closed access
RSRobert Shorten
Robert Shorten
RMRoderick Murray-Smith
Roderick Murray-Smith
RBRoger Bjorgan
Roger Bjorgan
HGHenrik Gollee
Henrik Gollee
The construction of non-linear dynamics by means of interpolating the behaviour of locally valid models offers an attractive and intuitively pleasing method of modelling non-linear systems. The approach is used in fuzzy logic modelling, operating regime based models, and non-linear statistical models. The model structure suggests that the composite local models can be used to interpret, in some appropriate manner, the overall non-linear dynamics. In this paper we demonstrate that the interpretation of these local models, in the context of multiple model structures, is not as straightforward as it might initially appear. We argue that the blended multiple model system can be interpreted in two ways as an interpolation of linearizations, or as a full parameterization of the system. The choice of interpretation affects experiment design, parameter identification, and model validation. We then show that, in some cases, the local models give insight into full model behaviour only in a very small region of state space. More alarmingly, we demonstrate that for off-equilibrium behaviour, subject to some approximation error, a non-unique parameterization of the model dynamics exists. Hence, qualitative conclusions drawn from the behaviour of an identified local model, e.g. regarding stable, unstable, nodal or complex behaviour, must be treated with extreme caution. The example of muscle modelling is used to illustrate these points clearly.

18 February 2010 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HGHenrik Gollee
Henrik Gollee
Ivan VolosyakIvan Volosyak
Ivan Volosyak
AMAngus J. McLachlan
Angus J. McLachlan
KHKenneth J. Hunt
Kenneth J. Hunt
AGAxel Gräser
Axel Gräser
A brain-computer interface (BCI) based on steady-state visual-evoked potentials (SSVEPs) is combined with a functional electrical stimulation (FES) system to allow the user to control stimulation settings and parameters. The system requires four flickering lights of distinct frequencies that are used to form a menu-based interface, enabling the user to interact with the FES system. The approach was evaluated in 12 neurologically intact subjects to change the parameters and operating mode of an abdominal stimulation system for respiratory assistance. No major influence of the FES on the raw EEG signal could be observed. In tests with a self-paced task, a mean accuracy of more than 90% was achieved, with detection times of approximately 7.7 s and an average information transfer rate of 12.5 bits/min. There was no significant dependency of the accuracy or time of detection on the FES stimulation intensity. The results indicate that the system could be used to control FES-based neuroprostheses with a high degree of accuracy and robustness.

15 March 2004 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
HGHenrik Gollee
Henrik Gollee
KHK.J. Hunt
K.J. Hunt
DWD.E. Wood
D.E. Wood
The aim of this study was to implement a new approach to feedback control of unsupported standing and to evaluate it in tests with an intact and a paraplegic subject. In our setup, all joints above the ankles are braced and stabilizing torque at the ankle is generated by electrical stimulation of the plantarflexor muscles. A previous study showed that short periods of unsupported standing with a paraplegic subject could be achieved. In order to improve consistency and reliability and to prolong the duration of standing, we have implemented several modifications to the control strategy. These include a simplified control structure and a different controller design method. While the reliability of standing is mainly limited by the muscle characteristics such as reduced strength and progressive fatigue, the results presented here show that the new strategy allows much longer periods (up to several minutes) of unsupported standing in paraplegia.