Dong Zhou

Dong Zhou

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
DZDong Zhou
Dong Zhou
Ahmed AbassAhmed Abass
Ahmed Abass
AEAshkan Eliasy
Ashkan Eliasy
HSHarald P. Studer
Harald P. Studer
AMAlexander Movchan
Alexander Movchan
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh
This paper aims to present a novel full-eye biomechanical material model that incorporates the characteristics of ocular tissues at microstructural level, and use the model to analyse the age-related stiffening in tissue behaviour. The collagen content in ocular tissues, as obtained using X-ray scattering measurements, was represented by sets of Zernike polynomials that covered both the cornea and sclera, then used to reconstruct maps of collagen fibril magnitude and orientation on the three-dimensional geometry of the eye globe. Fine-mesh finite-element (FE) models with eye-specific geometry were built and supported by a user-defined material model (UMAT), which considered the regional variation of fibril density and orientation. The models were then used in an iterative inverse modelling study to derive the material parameters that represent the experimental behaviour of ocular tissues from donors aged between 50 and 90 years obtained in earlierex vivostudies. Sensitivity analysis showed that reducing the number of directions that represented the anisotropy of collagen fibril orientation at each X-ray scattering measurement point from 180 to 16 would have limited and insignificant effect on the FE solution (0.08%). Inverse analysis resulted in material parameters that provided a close match with experimental intraocular pressure–deformation behaviour with a root mean square of error between 3.6% and 4.3%. The results also demonstrated a steady increase in mechanical stiffness in all ocular regions with age. A constitutive material model based on distributions of collagen fibril density and orientation has been developed to enable the accurate representation of the biomechanical behaviour of ocular tissues. The model offers a high level of control of stiffness and anisotropy across ocular globe, and therefore has the potential for use in planning surgical and medical procedures.

1 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DZDong Zhou
Dong Zhou
AEAshkan Eliasy
Ashkan Eliasy
Ahmed AbassAhmed Abass
Ahmed Abass
PMPetar Markov
Petar Markov
CWCharles Whitford
Charles Whitford
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh
This study aimed to analyse microstructure data on the density and orientation of collagen fibrils in whole eye globes and to propose an effective method for the preparation of data for use in numerical simulations of the eye’s biomechanical performance. Wide-angle X-ray scattering was applied to seven healthy ex-vivo human eyes. Each eye was dissected into an anterior and a posterior cup, and radial incisions were used to flatten the tissue before microstructure characterisation. A method was developed to use the microstructure data obtained for the dissected tissue to build realistic 3D maps of fibril density and orientation covering the whole eye globe. At the central cornea, 61.5±2.3% of fibrils were aligned within 45° sectors surrounding the two orthogonal directions. In contrast, more than one-third of the total fibril content was concentrated along the circumferential direction at the limbus (37.0±2.4%) and around the optic nerve head (34.8±2.1%). The insertion locations of the four recti muscles exhibited a preference in the meridional direction near the equator (38.6±3.9%). There was also a significant difference in fibril density between the limbus and other regions (ratio = 1.91±0.45, p <0.01 at the central cornea and ratio = 0.80±0.21, p <0.01 at the posterior pole). Characterisation of collagen fibril density and orientation across the whole ocular surface has been possible but required the use of a technique that involved tissue dissection and hence caused tissue damage. The method presented in this paper aimed to minimise the effect of dissection on the quality of obtained data and was successful in identifying fibril distribution trends that were compatible with earlier studies, which concentrated on localised areas of the ocular globe.

26 July 2016 in Experimental and Therapeutic Medicine
Verified
Journal Article
Open access
PDF file
ZCZheng Chen
Zheng Chen
QKQiaoting Kuang
Qiaoting Kuang
XLXue-Jun Lao
Xue-Jun Lao
JYJie Yang
Jie Yang
WHWeidong Huang
Weidong Huang
DZDong Zhou
Dong Zhou
The aim of the study was to investigate the possibility of human umbilical cord mesenchymal stem cells (UC-MSCs) surviving and differentiating into hepatocyte-like cells in partially hepatectomized model rats. MSCs were isolated from human umbilical cord and cultured with collagenase digestion. Cell surface markers were detected and fifth generation UC-MSCs were labeled with PKH26. The partially hepatectomized model rats were injected with the labeled human umbilical cord MSCs and transplanted through the portal vein. The survival of the labeled cells, in differentiation conditions and the expression of hepatic marker albumin were observed at post-transplantation 1, 2 and 3 weeks under a fluorescence microscope. It was found that the human umbilical cord MSCs could be cultured and amplified in vitro. Following transplantation to the partially hepatectomized liver of the model rat, the cells survived and expresses the hepatic marker albumin in vivo. After being labeled with PKH26, the cells were visualized as red fluorescence under a fluorescence microscope. In the frozen sections of the liver, the marked cells scattered around and most of them expressed albumin with green fluorescence under the fluorescence microscope. In conclusion, the transplanted human umbilical cord MSCs survived and differentiated into hepatocyte-like cells. The human umbilical cord MSCs may therefore be a main source of hepatocytes in transplantation.

DZDong Zhou
Dong Zhou
Ahmed AbassAhmed Abass
Ahmed Abass
AEAshkan Eliasy
Ashkan Eliasy
AMAlexander Movchan
Alexander Movchan
NMNatalia Movchan
Natalia Movchan
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh
Purpose: To simulate numerically the collagen fibril reorientation observed experimentally in the cornea. Methods: Fibril distribution in corneal strip specimens was monitored using X-ray scattering while under gradually increasing axial loading. The data were analysed at each strain level in order to quantify the changes in the angular distribution of fibrils with strain growth. The resulting relationship between stain and fibril reorientation was adopted in a constitutive model to control the mechanical anisotropy of the tissue material. The outcome of the model was validated against the experimental measurements before using the model in simplified representations of two surgical procedures. Results: The numerical model was able to reproduce the experimental measurements of specimen deformation and fibril reorientation under uniaxial loading with errors below 8.0%. With tissue removal simulated in a full eye numerical model, fibril reorientation could be predicted around the affected area, and this change both increased with larger tissue removal and reduced gradually away from that area. Conclusion: The presented method can successfully simulate fibril reorientation with changes in the strain regime affecting cornea tissue. Analyses based on this method showed that fibrils tend to align parallel to the tissue cut following keratoplasty operations. With the ability to simulate fibril reorientation, numerical modelling can have a greater potential in modelling the behaviour following surgery and injury to the cornea.

5 February 2025 in JMIR Human Factors
Verified
Journal Article
Open access
SCShao-Hsuan Chang
Shao-Hsuan Chang
DCDaishi Chen
Daishi Chen
CCChi-Sheng Chen
Chi-Sheng Chen
DZDong Zhou
Dong Zhou
LYLung-Kun Yeh
Lung-Kun Yeh
Background: Rhinolaryngoscopes are one of the most widely used tools by otolaryngologists and speech-language pathologists in current clinical practice. However, there is limited data on adverse events associated with or caused by the use of rhinolaryngoscopes. Objective: In this study, we used the Manufacturer and User Facility Device Experience (MAUDE) database with the aim of providing insights that may assist otolaryngologists in better understanding the limitations of these devices and selecting appropriate procedures for their specific clinical setting. Methods: We characterized complications associated with the postmarket use of rhinolaryngoscope devices from the US Food and Drug Administration MAUDE database from 2016 through 2023. Results: A total of 2591 reports were identified, including 2534 device malfunctions, 56 injuries, and 1 death, from 2016 through 2023. The most common device problem with rhinolaryngoscopes was breakage (n=1058 reports, 40.8%), followed by fluid leaks (n=632 reports, 24.4%). The third most common problem was poor image quality (n=467 reports, 18%). Other device issues included contamination or device reprocessing problems (n=127 reports, 4.9%), material deformation or wear (n=125 reports, 4.8%), and device detachment (n=73 reports, 2.8%). Of the 63 reported adverse events, the most common patient-related adverse event was hemorrhage or bleeding, accounting for 18 reports, with the root causes including material deformation or wear, breakage, wrinkled rubber, or improper operation. Conclusions: Our study offers valuable insights for endoscopists and manufacturers to recognize potential issues and adverse events associated with the use of rhinolaryngoscopes. It emphasizes the need for improving device reliability, training, and procedural protocols to enhance patient safety during diagnostic procedures.