Marta Díez-Sotelo

Marta Díez-Sotelo

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MDMarta Díez-Sotelo
Marta Díez-Sotelo
MGMacarena Díaz González
Macarena Díaz González
MAMaximino Abraldes
Maximino Abraldes
FGFrancisco Gómez-Ulla
Francisco Gómez-Ulla
MPManuel F. González Penedo
Manuel F. González Penedo
Marcos OrtegaMarcos Ortega
Marcos Ortega
The assessment of vascular biomarkers and their correlation with visual acuity is one of the most important issues in the diagnosis and follow-up of retinal vein occlusions (RVOs). The high workloads of clinical practice make it necessary to have a fast, objective, and automatic method to analyze image features and correlate them with visual function. The aim of this study is to propose a fully automatic system which is capable of estimating visual acuity (VA) in RVO eyes, based only on information obtained from macular optical coherence tomography angiography (OCTA) images. We also propose an automatic methodology to rapidly measure the foveal avascular zone (FAZ) area and the vascular density (VD) in the superficial and deep capillary plexuses in swept-source OCTA images centered on the fovea. The proposed methodology is validated using a representative sample of 133 visits of 50 RVO patients. Our methodology estimates VA with very high precision and is even more accurate when we integrate depth information, providing a high correlation index of 0.869 with the real VA, which outperforms the correlation index of 0.855 obtained when estimating VA from the data obtained by the semiautomatic existing method. In conclusion, the proposed method is the first computational system able to estimate VA in RVO, with the additional benefits of being automatic, less time-consuming, objective and more accurate. Furthermore, the proposed method is able to integrate depth information, a feature which is lacking in the existing method.

4 December 2019 in Case Reports in Ophthalmology
Verified
Journal Article
Open access
PDF file
MDMarta Díez-Sotelo
Marta Díez-Sotelo
MAMaximino Abraldes
Maximino Abraldes
FGFrancisco Gómez-Ulla
Francisco Gómez-Ulla
Combined central retinal artery and vein occlusion is an uncommon vascular pathology that can cause severe and permanent visual impairment. Optical coherence tomography angiography (OCTA) is a newly available, noninvasive imaging technique that can potentially improve understanding of the structural and vascular implications and prognosis of this infrequent pathology. The present report describes the principal clinical findings in a case of combined central retinal artery and vein occlusion, as detected by the different imaging modalities available in a tertiary referral hospital. OCTA wide-field montage images identified an extensive area of nonperfusion on the macula with involvement of the entire retina at nearly 360°. We observed the most severe nonperfusion in the deep capillary plexus, while perfusion of the choriocapillaris was unaffected. Meanwhile, fluorescein angiography (FA) findings revealed a delay in perfusion rate with marked nonperfusion areas in the peripheral retina at 360°. We identified that the wide-field OCTA montage permitted visualization of a similar or wider peripheral retinal area compared with FA. Therefore, OCTA is potentially useful for assessment of the global retinal nonperfusion status at baseline and during follow-up, with the added advantage of being a noninvasive technique.

31 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MGMacarena Díaz González
Macarena Díaz González
MDMarta Díez-Sotelo
Marta Díez-Sotelo
FGFrancisco Gómez-Ulla
Francisco Gómez-Ulla
Jorge NovoJorge Novo
Jorge Novo
MPManuel F. González Penedo
Manuel F. González Penedo
Marcos OrtegaMarcos Ortega
Marcos Ortega
Optical Coherence Tomography Angiography (OCTA) constitutes a new non-invasive ophthalmic image modality that allows the precise visualization of the micro-retinal vascularity that is commonly used to analyze the foveal region. Given that there are many systemic and eye diseases that affect the eye fundus and its vascularity, the analysis of that region is crucial to diagnose and estimate the vision loss. The Visual Acuity (VA) is typically measured manually, implying an exhaustive and time-consuming procedure. In this work, we propose a method that exploits the information of the OCTA images to automatically estimate the VA with an accurate error of 0.1713.