Eduardo Huerta  Mascotte

Prof. Eduardo Huerta Mascotte


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
EMEduardo Huerta Mascotte
Eduardo Huerta Mascotte
JSJuan Sierra
Juan Sierra
Ruth Ivonne Mata-ChavezRuth Ivonne Mata-Chavez
Ruth Ivonne Mata-Chavez
DJD. Jauregui-Vazquez
D. Jauregui-Vazquez
Arturo Alberto Castillo-GuzmánArturo Alberto Castillo-Guzmán
Arturo Alberto Castillo-Guzmán
RRRoberto Rojas-Laguna
Roberto Rojas-Laguna
In this paper, an all-fiber Mach-Zehnder interferometer (MZI) based on a non-zero dispersion-shifted fiber (NZ-DSF) is presented. The MZI was implemented by core-offset fusion splicing one section of a NZ-DSF fiber between two pieces of single mode fibers (SMFs). Here, the NZ-DSF core and cladding were used as the arms of the MZI, while the core-offset sections acted as optical fiber couplers. Thus, a MZI interference spectrum with a fringe contrast (FC) of about 20 dB was observed. Moreover, its response spectrum was experimentally characterized to the torsion parameter and a sensitivity of 0.070 nm/° was achieved. Finally, these MZIs can be implemented in a compact size and low cost.

4 March 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Ruth Ivonne Mata-ChavezRuth Ivonne Mata-Chavez
Ruth Ivonne Mata-Chavez
AMAlejandro Martinez-Rios
Alejandro Martinez-Rios
JAJulian Moises EstudIllo Ayala
Julian Moises EstudIllo Ayala
EVEverardo Vargas-Rodriguez
Everardo Vargas-Rodriguez
RRRoberto Rojas-Laguna
Roberto Rojas-Laguna
EMEduardo Huerta Mascotte
Eduardo Huerta Mascotte
A compact high temperature fiber sensor where the sensor head consists of a short fattened long period fiber grating (F-LPFG) of at least 2 mm in length and background loss of −5 dBm is reported. On purpose two different F-LPFGs were used to measure temperature variations, taking advantage of their broad spectrum and the slope characteristics of the erbium light source. This approach affected the spectrum gain as the linear band shifting took place. The measured sensitivity of the long period fiber gratings were about 72 pm/°C in a range from 25 to 500 °C. Here, the temperature rate of the experiment was 0.17 °C/s and the temperature response time was within 3 s. Moreover, temperature changes were detected with an InGaAs photodetector, where a sensitivity of 0.05 mV/°C was achieved.