Mustafa Ali ÇİPİLOĞLU

Prof. Mustafa Ali ÇİPİLOĞLU

Manisa Celal Bayar University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2019 in Coatings
Verified
Journal Article
Open access
PDF file
IAIbrahim Aydin
Ibrahim Aydin
ABALİ İHSAN BAHÇEPINAR
ALİ İHSAN BAHÇEPINAR
MKMustafa Kırman
Mustafa Kırman
MÇMustafa Ali ÇİPİLOĞLU
Mustafa Ali ÇİPİLOĞLU
Ti and its alloys, which are commonly used in biomedical applications, are often preferred due to their proximity to the mechanical properties of bone. In order to increase the biocompatibility and bioactivities of these materials, biomaterials based on ceramic are used in coating operations. In this study, by using an electrophoretic deposition method, instead of on the Ti6Al4V alloy which is commonly used in the literature, a hydroxyapatite (HA) coating operation was applied on the surface of the Ti6Al7Nb alloy, and the surface properties of the coatings were examined. Ti6Al7Nb is a new-generation implant on which there have not been many studies. The voltage values which were used in the coating operation were 50, 100, 150 and 200 V, and the time parameter was stabilized at 1 min. In our method, when preparing the solution, HA, ethanol, and polyvinyl alcohol (PVA) were used. At the end of the study, by using an electron microscope (SEM) the microstructures of the coatings were examined; elemental analyses (EDS) of the coating surfaces were performed; and by using an X-radiation diffraction (XRD) method, the phases which the coatings contained and the concentration of these phases were determined, and the coating thickness, roughness, and hardness values were also determined. Also, by conducting a Scratch test, the strength of the surface combination was examined. At the end of the study, in each parameter, a successful HA coating was seen. By comparing parameters with each other, the ideal voltage value in this coating was determined. It was determined that the most suitable coating was obtained at 100 V voltage and 1 min deposition time.

17 July 2020 in Molecules
Verified
Journal Article
Open access
PDF file
MÇMustafa Ali ÇİPİLOĞLU
Mustafa Ali ÇİPİLOĞLU
AÖAli Özkurt
Ali Özkurt
In this study, molecular structure and electronic properties of eleven BxLiy (x = 1–3, y = 1–3) clusters are examined using the Perdew, Burke and Ernezerhof (PBE) method in the Quantum ESPRESSO program. Three main groups, consisting of two atoms, three atoms and four atoms, are selected as the starting points. The stable configurations, their binding energies per atom (Eb), dissociation energy (ΔE), and the second difference in energy (Δ2E), HOMO-LUMO (HOMO: Highest Occupied Molecular Orbital LUMO: Lowest Occupied Molecular Orbital) gaps, total energy, frequency, force on atom, point group, bond length, density of state (DOS) and band structures are investigated for BxLiy (x = 1–3, y = 1–3) clusters. The results of binding energies (Eb), dissociation energy (ΔE) and the second difference in energy (Δ2E) show that BLi, BLi2 first isomer, BLi2 second isomer, B2Li2 first isomer, B2Li2 second isomer and BLi3 are the most stable among all 11 molecules of BxLiy (x = 1–3, y = 1–3). The stability of BxLiy (x = 1–3, y = 1–3) clusters depend on both the formation of geometrical structures on the number of Li atoms. As the number of Li atoms in the group increases, the stability of BxLiy clusters also increases. Within each group formation of geometrical structures, the stability of BxLiy clusters changes. It is observed that they may change the capability of chemical reactions in BxLiy clusters.