Leonardo Rundo

Prof. Leonardo Rundo

DIEM, University of Salerno, Fisciano, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
MYMichael Yeung
Michael Yeung
ESEvis Sala
Evis Sala
CSCarola-Bibiane Schönlieb
Carola-Bibiane Schönlieb
Leonardo RundoLeonardo Rundo
Leonardo Rundo
Automatic segmentation methods are an important advancement in medical image analysis. Machine learning techniques, and deep neural networks in particular, are the state-of-the-art for most medical image segmentation tasks. Issues with class imbalance pose a significant challenge in medical datasets, with lesions often occupying a considerably smaller volume relative to the background. Loss functions used in the training of deep learning algorithms differ in their robustness to class imbalance, with direct consequences for model convergence. The most commonly used loss functions for segmentation are based on either the cross entropy loss, Dice loss or a combination of the two. We propose the Unified Focal loss, a new hierarchical framework that generalises Dice and cross entropy-based losses for handling class imbalance. We evaluate our proposed loss function on five publicly available, class imbalanced medical imaging datasets: CVC-ClinicDB, Digital Retinal Images for Vessel Extraction (DRIVE), Breast Ultrasound 2017 (BUS2017), Brain Tumour Segmentation 2020 (BraTS20) and Kidney Tumour Segmentation 2019 (KiTS19). We compare our loss function performance against six Dice or cross entropy-based loss functions, across 2D binary, 3D binary and 3D multiclass segmentation tasks, demonstrating that our proposed loss function is robust to class imbalance and consistently outperforms the other loss functions. Source code is available at: https://github.com/mlyg/unified-focal-loss.

1 March 2021 in Physica Medica
Verified
Journal Article
Closed access
ICIsabella Castiglioni
Isabella Castiglioni
Leonardo RundoLeonardo Rundo
Leonardo Rundo
MCMarina Codari
Marina Codari
GLGiovanni Di Leo
Giovanni Di Leo
CSChristian Salvatore
Christian Salvatore
FSFrancesco Sardanelli
Francesco Sardanelli

1 November 2019 in Neurocomputing
Verified
Journal Article
Open access
Leonardo RundoLeonardo Rundo
Leonardo Rundo
CHChanghee Han
Changhee Han
YNYudai Nagano
Yudai Nagano
JZJin Zhang
Jin Zhang
RHRyuichiro Hataya
Ryuichiro Hataya
PCPaolo Cazzaniga
Paolo Cazzaniga

1 April 2018
Verified
Conference Paper
Closed access
CHChanghee Han
Changhee Han
HHHideaki Hayashi
Hideaki Hayashi
Leonardo RundoLeonardo Rundo
Leonardo Rundo
RARyosuke Araki
Ryosuke Araki
WSWataru Shimoda
Wataru Shimoda
HNHideki Nakayama
Hideki Nakayama
In medical imaging, it remains a challenging and valuable goal how to generate realistic medical images completely different from the original ones; the obtained synthetic images would improve diagnostic reliability, allowing for data augmentation in computer-assisted diagnosis as well as physician training. In this paper, we focus on generating synthetic multi-sequence brain Magnetic Resonance (MR) images using Generative Adversarial Networks (GANs). This involves difficulties mainly due to low contrast MR images, strong consistency in brain anatomy, and intra-sequence variability. Our novel realistic medical image generation approach shows that GANs can generate 128 χ 128 brain MR images avoiding artifacts. In our preliminary validation, even an expert physician was unable to accurately distinguish the synthetic images from the real samples in the Visual Turing Test.

15 October 2019 in IEEE Access
Verified
Journal Article
Open access
Changhee HanChanghee Han
Changhee Han
Leonardo RundoLeonardo Rundo
Leonardo Rundo
RARyosuke Araki
Ryosuke Araki
YNYudai Nagano
Yudai Nagano
YFYujiro Furukawa
Yujiro Furukawa
HHHideaki Hayashi
Hideaki Hayashi

1 October 2021 in Computers in Biology and Medicine
Verified
Journal Article
Open access
MYMichael Yeung
Michael Yeung
ESEvis Sala
Evis Sala
CSCarola-Bibiane Schönlieb
Carola-Bibiane Schönlieb
Leonardo RundoLeonardo Rundo
Leonardo Rundo
Colonoscopy remains the gold-standard screening for colorectal cancer. However, significant miss rates for polyps have been reported, particularly when there are multiple small adenomas. This presents an opportunity to leverage computer-aided systems to support clinicians and reduce the number of polyps missed. In this work we introduce the Focus U-Net, a novel dual attention-gated deep neural network, which combines efficient spatial and channel-based attention into a single Focus Gate module to encourage selective learning of polyp features. The Focus U-Net incorporates several further architectural modifications, including the addition of short-range skip connections and deep supervision. Furthermore, we introduce the Hybrid Focal loss, a new compound loss function based on the Focal loss and Focal Tversky loss, designed to handle class-imbalanced image segmentation. For our experiments, we selected five public datasets containing images of polyps obtained during optical colonoscopy: CVC-ClinicDB, Kvasir-SEG, CVC-ColonDB, ETIS-Larib PolypDB and EndoScene test set. We first perform a series of ablation studies and then evaluate the Focus U-Net on the CVC-ClinicDB and Kvasir-SEG datasets separately, and on a combined dataset of all five public datasets. To evaluate model performance, we use the Dice similarity coefficient (DSC) and Intersection over Union (IoU) metrics. Our model achieves state-of-the-art results for both CVC-ClinicDB and Kvasir-SEG, with a mean DSC of 0.941 and 0.910, respectively. When evaluated on a combination of five public polyp datasets, our model similarly achieves state-of-the-art results with a mean DSC of 0.878 and mean IoU of 0.809, a 14% and 15% improvement over the previous state-of-the-art results of 0.768 and 0.702, respectively. This study shows the potential for deep learning to provide fast and accurate polyp segmentation results for use during colonoscopy. The Focus U-Net may be adapted for future use in newer non-invasive colorectal cancer screening and more broadly to other biomedical image segmentation tasks similarly involving class imbalance and requiring efficiency.