Phillipe Mertens

Phillipe Mertens

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2002 in Journal of Physics B: Atomic, Molecular and Optical Physics
Verified
Journal Article
Closed access
PDF file
JHJ D Hey
J D Hey
CCC C Chu
C C Chu
SBSebastijan Brezinsek
Sebastijan Brezinsek
PMPhillipe Mertens
Phillipe Mertens
BUB Unterberg
B Unterberg

1 October 2015 in Fusion Engineering and Design
Verified
Journal Article
Closed access
AHAlexander Huber
Alexander Huber
MWMarius Wirtz
Marius Wirtz
GSGennady Sergienko
Gennady Sergienko
ISIsabel Steudel
Isabel Steudel
AAAleksey Arakcheev
Aleksey Arakcheev
BUBernhard Unterberg
Bernhard Unterberg

1 January 2019 in Nuclear Materials and Energy
Verified
Journal Article
Open access
AHAlexander Huber
Alexander Huber
SBSebastijan Brezinsek
Sebastijan Brezinsek
AKA. Kirschner
A. Kirschner
PSP. Ström
P. Ström
GSGennady Sergienko
Gennady Sergienko
PMP.H. Mertens
P.H. Mertens

1 November 2017 in Fusion Engineering and Design
Verified
Journal Article
Open access
AHAlexander Huber
Alexander Huber
GSGennady Sergienko
Gennady Sergienko
DKDavid Kinna
David Kinna
VHValentina Huber
Valentina Huber
AMAlberto Milocco
Alberto Milocco
KZKlaus-Dieter Zastrow
Klaus-Dieter Zastrow
The analysis of the radiation damage of imaging systems is based on all different types of analogue/digital cameras with uncooled as well as actively cooled image sensors in the VIS/NIR/MWIR spectral ranges. The Monte Carlo N-Particle (MCNP) code has been used to determine the neutron fluence at different camera locations in JET. An explicit link between the sensor damage and the neutron fluence has been observed. Sensors show an increased dark-current and increased numbers of hot-pixels. Uncooled cameras must be replaced once per year after exposure to a neutron fluence of ∼1.9–3.2 × 1012neutrons/cm2. Such levels of fluence will be reached after ≈14-22 ELMy H-mode pulses during the future D-T campaign. Furthermore, dynamical noise seen as a random pattern of bright pixels was observed in the presence of hard radiation (neutrons and gammas). Failure of the digital electronics inside the cameras as well as of industrial controllers is observed beyond a neutron fluence of about ∼4 × 109 neutrons/cm2. The impact of hard radiation on the different types of electronics and possible application of cameras during future D-T campaign is discussed

19 November 2018 in Journal of Fusion Energy
Verified
Journal Article
Closed access
PDF file
PMPhilippe Mertens
Philippe Mertens

1 September 2019 in Fusion Engineering and Design
Verified
Journal Article
Closed access
PMPhilippe Mertens
Philippe Mertens
RBRomain Boman
Romain Boman
SDSven Oliver Dickheuer
Sven Oliver Dickheuer
YKYury Krasikov
Yury Krasikov
AKAndreas Krimmer
Andreas Krimmer
MBMaarten De Bock
Maarten De Bock