Martyn A.C. Wilkinson

Martyn A.C. Wilkinson

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2013 in Journal of Hospital Infection
Verified
Journal Article
Closed access
AFA.P. Fraise
A.P. Fraise
MWMartyn A.C. Wilkinson
Martyn A.C. Wilkinson
CBC.R. Bradley
C.R. Bradley
BOB. Oppenheim
B. Oppenheim
Naiem MoiemenNaiem Moiemen
Naiem Moiemen

1 December 2015 in Journal of Hospital Infection
Verified
Journal Article
Closed access
SSS.A. Sattar
S.A. Sattar
CBC. Bradley
C. Bradley
RKR. Kibbee
R. Kibbee
RWR. Wesgate
R. Wesgate
MWMartyn A.C. Wilkinson
Martyn A.C. Wilkinson
JMJean-Yves Maillard
Jean-Yves Maillard

3 August 2012 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
GMGinny Moore
Ginny Moore
SAShanom Ali
Shanom Ali
ECElaine Cloutman-Green
Elaine Cloutman-Green
CBChristina R Bradley
Christina R Bradley
MWMartyn A.C. Wilkinson
Martyn A.C. Wilkinson
AWA Peter R Wilson
A Peter R Wilson
The near-patient environment is often heavily contaminated, yet the decontamination of near-patient surfaces and equipment is often poor. The Nanoclave Cabinet produces large amounts of ultraviolet-C (UV-C) radiation (53 W/m2) and is designed to rapidly disinfect individual items of clinical equipment. Controlled laboratory studies were conducted to assess its ability to eradicate a range of potential pathogens including Clostridium difficile spores and Adenovirus from different types of surface.

5 March 2019 in Journal of Infection Prevention
Verified
Journal Article
Open access
PDF file
ECEvonne T Curran
Evonne T Curran
MWMartyn A.C. Wilkinson
Martyn A.C. Wilkinson
TBTina Bradley
Tina Bradley
In recent years, the number of disinfectants designed to decontaminate healthcare environments and reusable, non-invasive care equipment (NICE) has increased markedly, making the selection of the most appropriate disinfectant a somewhat daunting prospect. In addition to the microbial challenge, there are numerous factors to consider including: efficacy; range and speed of activity; stability of the ingredients; compatibility of the disinfectant with surfaces; inactivation of the disinfectant by organic matter; method of application; convenience; health and safety concerns; and cost. While the microbial challenge continues to evolve, and novel disinfectants continue to emerge, guidance updates have been notably absent. Most healthcare surfaces belong to a UK-defined category of ‘low risk’ for which guidance dictates ‘cleaning and drying is usually sufficient’. This paper assesses the evidence and arguments regarding the use of disinfectants for low-risk healthcare surfaces. A novel subcategorisation of ‘low risk’ is presented to provide a more specific up-to-date disinfectant needs assessment.

1 February 2017 in Journal of Hospital Infection
Verified
Journal Article
Closed access
MWMartyn A.C. Wilkinson
Martyn A.C. Wilkinson
KOK. Ormandy
K. Ormandy
CBC.R. Bradley
C.R. Bradley
AFA.P. Fraise
A.P. Fraise
JHJ. Hines
J. Hines

19 December 2017 in Antimicrobial Resistance & Infection Control
Verified
Journal Article
Open access
PDF file
MGMark I. Garvey
Mark I. Garvey
CBCraig W. Bradley
Craig W. Bradley
MWMartyn A.C. Wilkinson
Martyn A.C. Wilkinson
EHElisabeth Holden
Elisabeth Holden
Diagnosis of C. difficile infection (CDI) is controversial because of the many laboratory methods available and their lack of ability to distinguish between carriage, mild or severe disease. Here we describe whether a low C. difficile toxin B nucleic acid amplification test (NAAT) cycle threshold (CT) can predict toxin EIA, CDI severity and mortality. A three-stage algorithm was employed for CDI testing, comprising a screening test for glutamate dehydrogenase (GDH), followed by a NAAT, then a toxin enzyme immunoassay (EIA). All diarrhoeal samples positive for GDH and NAAT between 2012 and 2016 were analysed. The performance of the NAAT CT value as a classifier of toxin EIA outcome was analysed using a ROC curve; patient mortality was compared to CTs and toxin EIA via linear regression models. A CT value ≤26 was associated with ≥72% toxin EIA positivity; applying a logistic regression model we demonstrated an association between low CT values and toxin EIA positivity. A CT value of ≤26 was significantly associated (p = 0.0262) with increased one month mortality, severe cases of CDI or failure of first line treatment. The ROC curve probabilities demonstrated a CT cut off value of 26.6. Here we demonstrate that a CT ≤26 indicates more severe CDI and is associated with higher mortality. Samples with a low CT value are often toxin EIA positive, questioning the need for this additional EIA test. A CT ≤26 could be used to assess the potential for severity of CDI and guide patient treatment.